Esophageal Doppler (ODM II) improves intraoperative hemodynamic monitoring during laparoscopic surgery

被引:16
作者
Koliopanos, A
Zografos, G
Skiathitis, S
Stithos, D
Voukena, V
Karampinis, A
Papastratis, G
机构
[1] Gen Hosp Athens, Dept Gen Surg, Athens, Greece
[2] Gen Hosp Athens, Dept Anesthesia, Athens, Greece
[3] Gen Hosp Athens, Intens Care Unit, Athens, Greece
关键词
ODM II; monitoring; hemodynamics; cardiac output; laparoscopy;
D O I
10.1097/01.sle.0000191631.66505.4a
中图分类号
R61 [外科手术学];
学科分类号
摘要
Minimally invasive laparoscopic surgery has been expanded to the elderly and high-risk surgical patients with underlying cardiac and pulmonary disease. However, possible cardiovascular changes during CO2 pneumoperitoneum necessitate close intraoperative monitoring. In this prospective study, 55 patients (mean age 62.52 years, range 26-82) undergoing laparoscopic surgery were included. Patients were categorized into 3 groups of low (group A: 12 patients, mean age 55.5 years), moderate (group B: 22 patients, mean age 59.5 years), and high (group C: 21 patients, mean age 69.71 years) surgical risk according to ASA physical status classification. Similar anesthetic agents and anesthetic techniques were used in the above cases. An esophageal Doppler (ODM II, Abbott Laboratories) was used to measure aortic blood flow velocity and thereby estimating stroke volume (SVe) and cardiac output (COe) throughout anesthesia, in addition to traditional monitoring. After abdominal insufflation (peak intra-abdominal pressure: 13-15 mm Hg) COe values decreased from the initial value after induction of anesthesia by 22%, 20%, and 18% for groups A, B, and C, respectively (P < 0.05). The above values further deteriorated (25%, 28%, and 30% for groups A, B, and C, respectively) in the anti-Trendelenburg positioning of the patient. The peak aortic blood flow velocity (PV) followed the changes, thus indicating that heart muscle contractility is affected during the procedure. Stabilization of the above values was achieved after 20 minutes Of CO2 pneumoperitoneum and improvement was noted only after deflation of the abdomen. Heart rate and blood pressure essentially remained unchanged throughout the procedure, although the final values were increased compared with initial. Insufflation of the abdomen with CO2 produces measurable effects on the cardiovascular system that require reappraisal of hemodynamic monitoring during anesthesia. ODM II offers a reliable, relatively noninvasive, cost-effective tool for intraoperative monitoring of the hemodynamic changes with a potential for future application for improvement of intraoperative hemodynamic status of patients.
引用
收藏
页码:332 / 338
页数:7
相关论文
共 50 条
  • [1] Intraoperative Esophageal Doppler Hemodynamic Monitoring in Free Perforator Flap Surgery
    Figus, Andrea
    Wade, Ryckie G.
    Oakey, Stephen
    Ramakrishnan, Venkat V.
    ANNALS OF PLASTIC SURGERY, 2013, 70 (03) : 301 - 307
  • [2] Validation of esophageal Doppler for noninvasive hemodynamic monitoring under pneumoperitoneum
    Okrainec, A.
    Bergman, S.
    Demyttenaere, S.
    Feldman, L. S.
    Nutting, A.
    Carli, F.
    Fried, G. M.
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2007, 21 (08): : 1349 - 1353
  • [3] Validation of esophageal Doppler for noninvasive hemodynamic monitoring under pneumoperitoneum
    A. Okrainec
    S. Bergman
    S. Demyttenaere
    L. S. Feldman
    A. Nutting
    F. Carli
    G. M. Fried
    Surgical Endoscopy, 2007, 21 : 1349 - 1353
  • [4] Hemodynamic monitoring and correlation between electrical cardiometry and esophageal Doppler in patients undergoing major abdominal surgery
    Abdalla, Shady Rady
    Abdelazeem, Ahmed Salah
    Kaddah, Tarek Abdelhalium
    Elhadedy, Abla Salah
    Khafagy, Hanan Farouk
    Mohamed, Ahmed Abdalla
    Essam, Ahmed Mohamed
    EGYPTIAN JOURNAL OF ANAESTHESIA, 2023, 39 (01): : 418 - 425
  • [5] Intraoperative microvascular Doppler monitoring in intracranial aneurysm surgery
    Hui Pin-jing
    Yan Yan-hong
    Zhang Shi-ming
    Wang Zhong
    Yu Zheng-quan
    Zhou You-xin
    Li Xiang-dong
    Cui Gang
    Zhou Dai
    Hui Guo-zhen
    Lan Qing
    CHINESE MEDICAL JOURNAL, 2013, 126 (13) : 2424 - 2429
  • [6] Comparison of Proaqt/Pulsioflex® and oesophageal Doppler for intraoperative haemodynamic monitoring during intermediate-risk abdominal surgery
    Weil, Gregoire
    Motamed, Cyrus
    Eghiaian, Alexandre
    Monnet, Xavier
    Suria, Stephanie
    ANAESTHESIA CRITICAL CARE & PAIN MEDICINE, 2019, 38 (02) : 153 - 159
  • [7] Intraoperative clinical application of hemodynamic monitoring in noncardiac surgery patients
    Renner, J.
    Saugel, B.
    Reuter, D. A.
    Kouz, K.
    Flick, M.
    Zitzmann, A.
    Habicher, M.
    Annecke, T.
    ANAESTHESIOLOGIE, 2024, 73 (08): : 535 - 542
  • [8] Intraoperative management and hemodynamic monitoring for major abdominal surgery : a narrative review
    Russo, A.
    Roman, B.
    ACTA ANAESTHESIOLOGICA BELGICA, 2021, 72 (02) : 63 - 71
  • [9] HEMODYNAMIC-CHANGES DURING PROLONGED LAPAROSCOPIC SURGERY
    WINDBERGER, U
    SIEGL, H
    WOISETSCHLAGER, R
    SCHRENK, P
    PODESSER, B
    LOSERT, U
    EUROPEAN SURGICAL RESEARCH, 1994, 26 (01) : 1 - 9
  • [10] Hemodynamic Monitoring During Heated Intraoperative Intraperitoneal Chemotherapy Using the FloTrac/Vigileo System
    Mavroudis, Christos
    Alevizos, Leonidas
    Stamou, Konstantinos M.
    Vogiatzaki, Theodosia
    Eleftheriadis, Savvas
    Korakianitis, Odysseas
    Tentes, Antonios A.
    Iatrou, Christos
    INTERNATIONAL SURGERY, 2015, 100 (06) : 1033 - 1039