Assessment of the performance of composite steel shear walls with T-shaped stiffeners

被引:0
作者
Zanintala, Hadi [1 ]
Maleki, Ahmad [1 ]
Yaghin, Mohammad Ali Lotfollahi [2 ]
机构
[1] Islamic Azad Univ, Dept Civil Engn, Maragheh Branch, Maragheh, Iran
[2] Univ Tabriz, Fac Civil Engn, Tabriz, Iran
关键词
composite steel plate shear wall (CSPSW); FE method; performance; T-shaped stiffener; ultimate capacity; BUCKLING-RESTRAINED FUSE; BEAM-COLUMN JOINTS; CYCLIC BEHAVIOR; FINITE-ELEMENT; FRAMES; SIMULATION; SYSTEM; MODEL;
D O I
10.12989/eas.2022.23.3.297
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Composite steel plate shear wall (CSPSW) is a relatively novel structural system proposed to improve the performance of steel plate shear walls by adding one or two layers of concrete walls to the infill plate. In addition, the buckling of the infill steel plate has a significant negative effect on the shear strength and energy dissipation capacity of the overall systems. Accordingly, in this study, using the finite element (FE) method, the performance and behavior of composite steel shear walls using T-shaped stiffeners to prevent buckling of the infill steel plate and increase the capacity of CSPSW systems have been investigated. In this paper, after modeling composite steel plate shear walls with and without steel plates with finite element methods and calibration the models with experimental results, effects of parameters such as several stiffeners, vertical, horizontal, diagonal, and a combination of T-shaped stiffeners located in the composite wall have been investigated on the ultimate capacity, web-plate buckling, von-Mises stress, and failure modes. The results showed that the arrangement of stiffeners has no significant effect on the capacity and performance of the CSPSW so that the use of vertical or horizontal stiffeners did not have a significant effect on the capacity and performance of the CSPSW. On the other hand, the use of diagonal hardeners has potentially affected the performance of CSPSWs, increasing the capacity of steel shear walls by up to 25%.
引用
收藏
页码:297 / 313
页数:17
相关论文
共 57 条
[1]   Simulation of cyclic response of precast concrete beam-column joints [J].
Adibi, Mahdi ;
Talebkhah, Roozbeh ;
Yahyaabadi, Aliakbar .
COMPUTERS AND CONCRETE, 2019, 24 (03) :223-236
[2]  
AISC, 2010, ANSIAISC 341 10 SEIS
[3]  
American Concrete Institute, 2014, FARM HILLS MI
[4]  
[Anonymous], 2014, ABAQUS-6.14
[5]   Experimental investigation of composite shear walls under shear loadings [J].
Arabzadeh, A. ;
Soltani, M. ;
Ayazi, A. .
THIN-WALLED STRUCTURES, 2011, 49 (07) :842-854
[6]  
Astaneh-Asl A., 2002, Seismic Behavior and Design of Composite Steel Plate Shear Walls
[7]   Assessment of damage index and seismic performance of steel plate shear wall (SPSW) system [J].
Azandariani, Ali Gorji ;
Gholhaki, Majid ;
Azandariani, Mojtaba Gorji .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2022, 191
[8]   Assessment of cyclic behavior and performance of hybrid linked-column steel plate shear wall system [J].
Azandariani, Mojtaba Gorji ;
Gholhaki, Majid ;
Kafi, Mohammad Ali ;
Azandariani, Ali Gorji .
JOURNAL OF BUILDING ENGINEERING, 2022, 58
[9]   Seismic fragility investigation of hybrid structures BRBF with eccentric-configuration and self-centering frame [J].
Azandariani, Mojtaba Gorji ;
Gholami, Mohammad .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2022, 196
[10]   Numerical and analytical study of ultimate capacity of steel plate shear walls with partial plate-column connection (SPSW-PC) [J].
Azandariani, Mojtaba Gorji ;
Rousta, Ali Mohammad ;
Mohammadi, Masoud ;
Rashidi, Maria ;
Abdolmaleki, Hamid .
STRUCTURES, 2021, 33 :3066-3080