EFFECT OF THE THICKNESS OF PAN/Au MODIFIED ELECTRODE ON BIOSENSOR SENSITIVITY

被引:1
|
作者
Dong, Bo [1 ]
Lu, Xiaofeng [1 ]
Li, Zhenyu [1 ]
Zhang, Hongnan [1 ]
Wang, Zongxin [1 ]
Wang, Ce [1 ]
Liu, Zongwen [2 ]
机构
[1] Jilin Univ, Alan G MacDiarmid Inst, Changchun 130012, Peoples R China
[2] Univ Sydney, Sch Chem & Biomol Engn, Sydney, NSW 2006, Australia
关键词
Membrane thickness; polyacrylonitrile/gold nanofibers; electrocatalytic; hydrogen peroxide reduction; GOLD NANOPARTICLES;
D O I
10.1142/S179360471250035X
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A simple electrospinning method was used to control the thickness of polyacrylonitrile ( PAN)/Au modified electrode. The influence of membrane thickness to modified electrode sensitivity was discussed. In our experiment, a 20-min electrospinning time and a mass ratio of 3:1 PAN/HAuCl4 are the optimum parameters to generate the high performance PAN/Au membrane modified electrode for detecting H2O2 which has a sensitivity of 145.63 mA M-1 cm(-2)) and a wide linear range of 20 mu M-20 mM.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] Glucose Biosensor at Ethylenediamine Modified Carbon Electrode
    Jarrar, H.
    Rolland, M.
    Downard, A. J.
    Cretin, M.
    SENSOR LETTERS, 2011, 9 (06) : 2368 - 2370
  • [22] Amperometric glucose biosensor with high sensitivity based on self-assembled Prussian Blue modified electrode
    Liu, Yu
    Chu, Zhenyu
    Zhang, Yannan
    Jin, Wanqin
    ELECTROCHIMICA ACTA, 2009, 54 (28) : 7490 - 7494
  • [23] Amperometric cholesterol biosensor based on cholesterol oxidase and Pt-Au/ MWNTs modified glassy carbon electrode
    Haritha, V. S.
    Kumar, S. R. Sarath
    Rakhi, R. B.
    MATERIALS TODAY-PROCEEDINGS, 2022, 50 : 34 - 39
  • [24] Detremination of kinetic effect of Metoprolol and Ranitidine on HRP-modified GC electrode biosensor
    Besic, Zerina
    Herenda, Safija
    Stankovic, Trivo
    Ostojic, Jelena
    PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON MEDICAL AND BIOLOGICAL ENGINEERING 2017 (CMBEBIH 2017), 2017, 62 : 410 - 414
  • [25] DNA Electrochemical Biosensor Based on Au Nanoparticles Self-Assembled Au Electrode
    Liu, Yan
    Dai, Zhao
    Xu, Shichao
    Zhang, Jimei
    Zheng, Guo
    Zhang, Qingyin
    Chen, Guangping
    SOFT MAGNETIC MATERIALS, 2011, 298 : 78 - +
  • [26] Enhancement effect of hydrophilic Au and hydrophobic SiO2 nanoparticles on glucose biosensor sensitivity
    Tang, FQ
    Wei, Z
    Chen, D
    Meng, XW
    Gou, L
    Ran, JG
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2000, 21 (01): : 91 - 94
  • [27] Enhancement Effect of Hydrophilic Au and Hydrophobic SiO2 Nanoparticles on Glucose Biosensor Sensitivity
    Tang, Fang-Qiong
    Wei, Zheng
    Chen, Dong
    Meng, Xian-Wei
    Gou, Li
    Ran, Jun-Guo
    Kao Teng Hsueh Hsiao Hua Heush Hsueh Pao/ Chemical Journal of Chinese Universities, 2000, 21 (01):
  • [28] An Formaldehyde Biosensor Based on Carbon Nanotubes Modified Electrode
    Zhang Ren-Yan
    Zhang Xue-Ao
    Jia Hong-Hui
    Li Xin-Hua
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2012, 40 (06) : 909 - 914
  • [29] Effect of Metal Film, Thickness and Various Solvents on the SPR Biosensor Sensitivity for illegal Compound Detection
    Suherman
    Hossain, Md Motahar
    Morita, Kinichi
    Kawaguchi, Toshikazu
    ORIENTAL JOURNAL OF CHEMISTRY, 2018, 34 (03) : 1355 - 1361
  • [30] An amperometric biosensor using Prussian blue modified electrode
    Yi, In-Je
    Kim, Ju-Ho
    Kang, C. J.
    Park, Jaehyun
    Kim, Yong-Sang
    ECO-MATERIALS PROCESSING & DESIGN VII, 2006, 510-511 : 746 - 749