Conventional X-ray in early arthritis

被引:6
|
作者
Boonen, A [1 ]
van der Heijde, D
机构
[1] Univ Hosp Maastricht, Dept Internal Med, Div Rheumatol, Maastricht, Netherlands
[2] Univ Maastricht, Publ Hlth Res Inst, Maastricht, Netherlands
关键词
D O I
10.1016/j.rdc.2005.07.004
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This article reviews radiographic data from six cohorts of patients with early inflammatory arthritis. Radiographic scoring was not applied for diagnostic purposes but to detect damage as consequence synovitis with poor prognosis, in most studies rheumatoid arthritis. Class scoring methods were applied to detect and quantify damage. Of the patients, 8% to 15% had erosive disease at the first encounter with the rheumatologist, but baseline damage was low in early inflammatory arthritis. Yearly progression in damage score was assessed only in patients with high suspicion of rheumatoid arthritis at baseline or who had a final diagnosis of rheumatoid arthritis at follow-up and varied between 0.5% and 1.7% of the maximal damage of the scoring method per year. The large number of patients with zero values for erosions and lower progression rates will influence sample sizes in clinical trials in early inflammatory arthritis when including radiographic change as an outcome.
引用
收藏
页码:681 / +
页数:19
相关论文
共 50 条
  • [21] Conventional x-ray after shoulder prosthesis
    Wurnig, C.
    RADIOLOGE, 2006, 46 (09): : 748 - 752
  • [22] VALUE OF CONVENTIONAL EYEGLASSES FOR X-RAY PROTECTION
    ARDRAN, GM
    CROOKS, HE
    RADIOLOGY, 1978, 129 (03) : 815 - 816
  • [23] Conventional x-ray diagnostics in manual medicine
    Klett, R.
    MANUELLE MEDIZIN, 2014, 52 (01) : 51 - 62
  • [24] CHROMATOROENTGENOGRAM WITH CONVENTIONAL MEDICAL X-RAY FILM
    TAKAHASHI, S
    TANAKA, Y
    TOHOKU JOURNAL OF EXPERIMENTAL MEDICINE, 1969, 98 (02): : 213 - 214
  • [25] Direct magnifying X-ray technique. An alternative or improvement on conventional X-ray technique
    Wulker, N
    ORTHOPADE, 1997, 26 (03): : 246 - 250
  • [26] Note: Electrochemical cell for in operando X-ray diffraction measurements on a conventional X-ray diffractometer
    Hartung, Steffen
    Bucher, Nicolas
    Bucher, Ramona
    Srinivasan, Madhavi
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2015, 86 (08):
  • [27] Comparison of dual X-ray absorptiometry (DXA), digital X-ray radiogrammetry (DXR) and conventional radiographs in the evaluation of osteoporosis and bone erosions in patients with rheumatoid arthritis
    Jensen, TW
    Hansen, MS
    Jensen, K
    Podenphant, J
    Hansen, TM
    Hyldstrup, L
    ANNALS OF THE RHEUMATIC DISEASES, 2003, 62 : 151 - 152
  • [28] Comparison of dual X-ray absorptiometry (DXA), digital X-ray radiogrammetry (DXR), and conventional radiographs in the evaluation of osteoporosis and bone erosions in patients with rheumatoid arthritis
    Jensen, T
    Hansen, M
    Jensen, KE
    Podenphant, J
    Hansen, TM
    Hyldstrup, L
    SCANDINAVIAN JOURNAL OF RHEUMATOLOGY, 2005, 34 (01) : 27 - 33
  • [29] X-RAY DIAGNOSIS OF JUVENILE RHEUMATOID ARTHRITIS
    LORENZ, K
    BERGER, G
    RADIOLOGIA DIAGNOSTICA, 1969, 10 (06) : 647 - &
  • [30] X-RAY ASSESSMENTS IN RHEUMATOID-ARTHRITIS
    SCOTT, DL
    COULTON, BL
    POPERT, AJ
    BACON, PA
    BRITISH JOURNAL OF RHEUMATOLOGY, 1984, 23 (02): : 116 - 116