Benchmarking of a motion sensing system for medical imaging and radiotherapy

被引:13
作者
Barnes, Peter J. [1 ]
Baldock, Clive [1 ]
Meikle, Steven R. [2 ,3 ]
Fulton, Roger R. [1 ,2 ,3 ,4 ]
机构
[1] Univ Sydney, Sch Phys A28, Inst Med Phys, Sydney, NSW 2006, Australia
[2] Univ Sydney, Discipline Med Radiat Sci & Brain, Sydney, NSW 2006, Australia
[3] Univ Sydney, Mind Res Inst, Sydney, NSW 2006, Australia
[4] Westmead Hosp, Dept Med Phys, Sydney, NSW, Australia
关键词
D O I
10.1088/0031-9155/53/20/019
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We have tested the performance of an Optotrak Certus system, which optically tracks multiple markers, in both position and time. To do this, we have developed custom code which enables a range of testing protocols, and make this code available to the community. We find that the Certus' positional accuracy is very high, around 20 mu m at a distance of 2.8 m. In contrast, we find that its timing accuracy is typically no better than around 5-10% for typical data rates, whether one is using an ethernet connection or a dedicated SCSI link from the system to a host computer. However, with our code we are able to attach very accurate timestamps to the data frames, and in cases where regularly-spaced data are not an absolute requirement, this will be more than adequate.
引用
收藏
页码:5845 / 5857
页数:13
相关论文
共 24 条
[1]  
BARNES P, 2006, AUSTRALAS PHYS ENG S, V29, P397
[2]   Towards fluoroscopic respiratory gating for lung tumours without radiopaque markers [J].
Berbeco, RI ;
Mostafavi, H ;
Sharp, GC ;
Jiang, SB .
PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (19) :4481-4490
[3]   A technique for respiratory-gated radiotherapy treatment verification with an EPID in cine mode [J].
Berbeco, RI ;
Neicu, T ;
Rietzel, E ;
Chen, GTY ;
Jiang, SB .
PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (16) :3669-3679
[4]   Residual motion of lung tumors in end-of-inhale respiratory gated radiotherapy based on external surrogates [J].
Berbeco, Ross I. ;
Nishioka, Seiko ;
Shirato, Hiroki ;
Jiang, Steve B. .
MEDICAL PHYSICS, 2006, 33 (11) :4149-4156
[5]   The design and implementation of a motion correction scheme for neurological PET [J].
Bloomfield, PM ;
Spinks, TJ ;
Reed, J ;
Schnorr, L ;
Westrip, AM ;
Livieratos, L ;
Fulton, R ;
Jones, T .
PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (08) :959-978
[6]   Respiratory gating in positron emission tomography:: A quantitative comparison of different gating schemes [J].
Dawood, Mohammad ;
Buether, Florian ;
Lang, Norbert ;
Schober, Otmar ;
Schaefers, Klaus P. .
MEDICAL PHYSICS, 2007, 34 (07) :3067-3076
[7]   Compensation for respiratory motion by gated radiotherapy:: an experimental study [J].
Dietrich, L ;
Tücking, T ;
Nill, S ;
Oelfke, U .
PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (10) :2405-2414
[8]   Correction for head movements in positron emission tomography using an optical motion-tracking system [J].
Fulton, RR ;
Meikle, SR ;
Eberl, S ;
Pfeiffer, J ;
Constable, CJ ;
Fulham, MJ .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (01) :116-123
[9]   The correlation between internal and external markers for abdominal tumors: Implications for respiratory gating [J].
Gierga, DP ;
Brewer, J ;
Sharp, GC ;
Betke, M ;
Willett, CG ;
Chen, GTY .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 61 (05) :1551-1558
[10]   Design and application of an assessment protocol for electromagnetic tracking systems [J].
Hummel, JB ;
Bax, MR ;
Figl, ML ;
Kang, Y ;
Maurer, C ;
Birkfellner, WW ;
Bergmann, H ;
Shahidi, R .
MEDICAL PHYSICS, 2005, 32 (07) :2371-2379