Determining the maximum operating temperature of permanent magnets via in-situ measurement of the magnetic flux

被引:4
|
作者
Gao, Weibo [1 ]
Kang, Xuyang [2 ]
Zhang, Junliang [2 ]
Chi, Zhenhua [3 ]
机构
[1] Ningbo Inst Measurement & Testing, Ningbo Inspect & Testing Ctr New Mat, Ningbo 315048, Peoples R China
[2] Ningbo Univ, Fac Elect Engn & Comp Sci, Ningbo 315211, Peoples R China
[3] Ningbo Univ, Sch Phys Sci & Technol, Inst High Pressure Phys, Ningbo 315211, Peoples R China
基金
中国国家自然科学基金;
关键词
Temperature stability; Maximum operating temperature (T-o(m)); B(H) curve; Irreversible flux loss; In-situ measurement; Magnetic flux; STABILITY;
D O I
10.1016/j.jmmm.2022.169744
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The temperature stability of a magnet is crucial for applications. Traditionally, the designers determine the maximum operating temperature (T-o(m)) of a permanent magnet by either the linearity of the B(H) curve or the irreversible flux loss. However, the reliability and efficiency of the traditional methods are challenging. Here, a new method of "in-situ measurement of the magnetic flux at elevated temperature" is introduced. By studying the temperature-dependence of magnetic flux for the Nd-Fe-B magnet, we find that the magnetic flux declines linearly as the temperature increases. Upon approaching a specific temperature, there occurs a rapid and nonlinear decline of magnetic flux.This temperature can be defined as T-o(m). Furthermore, the magnetic flux dependence on time at elevated temperature is also investigated, wherein the logarithmic relaxation is observed. The decay rate of magnetic flux could be related to the exposure temperature. If the decay rate of maximum magnetic flux loss is acceptable below a given temperature, we can also define the temperature as T-o(m).
引用
收藏
页数:5
相关论文
共 33 条
  • [31] Influence of Fe content on magnetic properties of high temperature rare earth permanent magnets Sm(CobalFexCu0.1Zr0.03)7.5(x=0.09∼0.21)
    Xu Guangliang
    Peng Long
    Zhang Ming
    Wang Jingdong
    Fu Yuqun
    Liu Li
    RARE METAL MATERIALS AND ENGINEERING, 2008, 37 (03) : 396 - 399
  • [32] In-Situ Measurement of High-Temperature Proton Exchange Membrane Fuel Cell Stack Using Flexible Five-in-One Micro-Sensor
    Lee, Chi-Yuan
    Weng, Fang-Bor
    Kuo, Yzu-Wei
    Tsai, Chao-Hsuan
    Cheng, Yen-Ting
    Cheng, Chih-Kai
    Lin, Jyun-Ting
    SENSORS, 2016, 16 (10)
  • [33] In-situ measurement of in-plane temperature distribution in a single-cell polymer electrolyte fuel cell by thermograph (1st Report, effect assessment of gas flow rate at inlet and gas channel pitch of separator on in-plane temperature distribution and power generation performance)
    Nishimura A.
    Shibuya K.
    Morimoto A.
    Tanaka S.
    Hirota M.
    Nakamura Y.
    Kojima M.
    Narita M.
    Nihon Kikai Gakkai Ronbunshu, B Hen/Transactions of the Japan Society of Mechanical Engineers, Part B, 2010, 76 (762): : 342 - 351