Finite volume and response surface methodology based performance prediction and optimization of a hybrid earth to air tunnel heat exchanger

被引:39
作者
Kaushal, Maneesh [1 ]
Dhiman, Prashant [1 ]
Singh, Satyender [1 ]
Patel, Hariram [2 ]
机构
[1] Natl Inst Technol, Hamirpur 177005, HP, India
[2] Larsen & Toubro Ltd, Madras 600089, Tamil Nadu, India
关键词
Heater; EAHX; HEAHX; RSM; ANN; Heat-transfer; COOLING SYSTEM; TEMPERATURE; MASS;
D O I
10.1016/j.enbuild.2015.07.014
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In the present investigation, finite volume method is applied for the thermal performance prediction of a hybrid earth to air tunnel heat exchanger whereas process parameters are optimized using response surface methodology. A commercial CFD based software-ANSYS Fluent is used to simulate the heat exchanger. RNG k-epsilon turbulence model was selected to carry out a two-dimensional simulation modelling. Moreover, response surface methodology is applied to analyse the results of finite volume method and to optimize the process parameters of hybrid earth to air tunnel heat exchanger (HEAHX). The numerical results obtained from HEAHX are compared with that of individual EAHX. It is found that performance of HEAHX is about three times higher than as compared to individual EAHX. In addition, the theoretical results of present study are validated with theoretical results obtained from previous works and a good agreement is achieved. The maximum difference between the outlet and inlet air temperatures of hybrid and individual earth to air heat exchangers at the optimum value of input parameters are found to be 49.83 K and 14.4 K, respectively. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:25 / 35
页数:11
相关论文
共 30 条
[1]   Earth-to-air heat exchangers for Italian climates [J].
Ascione, Fabrizio ;
Bellia, Laura ;
Minichiello, Francesco .
RENEWABLE ENERGY, 2011, 36 (08) :2177-2188
[2]   PERFORMANCE OF EARTH AIR TUNNELS [J].
BANSAL, NK ;
SODHA, MS ;
BHARADWAJ, SS .
INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 1983, 7 (04) :333-345
[3]   'Derating Factor' new concept for evaluating thermal performance of earth air tunnel heat exchanger: A transient CFD analysis [J].
Bansal, Vikas ;
Misra, Rohit ;
Das Agarwal, Ghanshyam ;
Mathur, Jyotirmay .
APPLIED ENERGY, 2013, 102 :418-426
[4]   Performance analysis of integrated earth-air-tunnel-evaporative cooling system in hot and dry climate [J].
Bansal, Vikas ;
Mishra, Rohit ;
Das Agarwal, Ghanshyam ;
Mathur, Jyotirmay .
ENERGY AND BUILDINGS, 2012, 47 :525-532
[5]   Performance analysis of earth-pipe-air heat exchanger for summer cooling [J].
Bansal, Vikas ;
Misra, Rohit ;
Das Agrawal, Ghanshyam ;
Mathur, Jyotirmay .
ENERGY AND BUILDINGS, 2010, 42 (05) :645-648
[6]   Performance analysis of earth-pipe-air heat exchanger for winter heating [J].
Bansal, Vikas ;
Misra, Rohit ;
Das Agrawal, Ghanshyam ;
Mathur, Jyotirmay .
ENERGY AND BUILDINGS, 2009, 41 (11) :1151-1154
[7]  
Bharadwaj S.S., 1983, International Journal of Building and Environment, V16, P183, DOI DOI 10.1016/0360-1323(81)90012-3
[8]   Energy from a two-pipe, earth-to-air heat exchanger [J].
Bojic, M ;
Papadakis, G ;
Kyritsis, S .
ENERGY, 1999, 24 (06) :519-523
[9]  
Carslaw H.S., 1986, Conduction of Heat In Solids, V2nde
[10]   Subsoil heat exchangers for the air conditioning of livestock buildings [J].
Deglin, D ;
Van Caenegem, L ;
Dehon, P .
JOURNAL OF AGRICULTURAL ENGINEERING RESEARCH, 1999, 73 (02) :179-188