Apertured impedance microchips: Surface modification and evaluation using high performance liquid chromatography

被引:1
|
作者
Suganuma, Yoshinori [1 ]
Menard, Frederic [1 ]
Lautens, Mark [1 ]
Dhirani, Al-Amin [1 ]
机构
[1] Univ Toronto, Dept Chem, Toronto, ON M5S 3H6, Canada
来源
关键词
Impedance detection; Dielectric constant detection; Capacitive sensors; Surface functionalization; Microfluidics; High performance liquid chromatography (HPLC); CAPACITANCE PROBE; SILICON-OXIDE; REAL-TIME; OIL; WATER; FUNCTIONALIZATION; MONOLAYERS; ALUMINUM; SENSOR; OCTADECYLSILOXANE;
D O I
10.1016/j.snb.2012.07.113
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The present study evaluates the performance and potential utility of apertured impedance microchips (AIMs). The electronics-based, dielectric constant detection devices feature a novel layered architecture with aluminum metal/silicon-oxide/silicon layers, where the top metal layer has apertures and the middle oxide layer has wells. This layered yet open geometry enables molecules to have access to detection of electric fields induced by a voltage applied between the top metal/bottom silicon electrode layers. Our design rationale surmised that the AIM device's large footprint area and thin nanoscale oxide layer should enable impedance detection of molecules with high sensitivity in a variety of solvents. The present study confirms this hypothesis and explores the effects that simple surface modifications have on the device's response. Specifically, the affinity between various analytes and the device's surface is evaluated when: (a) the aluminum top electrode is hydrated and rendered hydrophilic by immersing the microchip in boiling water, and (b) the silicon substrate is stripped of oxide and rendered hydrophobic (hydrogen-terminated) by hydrofluoric acid (HF) wet etching. Both types of devices were incorporated into a high performance liquid chromatography (HPLC) system already equipped with an ultra-violet-visible (UV-vis) detector. A range of analytes was injected using both normal and reverse phase modes; and the signals generated by each microchip device and UV-vis detector were recorded simultaneously and compared. The microchip devices' responses were found to vary for analytes according to the surface modification used. The second surface modification method of exposing bare silicon surface showed greater sensitivity than the first method for all the analytes. Both types of devices were remarkably sensitive to organic salts tested, i.e., their sensitivity was significantly greater than that of the UV-vis detector. To demonstrate the novel dielectric constant capability of AIM, as a case study, the HF-treated device was used to detect enantiomers of a synthesized chiral molecule separated by a chiral column using an insulating eluent, namely hexanes/isopropanol. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:852 / 861
页数:10
相关论文
共 50 条
  • [21] USING A MICROPROCESSOR IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    BERRIDGE, JC
    MICROPROCESSORS AND MICROSYSTEMS, 1983, 7 (01) : 19 - 23
  • [22] Towards using high-performance liquid chromatography at home
    Lankelma, Jan
    van Iperen, Dirck J.
    van der Sluis, Paul J.
    JOURNAL OF CHROMATOGRAPHY A, 2021, 1639
  • [23] Determination of polyvinylpyrrolidone using high-performance liquid chromatography
    Jones, SA
    Martin, GP
    Brown, MB
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2004, 35 (03) : 621 - 624
  • [24] Determination of ceftazidime and impurities using high performance liquid chromatography
    Jiang Enzhu
    Hu Changqin
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2008, 26 (01) : 75 - 79
  • [25] Bioanalysis of aminoglycosides using high-performance liquid chromatography
    Amponsah, Seth K.
    Boadu, Joseph A.
    Dwamena, Daniel K.
    Opuni, Kwabena F. M.
    ADMET AND DMPK, 2022, 10 (01): : 27 - 62
  • [26] Determination of decabromodiphenyl ethane using high performance liquid chromatography
    Yang Yang
    Chen Jianhai
    Chang Liping
    Huang Qi
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2008, 26 (05) : 646 - 648
  • [27] Evaluation of high performance liquid chromatography modular system for the diagnosis of haemoglobinopathies
    Lusina, D
    Sifi, A
    Mathieu, P
    Adam, MN
    Le Pennec, MP
    Guérout, T
    Balédent, F
    ANNALES DE BIOLOGIE CLINIQUE, 1998, 56 (06) : 734 - 739
  • [28] PURITY EVALUATION OF DIPYRIDAMOLE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    FONTANI, F
    FINARDI, GP
    TARGA, G
    BESANA, GP
    LIGORATI, M
    JOURNAL OF CHROMATOGRAPHY, 1983, 280 (01): : 181 - 187
  • [29] Surface modification of steel using liquid jet peening (Fatigue performance)
    Gnanamoorth, R.
    Grinspan, A. Sahaya
    THERMEC 2006, PTS 1-5, 2007, 539-543 : 1140 - +
  • [30] Evaluation of iGDGT carbon isotope fractionation in high performance liquid chromatography
    Keller, Katherine J.
    Phelps, Samuel R.
    Pearson, Ann
    ORGANIC GEOCHEMISTRY, 2023, 176