摘要
Parallax error in PET modules can be reduced by measuring the annihilation photon depth of interaction (DOI) in the scintillation crystal on an event-by-event basis. Following implementations described in prior literature, we selected a dual-sided readout PET module design in which SiPMs are placed at both ends of a scintillation array and the ratio of the signal from one photodetector (A) divided by the signal sum of both detectors (A+ B), as well as the plot of Signal A vs. Signal B are used to measure DOI. Our experimental apparatus consisted of a 12x12 scintillation array with 1x1x10mm(3) pixels [from Proteus] with 50 mu Toray Lumirror septa for DOI optimization. Both polished ends of the scintillation array were optically coupled to a 12x12x2mm(3) anti-reflection coated UV fused silica light spreader window [from Edmund Optics]. The reverse side of each window was optically coupled to a low profile (similar to 1mm thick) 4x4 element SiPM with 3 x 3mm(2) active area pixels [SPMArray2 from sensL]. Flexible Printed Circuit (FPC) cables were used to interface the DOI PET module to custom 16 channel differential pre-amplifiers connected to evaluation/power supply boards [SPMArray2-A0 and SPMArray2-A1, respectively, from sensL]. Average DOI resolution of 1.5 +/- 0.1mm FWHM and energy resolution of 20% FWHM was obtained. We conclude that for the limited instances of parallax error expected in realistic PET systems combined with similar to 1mm spatial resolution in the scintillation plane, the obtained result for DOI spatial resolution indicates that similar to 1mm spatial reconstruction resolution PET imaging is possible with the selected technical approach. Applications for such a compact high DOI resolution PET module include a prostate PET probe working in conjunction with a standard clinical PET imager or a dedicated prostate PET imager aiding in prostate cancer diagnosis and biopsy guidance, as well as a carotid artery PET probe imaging vulnerable plaque or a surgical breast imaging probe.
引用
收藏
页码:3442 / 3449
页数:8
相关论文
共 20 条
  • [1] Development of prototype PET scanner using dual-sided readout DOI-PET modules
    Fujita, T.
    Kataoka, J.
    Kishimoto, A.
    Kurei, Y.
    Nishiyama, T.
    Ohshima, T.
    Taya, T.
    JOURNAL OF INSTRUMENTATION, 2014, 9
  • [2] Development of a Dual-Sided Readout DOI-PET Module Using Large-Area Monolithic MPPC-Arrays
    Kishimoto, Aya
    Kataoka, Jun
    Kato, Takuya
    Miura, Takamasa
    Nakamori, Takeshi
    Kamada, Kei
    Nakamura, Shigeyuki
    Sato, Kenichi
    Ishikawa, Yoshitaka
    Yamamura, Kazuhisa
    Kawabata, Nobuyuki
    Yamamoto, Seiichi
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2013, 60 (01) : 38 - 43
  • [3] Optimization of an ultralow-dose high-resolution pediatric PET scanner design based on monolithic scintillators with dual-sided digital SiPM readout: a simulation study
    Mikhaylova, Ekaterina
    Tabacchini, Valerio
    Borghi, Giacomo
    Mollet, Pieter
    D'Hoe, Ester
    Schaart, Dennis R.
    Vandenberghe, Stefaan
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (21): : 8402 - 8418
  • [4] Development of a dual-sided readout DOI-PET detector using 500-μm-pitch 64-ch SiPMs
    Zheng, L.
    Shimazoe, K.
    Yoshihara, Y.
    Koyama, A.
    Takahashi, H.
    JOURNAL OF INSTRUMENTATION, 2019, 14
  • [5] A Dual-Ended Readout Detector Using a Meantime Method for SiPM TOF-DOI PET
    Kang, Han Gyu
    Ko, Guen Bae
    Rhee, June Tak
    Kim, Kyeong Min
    Lee, Jae Sung
    Hong, Seong Jong
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2015, 62 (05) : 1935 - 1943
  • [6] Crystal surface and reflector optimization for the SiPM-based dual-ended readout TOF-DOI PET detector
    Kang, Han Gyu
    Yamaya, Taiga
    Han, Young Been
    Song, Seong Hyun
    Ko, Guen Bae
    Lee, Jae Sung
    Hong, Seong Jong
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2020, 6 (06)
  • [7] SiPM-based dual-ended-readout DOI-TOF PET module based on mean-time method
    Han, Y. B.
    Kang, H. G.
    Song, S. H.
    Ko, G. B.
    Lee, J. S.
    Hong, S. J.
    JOURNAL OF INSTRUMENTATION, 2019, 14 (02)
  • [8] Investigation of a Sub-Millimeter Resolution PET Detector with Depth of Interaction Encoding Using Digital SiPM Single Sided Readout
    Dueppenbecker, Peter Michael
    Lodomez, Sarah
    Haagen, Rainald
    Marsden, Paul K.
    Schulz, Volkmar
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 2252 - +
  • [9] A 32 mm x 32 mm x 22 mm monolithic LYSO:Ce detector with dual-sided digital photon counter readout for ultrahigh-performance TOF-PET and TOF-PET/MRI
    Borghi, Giacomo
    Peet, Bart Jan
    Tabacchini, Valerio
    Schaart, Dennis R.
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (13): : 4929 - 4949
  • [10] Millimeter spatial resolution and sub-200 ps timing in 32 mm x 32 mm x 22 mm monolithic LYSO: Ce crystals with dual-sided digital photon counter readout
    Peet, Bart Jan
    Borghi, Giacomo
    Tabacchini, Valerio
    Schaart, Dennis
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (03)