Structure Design and Optimization of the C5-C6 Cervical Intervertebral Fusion Cage Using the Anterior Cervical Plate and Cage Fixation System

被引:3
|
作者
Wang, Jiajia [1 ,2 ]
Qian, Zhihui [2 ]
Cui, Changlei [3 ]
Guo, Zhijun [4 ]
Ren, Luquan [2 ]
机构
[1] Henan Univ Sci & Technol, Coll Agr Equipment Engn, Luoyang, Henan, Peoples R China
[2] Jilin Univ, Minist Educ, Key Lab Bion Engn, Changchun, Jilin, Peoples R China
[3] First Hosp Jilin Univ, Dept Anesthesiol, Changchun, Jilin, Peoples R China
[4] Henan Univ Sci & Technol, Coll Vehicle & Transportat Engn, Luoyang, Henan, Peoples R China
来源
MEDICAL SCIENCE MONITOR | 2020年 / 26卷
基金
中国国家自然科学基金;
关键词
Finite Element Analysis; Postoperative Complications; Prosthesis Implantation; FINITE-ELEMENT-ANALYSIS; INTERBODY FUSION; NECK MOVEMENTS; MODEL; LOAD; VALIDATION; SUBSIDENCE; DISKECTOMY; STABILITY;
D O I
10.12659/MSM.924236
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background: The fifth and sixth cervical vertebra (C5-C6) is the most easily injured segment encountered in clinical practice. The anterior cervical plate and cage (ACPC) fixation system is always used to reconstruct the intervertebral height and maintain the segmental stability. The postoperative effect, such as subsidence, neck pain, and non-fusion, is greatly affected by the cervical cage structure design. This study determined reasonable structure size parameters that present optimized biomechanical properties related to the postoperative subsidence often accompanied with ACPC. Material/Methods: Twenty bionic cages with different structural sizes (distance between the center of the cage and groove, groove depth, and groove width) were designed and analyzed based on the regression optimization design and analysis method combined with FE analysis. Because a previous study showed that greater stresses on the endplate are associated with higher risk of subsidence, the optimization object was selected as the stresses on endplate to lower it. Results: The postoperative stresses on the endplate of all cages with bionic structure design were proved to be low- er than with the original one. The optimal structure size was the distance between the center of the cage and groove=0 mm, groove depth=3 mm, and groove width=4 mm. Regression analysis found the cage with optimized bionic structural parameters resulted in a 22.58% reduction of endplate stress response compared with the original one. Conclusions: The bionic cage with optimized structural sizes can reduce the subsidence risk, suggesting that the optimization method has great potential applications in the biomechanical engineering field.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Anterior Cervical Microdiscectomy and Fusion using Sand-Alone Polyetheretherketone Cage: A Retrospective Study
    Jain, Pradeep Kumar
    Malagi, Sunil
    Shastry, Anoop
    Hegde, Pranoy
    Devamane, Deepankar Ramesh
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2021, 15 (09) : PC23 - PC25
  • [32] Integral Fixation Titanium/Polyetheretherketone Cages for Cervical Arthrodesis: Evolution of Cage Design and Early Radiological Outcomes and Fusion Rates
    Phan, Kevin
    Pelletier, Matthew H.
    Rao, Prashanth J.
    Choy, Wen Jie
    Walsh, William R.
    Mobbs, Ralph J.
    ORTHOPAEDIC SURGERY, 2019, 11 (01) : 52 - 59
  • [33] Interbody Cage Placement Without Plate Supplementation Adjacent to Plated Segments in Multilevel Anterior Cervical Decompression and Fusion
    Odate, Seiichi
    Shikata, Jitsuhiko
    SPINE, 2023, 48 (17) : 1245 - 1252
  • [34] Cervical Alignment After Cervical Arthroplasty with Prestige-LP Disc at C5-C6 Level
    Rong, Xin
    Hu, Xu
    Liu, Hao
    Hong, Ying
    Wang, Beiyu
    WORLD NEUROSURGERY, 2020, 140 : E33 - E40
  • [35] Subsidence ratio after anterior cervical interbody fusion using an intraoperative custom-made cervical cage
    Kim, Dok Ryong
    Moon, Byung Gwan
    Kim, Jae Hoon
    Kang, Hee In
    Lee, Seung Jin
    Kim, Joo Seung
    JOURNAL OF KOREAN NEUROSURGICAL SOCIETY, 2007, 41 (05) : 301 - 305
  • [36] The clinical efficacy of anterior cervical discectomy and fusion with ROI-C device vs. plate-cage in managing traumatic central cord syndrome
    Song, Dawei
    Deng, Zicheng
    Feng, Tao
    Wang, Jinning
    Liu, Yijie
    Wang, Heng
    Yang, Huilin
    Niu, Junjie
    FRONTIERS IN SURGERY, 2023, 9
  • [37] Anterior discectomies and interbody cage fusion without plate fixation for 5-level cervical degenerative disc disease: A 5-year follow-up
    Chu, Cheng-Wei
    Kung, Sui-Sum
    Tsai, Tai-Hsin
    Huang, Tzuu-Yuan
    Hwang, Shiuh-Lin
    KAOHSIUNG JOURNAL OF MEDICAL SCIENCES, 2011, 27 (11) : 524 - 527
  • [38] Comparison study of anterior cervical zero-profile fusion cage (ROI-C) and traditional titanium plate plus fusion technique for the treatment of spinal cord type cervical spondylosis
    Gao, Haoran
    Tian, Zhen
    Wang, Yong
    Lou, Zhaohui
    MEDICINE, 2023, 102 (50) : E36651
  • [39] Effects of facet joint degeneration on stress alterations in cervical spine C5-C6: A finite element analysis
    Wang, Huihao
    Wang, Kuan
    Deng, Zhen
    Li, Xiaofei
    Qin, Yi-Xian
    Zhan, Hongsheng
    Niu, Wenxin
    MATHEMATICAL BIOSCIENCES AND ENGINEERING, 2019, 16 (06) : 7447 - 7457
  • [40] Assessing Surgical Outcomes for Cage Plate System versus Stand-Alone Cage in Anterior Cervical Discectomy and Fusion: A Systematic Review and Meta-Analysis
    Elias, Elias
    Daoud, Ali
    Smith, Justin
    Elias, Charbel
    Nasser, Zeina
    WORLD NEUROSURGERY, 2024, 185 : 150 - 164