Apertured impedance microchips: Surface modification and evaluation using high performance liquid chromatography

被引:1
|
作者
Suganuma, Yoshinori [1 ]
Menard, Frederic [1 ]
Lautens, Mark [1 ]
Dhirani, Al-Amin [1 ]
机构
[1] Univ Toronto, Dept Chem, Toronto, ON M5S 3H6, Canada
来源
关键词
Impedance detection; Dielectric constant detection; Capacitive sensors; Surface functionalization; Microfluidics; High performance liquid chromatography (HPLC); CAPACITANCE PROBE; SILICON-OXIDE; REAL-TIME; OIL; WATER; FUNCTIONALIZATION; MONOLAYERS; ALUMINUM; SENSOR; OCTADECYLSILOXANE;
D O I
10.1016/j.snb.2012.07.113
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The present study evaluates the performance and potential utility of apertured impedance microchips (AIMs). The electronics-based, dielectric constant detection devices feature a novel layered architecture with aluminum metal/silicon-oxide/silicon layers, where the top metal layer has apertures and the middle oxide layer has wells. This layered yet open geometry enables molecules to have access to detection of electric fields induced by a voltage applied between the top metal/bottom silicon electrode layers. Our design rationale surmised that the AIM device's large footprint area and thin nanoscale oxide layer should enable impedance detection of molecules with high sensitivity in a variety of solvents. The present study confirms this hypothesis and explores the effects that simple surface modifications have on the device's response. Specifically, the affinity between various analytes and the device's surface is evaluated when: (a) the aluminum top electrode is hydrated and rendered hydrophilic by immersing the microchip in boiling water, and (b) the silicon substrate is stripped of oxide and rendered hydrophobic (hydrogen-terminated) by hydrofluoric acid (HF) wet etching. Both types of devices were incorporated into a high performance liquid chromatography (HPLC) system already equipped with an ultra-violet-visible (UV-vis) detector. A range of analytes was injected using both normal and reverse phase modes; and the signals generated by each microchip device and UV-vis detector were recorded simultaneously and compared. The microchip devices' responses were found to vary for analytes according to the surface modification used. The second surface modification method of exposing bare silicon surface showed greater sensitivity than the first method for all the analytes. Both types of devices were remarkably sensitive to organic salts tested, i.e., their sensitivity was significantly greater than that of the UV-vis detector. To demonstrate the novel dielectric constant capability of AIM, as a case study, the HF-treated device was used to detect enantiomers of a synthesized chiral molecule separated by a chiral column using an insulating eluent, namely hexanes/isopropanol. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:852 / 861
页数:10
相关论文
共 50 条
  • [31] EVALUATION OF THE QUALITY OF ANGELICA SINENSIS BY HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY
    Wang, Zhenzhong
    Shao, Shijun
    ANALYTICAL LETTERS, 2014, 47 (18) : 2857 - 2870
  • [32] Surface modification method of microchannels for gas-liquid two-phase flow in microchips
    Hibara, A
    Iwayama, S
    Matsuoka, S
    Ueno, M
    Kikutani, Y
    Tokeshi, M
    Kitamori, T
    ANALYTICAL CHEMISTRY, 2005, 77 (03) : 943 - 947
  • [33] PURITY EVALUATION OF APROTININ BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    DIMOV, N
    SIMEONOV, S
    BIOMEDICAL CHROMATOGRAPHY, 1993, 7 (03) : 146 - 148
  • [34] Uncertainty evaluation for determining deoxynivalenol in wheat by high performance liquid chromatography
    Shao, Liangliang
    Zhao, Meifeng
    Ning, Hui
    Ying, Meirong
    Luo, Qian
    Yuan, Xiangxing
    Shipin Kexue/Food Science, 2016, 37 (12): : 232 - 237
  • [35] Evaluation of denaturing high performance liquid chromatography (DHPLC) in the analysis of hemophilia A
    Oldenburg, J
    El-Maarri, O
    Ivaskevicius, V
    Rost, S
    Weber, BHF
    Schwaab, R
    31ST HEMOPHILIA SYMPOSIUM: HAMBURG 2000, 2002, : 130 - 140
  • [36] Quantitative evaluation of selenium contained in tea by high performance liquid chromatography
    Yoshida, M
    Kimura, Y
    Abe, M
    Ando, T
    Tachi, H
    Fukunaga, K
    JOURNAL OF NUTRITIONAL SCIENCE AND VITAMINOLOGY, 2001, 47 (03) : 248 - 252
  • [38] Evaluation of the use of microemulsions as eluents in high-performance liquid chromatography
    El-Sherbiny, DTM
    El-Ashrya, SM
    Mustafa, MA
    El-Emam, AA
    Hansen, SH
    JOURNAL OF SEPARATION SCIENCE, 2003, 26 (6-7) : 503 - 509
  • [39] Evaluation of Drug Interaction in Binding to Protein by High Performance Liquid Chromatography
    LI Famei GUO Xingjie QIAO Mingxi XIONG Zhili ZHOU Dawei Shenyang Pharmaceutical University Shenyang China
    色谱, 2004, (04) : 349 - 353
  • [40] In vitro evaluation of antioxidant activity by electrophoresis and high performance liquid chromatography
    Grippa, E
    Pavone, F
    Gatto, MT
    Petrucci, R
    Marrosu, G
    Silvestrini, B
    Saso, L
    BIOCHIMICA ET BIOPHYSICA ACTA-GENERAL SUBJECTS, 2000, 1524 (2-3): : 171 - 177