The wear pattern in metal-on-metal hip prostheses

被引:48
作者
Anissian, HL [1 ]
Stark, A
Good, V
Dahlstrand, H
Clarke, IC
机构
[1] Karolinska Hosp, Dept Orthopaed Surg, S-17176 Stockholm, Sweden
[2] Loma Linda Univ, Med Ctr, Dept Orthopaed Surg, Loma Linda, CA 92350 USA
来源
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH | 2001年 / 58卷 / 06期
关键词
implants; hip-joint simulator; wear; run-in phase; steady-state phase; metal-on-metal prosthesis;
D O I
10.1002/jbm.1068
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The accumulated data suggest that there is a strong correlation between polyethylene wear and osteolysis, which ultimately leads to prosthetic loosening. Second-generation metal-on-metal prostheses have been introduced, with an eye toward resolving this wear-induced osteolysis problem. The metal particles and ions are biologically active and can affect the cell homeostasis. Thus, defining the wear pattern and ratio of a given metal-on-metal prosthesis system is desirable. An early high-wear or run-in phase followed by a low-wear phase or steady state has been suggested for metal-on-metal hip prostheses. The aim of this study was to define the wear pattern of metal-on-metal bearings. The prosthesis systems were tested in a joint simulator. An early accelerated wear phase transformed to a slower wear phase after 700,000 cycles. The run-in and steady-state wear rates for combined head and liner averaged 2.22 mm(3)/Mc and 1.0 mm(3)/ million cycles, respectively. The metal-on-metal prosthesis featured a biphasic wear trend with the wear ratio in run in being more than twofold higher than the steady-state phase. (C) 2001 John Wiley & Sons, Inc.
引用
收藏
页码:673 / 678
页数:6
相关论文
共 50 条
  • [31] Wear of cast metal-metal pairs for total replacement hip prostheses
    Hernández-Rodríguez, MAL
    Mercado-Solís, RD
    Pérez-Unzueta, A
    Martinez-Delgado, DI
    Cantú-Sifuentes, M
    WEAR, 2005, 259 : 958 - 963
  • [32] A numerical study of non-Newtonian transient elastohydrodynamic lubrication of metal-on-metal hip prostheses
    Gao, Leiming
    Dowson, Duncan
    Hewson, Robert W.
    TRIBOLOGY INTERNATIONAL, 2016, 93 : 486 - 494
  • [33] Metal-on-metal hip joint tribology
    Dowson, D
    Jin, ZM
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2006, 220 (H2) : 107 - 118
  • [34] The influence of swing phase load on the electrochemical response, friction, and ion release of metal-on-metal hip prostheses in a friction simulator
    Yan, Y.
    Neville, A.
    Dowson, D.
    Williams, S.
    Fisher, J.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART J-JOURNAL OF ENGINEERING TRIBOLOGY, 2009, 223 (J3) : 303 - 309
  • [35] Long duration metal-on-metal total hip arthroplasties with low wear of the articulating surfaces
    Schmalzried, TP
    Peters, PC
    Maurer, BT
    Bragdon, CR
    Harris, WH
    JOURNAL OF ARTHROPLASTY, 1996, 11 (03) : 322 - 331
  • [36] Characterisation of wear debris from UHMWPE on zirconia ceramic, metal-on-metal and alumina ceramic-on-ceramic hip prostheses generated in a physiological anatomical hip joint simulator
    Tipper, JL
    Firkins, PJ
    Besong, AA
    Barbour, PSM
    Nevelos, J
    Stone, MH
    Ingham, E
    Fisher, J
    WEAR, 2001, 250 : 120 - 128
  • [37] Long-term contact-coupled wear prediction for metal-on-metal total hip joint replacement
    Harun, M. N.
    Wang, F. C.
    Jin, Z. M.
    Fisher, J.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART J-JOURNAL OF ENGINEERING TRIBOLOGY, 2009, 223 (J7) : 993 - 1001
  • [38] Metal-on-metal hip simulator study of increased wear particle surface area due to 'severe' patient activity
    Bowsher, JG
    Hussain, A
    Williams, PA
    Shelton, JC
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2006, 220 (H2) : 279 - 287
  • [39] The tribology of metal-on-metal total hip replacements
    Scholes, SC
    Unsworth, A
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2006, 220 (H2) : 183 - 194
  • [40] Wear in metal-on-metal total disc arthroplasty
    Moghadas, Parshia
    Mahomed, Aziza
    Hukins, David W. L.
    Shepherd, Duncan E. T.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2013, 227 (H4) : 356 - 361