Development of new β/α"-Ti-Nb-Zr biocompatible coating with low Young's modulus and high toughness for medical applications

被引:25
|
作者
Frutos, E. [1 ]
Karlik, M. [2 ,3 ]
Jimenez, J. A. [4 ]
Langhansova, H. [5 ,6 ]
Lieskovska, J. [5 ,6 ]
Polcar, T. [1 ,7 ]
机构
[1] Czech Tech Univ, Fac Elect Engn, Dept Control Engn, Tech 2, Prague 6, Czech Republic
[2] Czech Tech Univ, Fac Nucl Sci & Phys Engn, Dept Mat, Trojanova 13, Prague 12000 2, Czech Republic
[3] Charles Univ Prague, Dept Phys Mat, Ke Karlovu 5, Prague 12116 2, Czech Republic
[4] CSIC, Ctr Nacl Invest Met CENIM, Avd Gregorio del Amo 8, Madrid 28040, Spain
[5] Univ South Bohemia, Fac Sci, Branisovska 31, Ceske Budejovice, Czech Republic
[6] Biol Ctr AS CR, Branisovska 31, Ceske Budejovice, Czech Republic
[7] Univ Southampton, Engn Mat, Univ Rd, Southampton SO17 1BJ, Hants, England
基金
英国工程与自然科学研究理事会;
关键词
Biomaterials; Non-toxic beta-rich Ti coatings; Martensitic phase transformation; Rietveld XRD quantification; Transmission electron microscopy; Low Young's modulus; MECHANICAL-PROPERTIES; NANOMECHANICAL PROPERTIES; PHASE-STABILITY; TITANIUM; ALLOYS; BEHAVIOR; HARDNESS; GROWTH; STEEL;
D O I
10.1016/j.matdes.2018.01.014
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Ideal biomaterials to fabricate orthopedic implants, especially for load-bearing joint replacements, should include only non-toxic elements with good biocompatibility, high corrosion resistance and surface bioactivity, together with a good combination of mechanical properties. Based on these criteria, a manufacturing approach based on sputtering techniques can be ideal to develop coatings free of toxic elements tailored for advanced applications on pure titanium or titanium alloys used in biomedical applications. In this work, the ternary Ti-Nb-Zr system was used to develop non-toxic beta-rich Ti coatings with several complex microstructures by careful control of Nb and Zr concentration and deposition parameters, such as bias voltage. Depending on the alloy chemistry and processing, the coating included variable amounts of alpha-, alpha '' and beta-phases of Ti with different morphologies and crystallographic texture. Mechanical properties of every coating is largely determined by the micro-structure present, which is directly related to bias voltage used during sputtering process. Thus, hardness values change as a function of the compressive residual stresses magnitude and Young's modulus decreased from 63 GPa, at 0 V, to 47 GPa, at -63 V, being this value close to human bone (similar to 30 GPa). After that, Young's modulus progressively increases to 89 GPa, at -148 V. On the other hand, bioactivity of the coating is practically doubled when compared to Ti6AL4V alloy. (c) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:44 / 55
页数:12
相关论文
共 50 条
  • [21] Machine learning interatomic potential for the low-modulus Ti-Nb-Zr alloys in the vicinity of dynamical instability
    Mukhamedov, Boburjon
    Tasnadi, Ferenc
    Abrikosov, Igor A.
    MATERIALS & DESIGN, 2025, 253
  • [22] A CALPHAD-type Young's modulus database of Ti-rich Ti-Nb-Zr-Mo system
    Ling, Jinfeng
    Wen, Zhuhao
    Yang, Guiming
    Wang, Yao
    Chen, Weimin
    CALPHAD-COMPUTER COUPLING OF PHASE DIAGRAMS AND THERMOCHEMISTRY, 2021, 73
  • [23] Low Young's modulus in Ti-Nb-Ta-Zr-O alloys: Cold working and oxygen effects
    Tane, M.
    Nakano, T.
    Kuramoto, S.
    Hara, M.
    Niinomi, M.
    Takesue, N.
    Yano, T.
    Nakajima, H.
    ACTA MATERIALIA, 2011, 59 (18) : 6975 - 6988
  • [24] Design and Development of Ti-Zr-Nb-Ta-Ag High Entropy Alloy for Bioimplant Applications
    Hussein, Mohamed Abdrabou
    Azeem, Mohammed Abdul
    Kumar, Arumugam Madhan
    Ankah, Nestor
    ADVANCED ENGINEERING MATERIALS, 2025, 27 (06)
  • [25] Development of low-Young's modulus Ti-Nb-based alloys with Cr addition
    Li, Qiang
    Ma, Guanghao
    Li, Junjie
    Niinomi, Mitsuo
    Nakai, Masaaki
    Koizumi, Yuichro
    Wei, Dai-Xiu
    Kakeshita, Tomoyuki
    Nakano, Takayoshi
    Chiba, Akihiko
    Liu, Xuyan
    Zhou, Kai
    Pan, Deng
    JOURNAL OF MATERIALS SCIENCE, 2019, 54 (11) : 8675 - 8683
  • [26] The bone tissue compatibility of a new Ti-Nb-Sn alloy with a low Young's modulus
    Miura, Keiki
    Yamada, Norikazu
    Hanada, Shuji
    Jung, Taek-Kyun
    Itoi, Eiji
    ACTA BIOMATERIALIA, 2011, 7 (05) : 2320 - 2326
  • [27] β-Type Zr-Nb-Ti biomedical materials with high plasticity and low modulus for hard tissue replacements
    Nie, Li
    Zhan, Yongzhong
    Hu, Tong
    Chen, Xiaoxian
    Wang, Chenghui
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2014, 29 : 1 - 6
  • [28] New biocompatible low modulus and high strength β Ti-Fe-Nb-Sn ultrafine eutectic composites
    Rossi, Mariana C.
    Afonso, Conrado R. M.
    JOURNAL OF MATERIALS RESEARCH AND TECHNOLOGY-JMR&T, 2023, 27 : 7695 - 7704
  • [29] Medium-entropy Zr-Nb-Ti alloys with low magnetic susceptibility, high yield strength, and low elastic modulus through spinodal decomposition for bone-implant applications
    Hua, Zhaolin
    Zhang, Dechuang
    Guo, Lin
    Lin, Sihan
    Li, Yuncang
    Wen, Cuie
    ACTA BIOMATERIALIA, 2024, 190 : 623 - 641
  • [30] Low Springback and Low Young's Modulus in Ti-29Nb-13Ta-4.6Zr Alloy Modified by Mo Addition
    Li, Qiang
    Qi, Qiang
    Li, Junjie
    Nakai, Masaaki
    Niinomi, Mitsuo
    Koizumi, Yuichiro
    Wei, Daixiu
    Yamanaka, Kenta
    Nakano, Takayoshi
    Chiba, Akihiko
    Liu, Xuyan
    Pan, Deng
    MATERIALS TRANSACTIONS, 2019, 60 (09) : 1755 - 1762