摘要
To develop a 3D cone-beam computed tomography (CBCT) method (CBCT method) for determining tooth sizes and arch dimensions and to compare the accuracy and reproducibility of that method with those of a previously described 3D segmented CBCT method (CBCT seg. method) and a 2D digital method. Plaster study models and CBCT images were available for 34 patients. For the first method, the plaster study casts were digitalized and measured using the 2D digital method. For the second method, CBCT seg. method, the CBCT images were sent in DICOM format to InVivoDental(A (R)) Company for segmentation and conversion into three-dimensional images of the models. For the third method, CBCT method, axial cuts were performed on the CBCT images, and tooth sizes and arch dimensions were measured using Anatomage(A (R)) software. Significant differences were found between the tooth size measurements obtained with the 3D CBCT method and the 2D digital method, but not for the intercanine width, intermolar width, and arch length. There were no significant differences between the measurements obtained with the CBCT seg. method and the 2D digital method. A 3D CBCT method has been developed. It presented good accuracy for the intercanine width, intermolar width, and arch length, but not for the mesiodistal tooth sizes. Model segmentation will be necessary for measurements of tooth size.
引用
收藏
页码:165 / 172
页数:8
相关论文
共 50 条
  • [1] Comparative study of reproducibility and accuracy in measuring mesiodistal tooth sizes using three different methods: 2D digital, 3D CBCT, and 3D CBCT segmented
    Yanira Hernandez
    Beatriz Tarazona
    Natalia Zamora
    Rosa Cibrian
    Jose Luis Gandia
    Vanessa Paredes
    Oral Radiology, 2015, 31 : 165 - 172
  • [2] Comparison of linear and angular measurements in CBCT scans using 2D and 3D rendering software
    Aksoy, Secil
    Kelahmet, Umay
    Hincal, Evren
    Oz, Ulas
    Orhan, Kaan
    BIOTECHNOLOGY & BIOTECHNOLOGICAL EQUIPMENT, 2016, 30 (04) : 777 - 784
  • [3] 3D accuracy of deciduous tooth model reconstructed from CBCT scan
    Li, Hongbo
    Liu, Lin
    Gao, Yuxuan
    Shi, Xiaowei
    MEASUREMENT TECHNOLOGY AND ITS APPLICATION, PTS 1 AND 2, 2013, 239-240 : 798 - +
  • [4] A comparison between 2D and 3D cephalometry on CBCT scans of human skulls
    van Vlijmen, O. J. C.
    Maal, T.
    Berge, S. J.
    Bronkhorst, E. M.
    Katsaros, C.
    Kuijpers-Jagtman, A. M.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2010, 39 (02) : 156 - 160
  • [5] Evaluation of accuracy and repeatability using CBCT and a dental scanner by means of 3D software
    Kim, S-R.
    Kim, C-M.
    Jeong, I-D.
    Kim, W-C.
    Kim, H-Y
    Kim, J-H.
    INTERNATIONAL JOURNAL OF COMPUTERIZED DENTISTRY, 2017, 20 (01) : 65 - 73
  • [6] The impact of CBCT-head tilting on 3D condylar segmentation reproducibility
    El Bachaoui, Samy
    Verhelst, Pieter-Jan
    Vasconcelos, Karla de Faria
    Shaheen, Eman
    Coucke, Wim
    Swennen, Gwen
    Jacobs, Reinhilde
    Politis, Constantinus
    DENTOMAXILLOFACIAL RADIOLOGY, 2023, 52 (06)
  • [7] A positioning QA procedure for 2D/2D (kV/MV) and 3D/3D (CT/CBCT) image matching for radiotherapy patient setup
    Guan, Huaiqun
    Hammoud, Rabih
    Yin, Fang-Fang
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2009, 10 (04): : 273 - 280
  • [8] The Suitability of Trabecular Patterns in the Assessment of Dental Implant Osseointegration Process through 2D Digital and 3D CBCT Radiographs
    Putri, Annisa
    Pramanik, Farina
    Azhari, Azhari
    EUROPEAN JOURNAL OF DENTISTRY, 2023, : 571 - 578
  • [9] Accuracy and reliability of craniometric measurements on lateral cephalometry and 3D measurements on CBCT scans
    Gribel, Bruno Frazao
    Gribel, Marcos Nadler
    Frazao, Diogo Campos
    McNamara, James A., Jr.
    Manzi, Flavio Ricardo
    ANGLE ORTHODONTIST, 2011, 81 (01) : 26 - 35
  • [10] Software-supported periodontal diagnostics with 3D CBCT compared with conventional 2D panoramic imaging and clinical diagnostics: a prospective study
    Fleiner, Jonathan C.
    Woelber, Johan P.
    Kuerschner, Anja C.
    Lux, Hans-Christian
    Schulze, Dirk
    Hannig, Christian
    INTERNATIONAL JOURNAL OF COMPUTERIZED DENTISTRY, 2024, 27 (02) : 151 - 159