Monte Carlo study of a highly efficient gas ionization detector for megavoltage imaging and image-guided radiotherapy

被引:45
作者
Keller, H [1 ]
Glass, M
Hinderer, R
Ruchala, K
Jeraj, R
Olivera, G
Mackie, TR
机构
[1] Univ Wisconsin, Dept Med Phys, Madison, WI 53706 USA
[2] Tomotherapy Inc, Madison, WI 53706 USA
关键词
megavoltage photon radiation detector; megavoltage CT; quantum efficiency; resolution;
D O I
10.1118/1.1445414
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The imaging characteristics of an arc-shaped xenon gas ionization chamber for the purpose of megavoltage CT imaging were investigated. The detector consists of several hundred 320 mum thick gas cavities separated by thin tungsten plates of the same thickness. Dose response, efficiency and resolution parameters were calculated using Monte Carlo simulations. The calculations were compared to measurements taken in a 4 MV photon beam, assuming that the measured signal in the chambers corresponds to the therein absorbed dose. The measured response profiles for narrow and broad incident photon beams could be well reproduced with the Monte Carlo calculations. They show, that the quantum efficiency is 29.2% and the detective quantum efficiency at zero frequency DQE(0) is 20.4% for the detector arc placed in focus with the photon source. For a detector placed out of focus, these numbers even increase. The efficiency of this kind of radiation detector for megavoltage radiation therefore surpasses the reported efficiency of existing detector technologies. The resolution of the detector is quantified with calculated and measured line spread functions. The corresponding modulation transfer functions were determined for different thicknesses of the tungsten plates. They show that the resolution is only slightly dependent on the plate thickness but is predominantly determined by the cell size of the detector. The optimal plate thickness is determined by a tradeoff between quantum efficiency, total signal generation and resolution. Thicker plates are more efficient but the total signal and the resolution decrease with plate thickness. In conclusion, a gas ionization chamber of the described type is a highly efficient megavoltage radiation detector, allowing to obtain CT images with very little dose for a sufficient image quality for anatomy verification. This kind of detector might serve as a model for a future generation of highly efficient radiation detectors. (C) 2002 American Association of Physicists in Medicine.
引用
收藏
页码:165 / 175
页数:11
相关论文
共 24 条
[1]  
BALOG J, 1998, THESIS U WISCONSIN M
[2]  
Barrett H. H., 1981, RADIOLOGICAL IMAGING
[3]   A REVIEW OF ELECTRONIC PORTAL IMAGING DEVICES (EPIDS) [J].
BOYER, AL ;
ANTONUK, L ;
FENSTER, A ;
VANHERK, M ;
MEERTENS, H ;
MUNRO, P ;
REINSTEIN, LE ;
WONG, J .
MEDICAL PHYSICS, 1992, 19 (01) :1-16
[4]   A SPATIAL-FREQUENCY DEPENDENT QUANTUM ACCOUNTING DIAGRAM AND DETECTIVE QUANTUM EFFICIENCY MODEL OF SIGNAL AND NOISE-PROPAGATION IN CASCADED IMAGING-SYSTEMS [J].
CUNNINGHAM, IA ;
WESTMORE, MS ;
FENSTER, A .
MEDICAL PHYSICS, 1994, 21 (03) :417-427
[5]  
Groh BA, 2000, USE OF COMPUTERS IN RADIATION THERAPY, P561
[6]   Feasibility of megavoltage portal CT using an electronic portal imaging device (EPID) and a multi-level scheme algebraic reconstruction technique (MLS-ART) [J].
Guan, HQ ;
Zhu, YP .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (10) :2925-2937
[7]   Tomotherapeutic portal imaging for radiation treatment verification [J].
Hesse, BM ;
Spies, L ;
Groh, BA .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (12) :3607-3616
[8]   MONTE-CARLO STUDIES OF X-RAY-ENERGY ABSORPTION AND QUANTUM-NOISE IN MEGAVOLTAGE TRANSMISSION RADIOGRAPHY [J].
JAFFRAY, DA ;
BATTISTA, JJ ;
FENSTER, A ;
MUNRO, P .
MEDICAL PHYSICS, 1995, 22 (07) :1077-1088
[9]   Managing geometric uncertainty in conformal intensity-modulated radiation therapy [J].
Jaffray, DA ;
Yan, D ;
Wong, JW .
SEMINARS IN RADIATION ONCOLOGY, 1999, 9 (01) :4-19
[10]   A radiographic and tomographic imaging system integrated into a medical linear accelerator for localization of bone and soft-tissue targets [J].
Jaffray, DA ;
Drake, DG ;
Moreau, M ;
Martinez, AA ;
Wong, JW .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 45 (03) :773-789