Hybrid fast damping control strategy for doubly fed induction generators against power system inter-area oscillations

被引:6
|
作者
Liao, Kai [1 ]
Xu, Yan [1 ]
Wang, Yao [2 ]
He, Zhengyou [3 ]
Marzooghi, Hesamoddin [4 ]
机构
[1] Nanyang Technol Univ, Sch Elect & Elect Engn, 50 Nanyang Ave, Singapore, Singapore
[2] Southwest Minzu Univ, Sch Elect & Informat Engn, Chengdu 610041, Sichuan, Peoples R China
[3] Southwest Jiaotong Univ, Sch Elect Engn, Chengdu 611756, Sichuan, Peoples R China
[4] CQ Univ, Sch Engn & Technol, Brisbane, Qld 4000, Australia
关键词
asynchronous generators; power system stability; bang-bang control; reactive power control; frequency-domain analysis; wind power plants; power generation control; hybrid fast damping control strategy; doubly fed induction generators; power system inter-area oscillations; bang-bang modulation; inter-area oscillations; active power modulation; torsional oscillations; DFIG reactive power; system critical oscillation mode; detected critical oscillation mode; lead phase; frequency domain analysis; detailed dynamic model; comprehensive test; modified two-area system; aggregated wind farm; operation point variation; identification errors; WIND GENERATION; TURBINES; SIGNALS;
D O I
10.1049/iet-rpg.2017.0196
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Here, a hybrid fast damping control strategy based on bang-bang modulation is proposed for doubly fed induction generators (DFIGs) against inter-area oscillations. Since the changes in active power modulation of DFIG may result in its interactive effect with torsional oscillations, this study relies on the modulation of DFIG reactive power to rapidly attenuate the system's critical oscillation mode. In order to overcome the buffeting of the bang-bang modulation, the proposed control strategy is designed as a hybrid scheme consisting of three operating modes which are switched based on the amplitude of the detected critical oscillation mode. The required lead phase for the proposed control strategy is determined using frequency domain analysis using detailed dynamic model of the DFIG. A comprehensive test is carried out by conducting simulation studies on a modified two-area system including an aggregated wind farm. It has been shown that the proposed strategy damps inter-area oscillations much quicker than the conventional continuous damping controller. Simulation results also showed that the control scheme is robust to the operation point variation and identification errors for practical application.
引用
收藏
页码:463 / 471
页数:9
相关论文
共 50 条
  • [11] Damping control of inter-area oscillations in the European power system using aggregated models
    Kussner, K.
    Kasztel, Z.
    Erlich, I.
    Wilfert, H.-H.
    Schegner, P.
    Electrical Engineering, 2001, 83 (1-6) : 275 - 285
  • [12] Damping Inter-Area Oscillations in Power Systems by STATCOMs
    Zarghami, Mahyar
    Crow, Mariesa. L.
    2008 40TH NORTH AMERICAN POWER SYMPOSIUM (NAPS 2008), 2008, : 255 - 260
  • [13] Sliding controller for damping inter-area power oscillations
    Pourboghrat, F
    Mehdian, F
    COMPUTERS & ELECTRICAL ENGINEERING, 2002, 28 (06) : 599 - 610
  • [14] A Coordinated Dual-Channel Wide Area Damping Control Strategy for a Doubly-Fed Induction Generator Used for Suppressing Inter-Area Oscillation
    Cai, Guowei
    Chen, Xiangsong
    Sun, Zhenglong
    Yang, Deyou
    Liu, Cheng
    Li, Haobo
    APPLIED SCIENCES-BASEL, 2019, 9 (11):
  • [15] Dynamic Control Allocation for Damping of Inter-Area Oscillations
    Raoufat, M. Ehsan
    Tomsovic, Kevin
    Djouadi, Seddik M.
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2017, 32 (06) : 4894 - 4903
  • [16] A study on LQG/LTR control for damping inter-area oscillations in power systems
    Zolotas, Argyrios C.
    Chaudhuri, Balarko
    Jaimoukha, Imad M.
    Korba, Petr
    IEEE TRANSACTIONS ON CONTROL SYSTEMS TECHNOLOGY, 2007, 15 (01) : 151 - 160
  • [17] Analysis of a Centralized Control Strategy in Mitigating Inter-Area Power Oscillations
    Maki, Otso
    Seppanen, Janne
    Haarla, Liisa
    Zenger, Kai
    Turunen, Jukka
    Nikkila, Antti-Juhani
    2014 IEEE PES INNOVATIVE SMART GRID TECHNOLOGIES CONFERENCE EUROPE (ISGT EUROPE), 2014,
  • [18] Variable Power Tracking Control Strategy of Doubly Fed Induction Generators for Fast Frequency Responses
    Xue, Xiaocen
    Huang, Jiejie
    Sang, Shun
    ELECTRONICS, 2024, 13 (06)
  • [19] An investigation on the use of power system stabilizers for damping inter-area oscillations in longitudinal power system
    Messina, AR
    Ramirez, JM
    Canedo, JM
    IEEE TRANSACTIONS ON POWER SYSTEMS, 1998, 13 (02) : 552 - 558
  • [20] Damping of inter-area mode oscillations with high penetration of the Power System in Wind
    Gallardo Q., Carlos F.
    Pablo Ledesma, L.
    IECON 2008: 34TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, VOLS 1-5, PROCEEDINGS, 2008, : 2066 - 2071