Repositioning and stabilization of the radial styloid process in comminuted fractures of the distal radius using a single approach: the radio-volar double plating technique

被引:5
作者
Jacobi, Matthias [1 ]
Wahl, Peter [1 ]
Kohut, Georges [1 ]
机构
[1] Hop Cantonal Fribourg, Dept Orthopaed Surg, CH-1708 Fribourg, Switzerland
来源
JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH | 2010年 / 5卷
关键词
Distal Radius; Distal Radius Fracture; Styloid Process; Volar Plate; Secondary Dislocation;
D O I
10.1186/1749-799X-5-55
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: A possible difficulty in intra-articular fracture of the distal radius is the displacement tendency of the radial styloid process due to the tension of the brachioradialis tendon. Methods: Ten patients treated within one year for complex distal radius fractures by double-plating technique with a radial buttress plate and volar locking plate, through a single volar approach, were followed prospectively during 24 months. Outcome measures included radiographic follow-up, range of motion, grip strength and score follow-up (VAS, Gartland-Werley score and patient-rated wrist evaluation). Results: Ten patients with intraarticular distal radius fractures with dislocation of the radial styloid process were treated with this technique. This resulted after 24 months in good clinical outcome (mean visual analog scale 0.9; almost symmetric range of motion; mean Gartland-Werley score 2 +/- 3; mean patient-rated wrist evaluation 3.2 +/- 2.4). Radiologic evaluation according to the Dresdner Score revealed anatomic reduction without secondary dislocation during the follow-up and uneventful consolidation. Conclusions: The described technique strongly facilitates anatomic reduction and stable fixation of intra-articular distal radius fractures with dislocation of the radial styloid process and leads to satisfactory clinical and radiographic outcome.
引用
收藏
页数:6
相关论文
共 24 条
  • [1] Palmar locking plate for treatment of unstable dorsal dislocated distal radius fractures
    Arora, R
    Lutz, M
    Fritz, D
    Zimmermann, R
    Oberladstätter, J
    Gabl, M
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2005, 125 (06) : 399 - 404
  • [2] Treatment of unstable distal radial fractures with the volar locking plating system
    Chung, Kevin C.
    Watt, Andrew J.
    Kotsis, Sandra V.
    Margaliot, Zvi
    Haase, Steven C.
    Kim, Myra
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2006, 88A (12) : 2687 - 2694
  • [3] Chung Kevin C, 2007, J Bone Joint Surg Am, V89 Suppl 2 Pt.2, P256
  • [4] EVALUATION OF HEALED COLLES FRACTURES
    GARTLAND, JJ
    WERLEY, CW
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1951, 33-A (04) : 895 - 907
  • [5] HUSKISSON EC, 1982, J RHEUMATOL, V9, P768
  • [6] Fractures of the distal radius treated by internal fixation and early function - A prospective study of 73 consecutive patients
    Jakob, M
    Rikli, DA
    Regazzoni, P
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2000, 82B (03): : 340 - 344
  • [7] Kamano M, 2002, CLIN ORTHOP RELAT R, P403
  • [8] KAPANDJI A, 1976, ANN CHIR, V30, P903
  • [9] Surgical treatment of fractures of the distal radius with plates: a comparison of palmar and dorsal plate position
    Letsch, R
    Infanger, M
    Schmidt, J
    Kock, HJ
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2003, 123 (07) : 333 - 339
  • [10] Patient rating of wrist pain and disability: A reliable and valid measurement tool
    MacDermid, JC
    Turgeon, T
    Richards, RS
    Beadle, M
    Roth, JH
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 1998, 12 (08) : 577 - 586