A portable microfluidic system for rapid measurement of the erythrocyte sedimentation rate

被引:45
|
作者
Isiksacan, Ziya [1 ]
Erel, Ozcan [2 ]
Elbuken, Caglar [1 ]
机构
[1] Bilkent Univ, Inst Mat Sci & Nanotechnol, Natl Nanotechnol Res Ctr UNAM, TR-06800 Ankara, Turkey
[2] Yildirim Beyazit Univ, Fac Med, Ankara, Turkey
关键词
RED-BLOOD-CELL; THRESHOLD SHEAR-STRESS; TEST; ANALYZER; ROULEAUX FORMATION; AGGREGATION; FLOW;
D O I
10.1039/c6lc01036a
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The erythrocyte sedimentation rate (ESR) is a frequently used 30 min or 60 min clinical test for screening of several inflammatory conditions, infections, trauma, and malignant diseases, as well as non-inflammatory conditions including prostate cancer and stroke. Erythrocyte aggregation (EA) is a physiological process where erythrocytes form face-to-face linear structures, called rouleaux, at stasis or low shear rates. In this work, we proposed a method for ESR measurement from EA. We developed a microfluidic opto-electro-mechanical system, using which we experimentally showed a significant correlation (R-2 = 0.86) between ESR and EA. The microfluidic system was shown to measure ESR from EA using fingerprick blood in 2 min. 40 mu l of whole blood is filled in a disposable polycarbonate cartridge which is illuminated with a near infrared emitting diode. Erythrocytes were disaggregated under the effect of a mechanical shear force using a solenoid pinch valve. Following complete disaggregation, transmitted light through the cartridge was measured using a photodetector for 1.5 min. The intensity level is at its lowest at complete disaggregation and highest at complete aggregation. We calculated ESR from the transmitted signal profile. We also developed another microfluidic cartridge specifically for monitoring the EA process in real-time during ESR measurement. The presented system is suitable for ultrafast, low-cost, and low-sample volume measurement of ESR at the point-of-care.
引用
收藏
页码:4682 / 4690
页数:9
相关论文
共 39 条
  • [21] Increased Erythrocyte Sedimentation Rate in Dogs: Frequency in Routine Clinical Practice and Association with Hematological Changes
    Paltrinieri, Saverio
    Ferrari, Roberta
    Scavone, Donatella
    Pieroni, Carolina
    Diamanti, Daniela
    Tagliasacchi, Filippo
    ANIMALS, 2024, 14 (10):
  • [22] Revisiting diagnostics: erythrocyte sedimentation rate and C-reactive protein: it is time to stop the zombie tests
    Spellberg, Brad
    Nielsen, Travis B.
    Phillips, Matthew C.
    Ghanem, Bassam
    Boyles, Tom
    Jegorovic, Boris
    Footer, Brent
    Mah, Jordan K.
    Lieu, Anthony
    Scott, Jake
    Wald-Dickler, Noah
    Lee, Todd C.
    Mcdonald, Emily G.
    CLINICAL MICROBIOLOGY AND INFECTION, 2025, 31 (01) : 1 - 4
  • [23] Evaluation of the TEST 1 erythrocyte sedimentation rate system and intra- and inter-laboratory quality control using new latex control materials
    Cha, Choong-Hwan
    Cha, Young Joo
    Park, Chan-Jeoung
    Kim, Hyun Kyung
    Cha, Eun-Jong
    Kim, Duck Hee
    Honghoon
    Jung, Jae-Seol
    Kim, Mi-Jung
    Jang, Seongsoo
    Chi, Hyun-Sook
    Lee, Dong Soon
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2010, 48 (07) : 1043 - 1048
  • [24] Evaluation of rapid transepithelial electrical resistance (TEER) measurement as a metric of kidney toxicity in a high-throughput microfluidic culture system
    Shaughnessey, Erin M.
    Kann, Samuel H.
    Azizgolshani, Hesham
    Black, Lauren D., III
    Charest, Joseph L.
    Vedula, Else M.
    SCIENTIFIC REPORTS, 2022, 12 (01) : 13182
  • [25] Clinical application of a new method for determination of the erythrocyte sedimentation rate using the BC-720 automated hematology analyzer
    Shen, Yimin
    Liu, Dongmei
    Wang, Yong
    Cao, Jun
    Zhang, Shuaishuai
    Wen, Hui
    Dong, Qiuqiu
    Zheng, Dong
    Qiu, Jun
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2023, 45 (04) : 449 - 459
  • [26] Image Processing-based Measurement of Volume for Droplets in the Microfluidic System
    Wei, Wei
    Guo, Shuxiang
    Wu, Fang
    Ji, Yuehui
    Wang, Yunliang
    2013 ICME INTERNATIONAL CONFERENCE ON COMPLEX MEDICAL ENGINEERING (CME), 2013, : 518 - 522
  • [27] Droplet-based microfluidic sensing system for rapid fish freshness determination
    Itoh, Daisuke
    Sassa, Fumihiro
    Nishi, Taiji
    Kani, Yoko
    Murata, Masakazu
    Suzuki, Hiroaki
    SENSORS AND ACTUATORS B-CHEMICAL, 2012, 171 : 619 - 626
  • [28] Rapid integrated microfluidic paper-based system for sulfur dioxide detection
    Liu, Chan-Chiung
    Wang, Yao-Nan
    Fu, Lung-Ming
    Yang, Dong-Yu
    CHEMICAL ENGINEERING JOURNAL, 2017, 316 : 790 - 796
  • [29] Novel characteristics of soluble fibrin: hypercoagulability and acceleration of blood sedimentation rate mediated by its generation of erythrocyte-linked fibers
    Galanakis, Dennis K.
    Protopopova, Anna
    Li, Kao
    Yu, Yingjie
    Ahmed, Tahmeena
    Sensel, Lisa
    Heslin, Ryan
    Gouda, Mohamed
    Koo, Jaseung
    Weisel, John
    Manco-Johnson, Marilyn
    Rafailovich, Miriam
    CELL AND TISSUE RESEARCH, 2022, 387 (03) : 479 - 491
  • [30] Quantitative Measurement of the Erythrocyte Sedimentation Based on Electrical Impedance Spectroscopy With Modified HANAI Theory and the Multi-Frequency Parameter Xc
    Li, Jianping
    Brahim, El Maalouma Sidi
    Wen, Jianming
    Wan, Nen
    Hu, Yili
    He, Lidong
    Takei, Masahiro
    IEEE SENSORS JOURNAL, 2021, 21 (23) : 27084 - 27092