Comparative study of reproducibility and accuracy in measuring mesiodistal tooth sizes using three different methods: 2D digital, 3D CBCT, and 3D CBCT segmented

被引:6
|
作者
Hernandez, Yanira [1 ]
Tarazona, Beatriz [1 ]
Zamora, Natalia [1 ]
Cibrian, Rosa [2 ]
Luis Gandia, Jose [1 ]
Paredes, Vanessa [1 ]
机构
[1] Univ Valencia, Fac Med & Dent, Dept Orthodont, Valencia 46010, Spain
[2] Univ Valencia, Fac Med & Dent, Dept Physiol, Valencia 46010, Spain
关键词
CBCT; Tooth size; 3D models; BEAM COMPUTED-TOMOGRAPHY; RELIABILITY; IMAGES; MODELS;
D O I
10.1007/s11282-015-0204-x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
To develop a 3D cone-beam computed tomography (CBCT) method (CBCT method) for determining tooth sizes and arch dimensions and to compare the accuracy and reproducibility of that method with those of a previously described 3D segmented CBCT method (CBCT seg. method) and a 2D digital method. Plaster study models and CBCT images were available for 34 patients. For the first method, the plaster study casts were digitalized and measured using the 2D digital method. For the second method, CBCT seg. method, the CBCT images were sent in DICOM format to InVivoDental(A (R)) Company for segmentation and conversion into three-dimensional images of the models. For the third method, CBCT method, axial cuts were performed on the CBCT images, and tooth sizes and arch dimensions were measured using Anatomage(A (R)) software. Significant differences were found between the tooth size measurements obtained with the 3D CBCT method and the 2D digital method, but not for the intercanine width, intermolar width, and arch length. There were no significant differences between the measurements obtained with the CBCT seg. method and the 2D digital method. A 3D CBCT method has been developed. It presented good accuracy for the intercanine width, intermolar width, and arch length, but not for the mesiodistal tooth sizes. Model segmentation will be necessary for measurements of tooth size.
引用
收藏
页码:165 / 172
页数:8
相关论文
共 50 条
  • [21] Reproducibility of 2D and 3D Ramus Height Measurements in Facial Asymmetry
    van Bakelen, Nicolaas B.
    van der Graaf, Jasper W.
    Kraeima, Joep
    Spijkervet, Frederik K. L.
    JOURNAL OF PERSONALIZED MEDICINE, 2022, 12 (07):
  • [22] Semi-automatic 3D reconstruction of middle and inner ear structures using CBCT
    Beguet, Florian
    Cresson, Thierry
    Schmittbuhl, Mathieu
    Doucet, Cedric
    Camirand, David
    Harris, Philippe
    Mari, Jean-Luc
    de Guise, Jacques
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING-IMAGING AND VISUALIZATION, 2023, 11 (05): : 2006 - 2019
  • [23] Reproducibility of human landmark identification in morphological mandible prototypes: major parameters for a 3D CBCT approach
    Fontes, Rebeca Menezes Vaz Queiroz
    Nunes, Tiago Alves de Carvalho
    Machado, Ricardo Filipe dos Santos
    Ribeiro, Patricia Miranda Leite
    Marques, Jeidson Antonio Morais
    Corte-Real, Ana
    FORENSIC SCIENCES RESEARCH, 2023, 8 (03) : 211 - 218
  • [24] Comparative observer effects in 2D and 3D localization tasks
    Abbey, Craig K.
    Lago, Miguel A.
    Eckstein, Miguel P.
    JOURNAL OF MEDICAL IMAGING, 2021, 8 (04)
  • [25] 3D FOURIER DOMAIN ADAPTATION FOR IMPROVING CBCT TOOTH SEGMENTATION UNDER SCANNER PARAMETER SHIFT
    Sahu, Pranjal
    Fishbaugh, James
    Vicory, Jared
    Khan, Asma
    Paniagua, Beatriz
    2023 IEEE 20TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING, ISBI, 2023,
  • [26] Assessment of sexual dimorphism using 3D CBCT image data among Indians
    Hemanthakumar, Sowmya
    Gopal, K. Saraswathi
    Kumar, P. Mahesh
    BIOINFORMATION, 2022, 18 (03) : 231 - +
  • [27] Polylactic Acid 3D Printed Drill Guide for Dental Implants Using CBCT
    David, Ovidiu Tiberiu
    Szuhanek, Camelia
    Tuce, Robert Angelo
    David, Andra Patricia
    Leretter, Marius
    REVISTA DE CHIMIE, 2017, 68 (02): : 341 - 342
  • [28] 3D CBCT human adult odontometrics: Comparative assessment in Saudi, Jordan and Egypt population
    Alam, Mohammad Khursheed
    Alzarea, Bader K.
    Ganji, Kiran Kumar
    Kundi, Ibadullah
    Patil, Santosh
    SAUDI DENTAL JOURNAL, 2019, 31 (03) : 336 - 342
  • [29] Novel 3D segmentation for reliable volumetric assessment of the nasal airway: a CBCT study
    Mupparapu, Mel
    Shi, Katherine J.
    Lo, Angela D.
    Setzer, Frank C.
    QUINTESSENCE INTERNATIONAL, 2021, 52 (02): : 154 - 164
  • [30] Reproducibility and Accuracy of Two Facial Scanners: A 3D In Vivo Study
    Pellitteri, Federica
    Calza, Marta
    Baldi, Giacomo
    De Maio, Matteo
    Lombardo, Luca
    APPLIED SCIENCES-BASEL, 2025, 15 (03):