Comparative reliability and diagnostic performance of conventional 3T magnetic resonance imaging and 1.5T magnetic resonance arthrography for the evaluation of internal derangement of the hip

被引:45
|
作者
Chopra, A. [1 ]
Grainger, A. J. [1 ,2 ,3 ]
Dube, B. [2 ,3 ]
Evans, R. [2 ,3 ]
Hodgson, R. [2 ,3 ]
Conroy, J. [4 ]
Macdonald, D. [5 ]
Robinson, Philip [1 ,2 ,3 ]
机构
[1] Chapel Allerton Hosp, Leeds Teaching Hosp, Dept Radiol, Leeds LS7 4SA, W Yorkshire, England
[2] Univ Leeds, Leeds, W Yorkshire, England
[3] Chapel Allerton Hosp, NHIR Leeds Musculoskeletal Biomed Res Ctr, Leeds, W Yorkshire, England
[4] Harrogate & Dist NHS Trust, Trauma & Orthopaed Dept, Harrogate, England
[5] Chapel Allerton Hosp, Leeds Teaching Hosp, Trauma & Orthopaed Dept, Leeds, W Yorkshire, England
关键词
Femoroacetabular impingement; MR Arthrography; 3T MRI; Acetabular labral tear; Articular cartilage; ACETABULAR LABRAL TEARS; OSTEOARTHRITIS OUTCOME SCORE; MR ARTHROGRAPHY; FEMOROACETABULAR IMPINGEMENT; CARTILAGE; LESIONS; REPLACEMENT; PREVALENCE; DISABILITY; TESTS;
D O I
10.1007/s00330-017-5069-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To compare the diagnostic accuracy of conventional 3T MRI against 1.5T MR arthrography (MRA) in patients with clinical femoroacetabular impingement (FAI). Sixty-eight consecutive patients with clinical FAI underwent both 1.5T MRA and 3T MRI. Imaging was prospectively analysed by two musculoskeletal radiologists, blinded to patient outcomes and scored for internal derangement including labral and cartilage abnormality. Interobserver variation was assessed by kappa analysis. Thirty-nine patients subsequently underwent hip arthroscopy and surgical results and radiology findings were analysed. Both readers had higher sensitivities for detecting labral tears with 3T MRI compared to 1.5T MRA (not statistically significant p=0.07). For acetabular cartilage defect both readers had higher statistically significant sensitivities using 3T MRI compared to 1.5T MRA (p=0.02). Both readers had a slightly higher sensitivity for detecting delamination with 1.5T MRA compared to 3T MRI, but these differences were not statistically significant (p=0.66). Interobserver agreement was substantial to perfect agreement for all parameters except the identification of delamination (3T MRI showed moderate agreement and 1.5T MRA substantial agreement). Conventional 3T MRI may be at least equivalent to 1.5T MRA in detecting acetabular labrum and possibly superior to 1.5T MRA in detecting cartilage defects in patients with suspected FAI.
引用
收藏
页码:963 / 971
页数:9
相关论文
共 50 条
  • [31] Endometrial cancer: Utility of diffusion-weighted magnetic resonance imaging with background body signal suppression at 3T
    Seo, Jung Min
    Kim, Chan Kyo
    Choi, Dongil
    Park, Byung Kwan
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2013, 37 (05) : 1151 - 1159
  • [32] Middle Cerebral Artery Atherosclerosis and Deep Subcortical Infarction: A 3T Magnetic Resonance Vessel Wall Imaging Study
    Shen, Mi
    Gao, Peiyi
    Zhang, Qian
    Jing, Lina
    Yan, Hongyi
    Li, Hao
    JOURNAL OF STROKE & CEREBROVASCULAR DISEASES, 2018, 27 (11): : 3387 - 3392
  • [33] Reproducibility of in vivo magnetic resonance imaging T1rho and T2 relaxation time measurements of hip cartilage at 3.0T in healthy volunteers
    Nemeth, Angeline
    Di Marco, Lucy
    Boutitie, Florent
    Sdika, Michael
    Grenier, Denis
    Rabilloud, Muriel
    Beuf, Olivier
    Pialat, Jean-Baptiste
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2018, 47 (04) : 1022 - 1033
  • [34] Statistical estimation of T1 relaxation times using conventional magnetic resonance imaging
    Mejia, Amanda F.
    Sweeney, Elizabeth M.
    Dewey, Blake
    Nair, Govind
    Sati, Pascal
    Shea, Colin
    Reich, Daniel S.
    Shinohara, Russell T.
    NEUROIMAGE, 2016, 133 : 176 - 188
  • [35] Quantitative mapping of glenohumeral cartilage in asymptomatic subjects using 3 T magnetic resonance imaging
    Lockard, Carly A.
    Wilson, Katharine J.
    Ho, Charles P.
    Shin, Richard C.
    Katthagen, J. Christoph
    Millett, Peter J.
    SKELETAL RADIOLOGY, 2018, 47 (05) : 671 - 682
  • [36] Comparison of 3T and 7T magnetic resonance imaging for direct visualization of finger flexor pulley rupture: an ex-vivo study
    Bayer, Thomas
    Baechter, Lilly
    Lutter, Christoph
    Janka, Rolf
    Uder, Michael
    Schoeffel, Voelker
    Roemer, Frank W.
    Nagel, Armin M.
    Heiss, Rafael
    SKELETAL RADIOLOGY, 2024, 53 (11) : 2469 - 2476
  • [37] New Arthroscopic Disc Repositioning and Suturing Technique for Treating Internal Derangement of the Temporomandibular Joint: Part II-Magnetic Resonance Imaging Evaluation
    Zhang, Shan-Yong
    Liu, Xiu-Ming
    Yang, Chi
    Cai, Xie-Yi
    Chen, Min-Fie
    Haddad, Majd S.
    Yun, Bai
    Chen, Zhuo-Zhi
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2010, 68 (08) : 1813 - 1817
  • [38] Diagnostic performance of a 3D double-echo steady-state sequence at 3 T using radial reformats for detecting and grading rotator cuff tears: a pilot diagnostic accuracy study with magnetic resonance imaging and arthroscopic correlation
    Osterholt, Ann-Carolin
    Link, Tobias W.
    Abrar, Daniel B.
    Mewes, Alexander D.
    Hufeland, Martin
    Schleich, Christoph
    Bittersohl, Bernd
    ACTA RADIOLOGICA, 2023, 64 (10) : 2768 - 2776
  • [39] Quantification of Corticospinal Tracts with Diffusion Tensor Imaging in Brainstem Surgery: Prognostic Value in 14 Consecutive Cases at 3T Magnetic Resonance Imaging
    Yao, Yuqiang
    Ulrich, Nils H.
    Guggenberger, Roman
    Alzarhani, Yahea A.
    Bertalanffy, Helmut
    Kollias, Spyros S.
    WORLD NEUROSURGERY, 2015, 83 (06) : 1006 - 1014
  • [40] Magnetic resonance elastography (MRE) for measurement of muscle stiffness of the shoulder: feasibility with a 3T MRI system
    Hong, Sun Hwa
    Hong, Suk-Joo
    Yoon, Joon-Shik
    Oh, Chang-Hyun
    Cha, Jang Gyu
    Kim, Hee Kyung
    Bolster, Bradley, Jr.
    ACTA RADIOLOGICA, 2016, 57 (09) : 1099 - 1106