Hybrid fast damping control strategy for doubly fed induction generators against power system inter-area oscillations

被引:6
|
作者
Liao, Kai [1 ]
Xu, Yan [1 ]
Wang, Yao [2 ]
He, Zhengyou [3 ]
Marzooghi, Hesamoddin [4 ]
机构
[1] Nanyang Technol Univ, Sch Elect & Elect Engn, 50 Nanyang Ave, Singapore, Singapore
[2] Southwest Minzu Univ, Sch Elect & Informat Engn, Chengdu 610041, Sichuan, Peoples R China
[3] Southwest Jiaotong Univ, Sch Elect Engn, Chengdu 611756, Sichuan, Peoples R China
[4] CQ Univ, Sch Engn & Technol, Brisbane, Qld 4000, Australia
关键词
asynchronous generators; power system stability; bang-bang control; reactive power control; frequency-domain analysis; wind power plants; power generation control; hybrid fast damping control strategy; doubly fed induction generators; power system inter-area oscillations; bang-bang modulation; inter-area oscillations; active power modulation; torsional oscillations; DFIG reactive power; system critical oscillation mode; detected critical oscillation mode; lead phase; frequency domain analysis; detailed dynamic model; comprehensive test; modified two-area system; aggregated wind farm; operation point variation; identification errors; WIND GENERATION; TURBINES; SIGNALS;
D O I
10.1049/iet-rpg.2017.0196
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Here, a hybrid fast damping control strategy based on bang-bang modulation is proposed for doubly fed induction generators (DFIGs) against inter-area oscillations. Since the changes in active power modulation of DFIG may result in its interactive effect with torsional oscillations, this study relies on the modulation of DFIG reactive power to rapidly attenuate the system's critical oscillation mode. In order to overcome the buffeting of the bang-bang modulation, the proposed control strategy is designed as a hybrid scheme consisting of three operating modes which are switched based on the amplitude of the detected critical oscillation mode. The required lead phase for the proposed control strategy is determined using frequency domain analysis using detailed dynamic model of the DFIG. A comprehensive test is carried out by conducting simulation studies on a modified two-area system including an aggregated wind farm. It has been shown that the proposed strategy damps inter-area oscillations much quicker than the conventional continuous damping controller. Simulation results also showed that the control scheme is robust to the operation point variation and identification errors for practical application.
引用
收藏
页码:463 / 471
页数:9
相关论文
共 50 条
  • [1] Doubly fed induction generators to enhance inter-area damping based on a Robust controller: H2/H∞ Control
    Goodarzi, Ali
    Ranjbar, Ali Mohammad
    Dehghani, Moslem
    GhasemiGarpachi, Mina
    Ghiasi, Mohammad
    SN APPLIED SCIENCES, 2021, 3 (01):
  • [2] Decentralized Servomechanism Control Design for Inter-Area Oscillations Damping in Power System
    Biroon, Roghieh A.
    Pisu, Pierluigi
    Schoenwald, David
    2019 51ST NORTH AMERICAN POWER SYMPOSIUM (NAPS), 2019,
  • [3] A Novel Emergency Damping Control to Suppress Power System Inter-Area Oscillations
    Cao, Jun
    Du, Wenjuan
    Wang, Haifeng
    Chen, Z.
    Li, H. F.
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2013, 28 (03) : 3165 - 3173
  • [4] Damping Control of a Power System with DFIG Based on MPC for Inter-area Oscillations
    Sun, Lu
    Yu, Siyao
    Diao, Shuo
    Zhang, Haoxin
    2021 3RD ASIA ENERGY AND ELECTRICAL ENGINEERING SYMPOSIUM (AEEES 2021), 2021, : 611 - 615
  • [5] Local sliding control for damping inter-area power oscillations
    Pourboghrat, F
    Farid, F
    Hatziadoniu, C
    Daneshdoost, M
    Mehdian, F
    Lotfalian, M
    2004 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1 AND 2, 2004, : 1710 - 1710
  • [6] Adaptive Wide Area Damping Controller for Damping Inter-Area Oscillations On Power System
    Ranjbar, Soheil
    Haghjoo, Farhad
    Aghamohammadi, Mohammad Reza
    2016 24TH IRANIAN CONFERENCE ON ELECTRICAL ENGINEERING (ICEE), 2016, : 1609 - 1614
  • [7] Effects of Wind Turbine Generators on Inter-Area Oscillations and Damping Control Design
    Wilches-Bernal, Felipe
    Lackner, Christoph
    Chow, Joe H.
    Sanchez-Gasca, Juan J.
    PROCEEDINGS OF THE 52ND ANNUAL HAWAII INTERNATIONAL CONFERENCE ON SYSTEM SCIENCES, 2019, : 3649 - 3658
  • [8] Damping control of inter-area oscillations in the European power system using aggregated models
    Küssner, K
    Kasztel, Z
    Erlich, I
    Wilfert, HH
    Schegner, P
    ELECTRICAL ENGINEERING, 2001, 83 (5-6) : 275 - 285
  • [9] Damping control of inter-area oscillations in the European power system using aggregated models
    K. Küßner
    Z. Kasztel
    I. Erlich
    H.-H. Wilfert
    P. Schegner
    Electrical Engineering, 2001, 83 : 275 - 285
  • [10] A genetic-based control design for damping power system inter-area oscillations
    Taranto, GN
    Falcao, DM
    PROCEEDINGS OF THE 35TH IEEE CONFERENCE ON DECISION AND CONTROL, VOLS 1-4, 1996, : 4389 - 4394