Apertured impedance microchips: Surface modification and evaluation using high performance liquid chromatography

被引:1
|
作者
Suganuma, Yoshinori [1 ]
Menard, Frederic [1 ]
Lautens, Mark [1 ]
Dhirani, Al-Amin [1 ]
机构
[1] Univ Toronto, Dept Chem, Toronto, ON M5S 3H6, Canada
来源
关键词
Impedance detection; Dielectric constant detection; Capacitive sensors; Surface functionalization; Microfluidics; High performance liquid chromatography (HPLC); CAPACITANCE PROBE; SILICON-OXIDE; REAL-TIME; OIL; WATER; FUNCTIONALIZATION; MONOLAYERS; ALUMINUM; SENSOR; OCTADECYLSILOXANE;
D O I
10.1016/j.snb.2012.07.113
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The present study evaluates the performance and potential utility of apertured impedance microchips (AIMs). The electronics-based, dielectric constant detection devices feature a novel layered architecture with aluminum metal/silicon-oxide/silicon layers, where the top metal layer has apertures and the middle oxide layer has wells. This layered yet open geometry enables molecules to have access to detection of electric fields induced by a voltage applied between the top metal/bottom silicon electrode layers. Our design rationale surmised that the AIM device's large footprint area and thin nanoscale oxide layer should enable impedance detection of molecules with high sensitivity in a variety of solvents. The present study confirms this hypothesis and explores the effects that simple surface modifications have on the device's response. Specifically, the affinity between various analytes and the device's surface is evaluated when: (a) the aluminum top electrode is hydrated and rendered hydrophilic by immersing the microchip in boiling water, and (b) the silicon substrate is stripped of oxide and rendered hydrophobic (hydrogen-terminated) by hydrofluoric acid (HF) wet etching. Both types of devices were incorporated into a high performance liquid chromatography (HPLC) system already equipped with an ultra-violet-visible (UV-vis) detector. A range of analytes was injected using both normal and reverse phase modes; and the signals generated by each microchip device and UV-vis detector were recorded simultaneously and compared. The microchip devices' responses were found to vary for analytes according to the surface modification used. The second surface modification method of exposing bare silicon surface showed greater sensitivity than the first method for all the analytes. Both types of devices were remarkably sensitive to organic salts tested, i.e., their sensitivity was significantly greater than that of the UV-vis detector. To demonstrate the novel dielectric constant capability of AIM, as a case study, the HF-treated device was used to detect enantiomers of a synthesized chiral molecule separated by a chiral column using an insulating eluent, namely hexanes/isopropanol. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:852 / 861
页数:10
相关论文
共 50 条
  • [1] Modification of a conventional high performance liquid chromatograph for use in high speed liquid chromatography
    Gomis, DB
    Núnez, NS
    García, EA
    Abrodo, PA
    Alvarez, MDG
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2006, 29 (13) : 1861 - 1875
  • [2] Optimization strategies using response surface methodologies in high performance liquid chromatography
    Zhang, Yi-Jun
    Gong, Wen-Jun
    Zhang, Jia-Ming
    Zhang, Yu-Ping
    Wang, Shu-Ming
    Wang, Li
    Xue, Hui-Yong
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2008, 31 (19) : 2893 - 2916
  • [3] Evaluation of zirconia support for high performance liquid chromatography
    Feng, YQ
    Zhang, QH
    Da, SL
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 27 (08) : 938 - 941
  • [4] MODIFICATION OF A CONVENTIONAL HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AUTOINJECTOR FOR USE WITH CAPILLARY LIQUID-CHROMATOGRAPHY
    SIMPSON, RC
    JOURNAL OF CHROMATOGRAPHY A, 1995, 691 (1-2) : 163 - 170
  • [5] Evaluation of purification schemes in the determination of tylosin in honey using high performance liquid chromatography
    Kochansky, J
    JOURNAL OF APICULTURAL RESEARCH, 2004, 43 (02) : 60 - 64
  • [6] SURFACE IONIZATION DETECTOR FOR HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY
    Suga, Takuya
    Takahashi, Seiji
    Fujii, Toshihiro
    ANALYTICAL LETTERS, 2014, 47 (03) : 389 - 397
  • [7] Preparation and evaluation of carbon coated alumina as a high surface area packing material for high performance liquid chromatography
    Paek, Changyub
    McCormick, Alon V.
    Carr, Peter W.
    JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (42) : 6475 - 6483
  • [8] Quality evaluation of alismatis rhizoma by high performance liquid chromatography
    Sang Myung Lee
    Jong Seong Kang
    Gwi Seo Hwang
    Young Ho Kim
    Cheal Gyu Lee
    Woon Hyung Yeo
    KiHwan Bae
    Archives of Pharmacal Research, 2004, 27 : 460 - 464
  • [9] Quality evaluation of alismatis rhizoma by high performance liquid chromatography
    Lee, SM
    Kang, JS
    Hwang, GS
    Kim, YH
    Lee, CG
    Yeo, WH
    Bae, KH
    ARCHIVES OF PHARMACAL RESEARCH, 2004, 27 (04) : 460 - 464
  • [10] Polymer Microchips Integrating Solid-Phase Extraction and High-Performance Liquid Chromatography Using Reversed-Phase Polymethacrylate Monoliths
    Liu, Jikun
    Chen, Chien-Fu
    Tsao, Chia-Wen
    Chang, Chien-Cheng
    Chu, Chin-Chou
    DeVoe, Don L.
    ANALYTICAL CHEMISTRY, 2009, 81 (07) : 2545 - 2554