Benchmarking of a motion sensing system for medical imaging and radiotherapy

被引:13
作者
Barnes, Peter J. [1 ]
Baldock, Clive [1 ]
Meikle, Steven R. [2 ,3 ]
Fulton, Roger R. [1 ,2 ,3 ,4 ]
机构
[1] Univ Sydney, Sch Phys A28, Inst Med Phys, Sydney, NSW 2006, Australia
[2] Univ Sydney, Discipline Med Radiat Sci & Brain, Sydney, NSW 2006, Australia
[3] Univ Sydney, Mind Res Inst, Sydney, NSW 2006, Australia
[4] Westmead Hosp, Dept Med Phys, Sydney, NSW, Australia
关键词
D O I
10.1088/0031-9155/53/20/019
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We have tested the performance of an Optotrak Certus system, which optically tracks multiple markers, in both position and time. To do this, we have developed custom code which enables a range of testing protocols, and make this code available to the community. We find that the Certus' positional accuracy is very high, around 20 mu m at a distance of 2.8 m. In contrast, we find that its timing accuracy is typically no better than around 5-10% for typical data rates, whether one is using an ethernet connection or a dedicated SCSI link from the system to a host computer. However, with our code we are able to attach very accurate timestamps to the data frames, and in cases where regularly-spaced data are not an absolute requirement, this will be more than adequate.
引用
收藏
页码:5845 / 5857
页数:13
相关论文
共 24 条
  • [1] BARNES P, 2006, AUSTRALAS PHYS ENG S, V29, P397
  • [2] Towards fluoroscopic respiratory gating for lung tumours without radiopaque markers
    Berbeco, RI
    Mostafavi, H
    Sharp, GC
    Jiang, SB
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (19) : 4481 - 4490
  • [3] A technique for respiratory-gated radiotherapy treatment verification with an EPID in cine mode
    Berbeco, RI
    Neicu, T
    Rietzel, E
    Chen, GTY
    Jiang, SB
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (16) : 3669 - 3679
  • [4] Residual motion of lung tumors in end-of-inhale respiratory gated radiotherapy based on external surrogates
    Berbeco, Ross I.
    Nishioka, Seiko
    Shirato, Hiroki
    Jiang, Steve B.
    [J]. MEDICAL PHYSICS, 2006, 33 (11) : 4149 - 4156
  • [5] The design and implementation of a motion correction scheme for neurological PET
    Bloomfield, PM
    Spinks, TJ
    Reed, J
    Schnorr, L
    Westrip, AM
    Livieratos, L
    Fulton, R
    Jones, T
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (08) : 959 - 978
  • [6] Respiratory gating in positron emission tomography:: A quantitative comparison of different gating schemes
    Dawood, Mohammad
    Buether, Florian
    Lang, Norbert
    Schober, Otmar
    Schaefers, Klaus P.
    [J]. MEDICAL PHYSICS, 2007, 34 (07) : 3067 - 3076
  • [7] Compensation for respiratory motion by gated radiotherapy:: an experimental study
    Dietrich, L
    Tücking, T
    Nill, S
    Oelfke, U
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (10) : 2405 - 2414
  • [8] Correction for head movements in positron emission tomography using an optical motion-tracking system
    Fulton, RR
    Meikle, SR
    Eberl, S
    Pfeiffer, J
    Constable, CJ
    Fulham, MJ
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (01) : 116 - 123
  • [9] The correlation between internal and external markers for abdominal tumors: Implications for respiratory gating
    Gierga, DP
    Brewer, J
    Sharp, GC
    Betke, M
    Willett, CG
    Chen, GTY
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 61 (05): : 1551 - 1558
  • [10] Design and application of an assessment protocol for electromagnetic tracking systems
    Hummel, JB
    Bax, MR
    Figl, ML
    Kang, Y
    Maurer, C
    Birkfellner, WW
    Bergmann, H
    Shahidi, R
    [J]. MEDICAL PHYSICS, 2005, 32 (07) : 2371 - 2379