Study on the characteristics of X-ray spectra in imaging diagnosis using Monte Carlo simulations

被引:2
作者
Khanh Ai Tran [1 ]
Loan Thi Hong Truong [1 ]
Nhon Van Mai [1 ]
Phuong Nguyen Dang [2 ]
Dung Thi Thuy Vo [3 ]
机构
[1] VNU HCM Univ Sci, Fac Phys & Engn Phys, Ho Chi Minh City 700000, Vietnam
[2] Univ Freiburg, Inst Phys, D-79085 Freiburg, Germany
[3] Ho Chi Minh City Univ Pedag, Ho Chi Minh City 700000, Vietnam
关键词
X-ray spectrum; Simulation; MCNP5; code; DETECTOR; TUBES;
D O I
10.3938/jkps.69.1168
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
X-rays are widely used in diagnostic imaging such as radiography and computed tomography. An understanding of the X-ray spectrum is essential for estimating the dose absorbed by the patient and for improving image quality. In this research, X-ray emission spectra were investigated by using two different approaches: a Monte Carlo method using the MCNP5 code and a semi-empirical calculation with SpekCalc software. The results were compared with each other to validate the Monte Carlo simulation of the X-ray spectra, so that the simulation model can be applied to estimating the dose rate distribution in X-ray imaging. The obtained results show good agreement between the two approaches, but some divergence is still observed in the characteristic X-ray peaks. In addition, the influence of X-ray tube parameters such as the peak voltage, filter, anode angle and target material on of the beam quality was investigated.
引用
收藏
页码:1168 / 1174
页数:7
相关论文
共 50 条
  • [41] Calculation of the exposure buildup factors for x-ray photons with continuous energy spectrum using Monte Carlo code
    Rafiei, Mustafa Mohammad
    Tavakoli-Anbaran, Hossein
    JOURNAL OF RADIOLOGICAL PROTECTION, 2018, 38 (01) : 207 - 217
  • [42] Monte Carlo determination of a nanoDot OSLD response using quality index for diagnostic kilovoltage X-ray beams
    Araki, Fujio
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 84 : 101 - 108
  • [43] Comparative study of Curiementor ionization chambers using Monte Carlo simulations
    Simoes, Catarina
    Caldeira, Margarida
    Oliveira, Carlos
    APPLIED RADIATION AND ISOTOPES, 2010, 68 (06) : 1121 - 1127
  • [44] Dosimetry and Monte Carlo modelling of the Papillon plus contact X-ray brachytherapy device
    Colson, Dries
    Yalvac, Burak
    Weterings, Jan
    Verrijssen, An-Sofie
    van Haaren, Paul
    Bellezzo, Murillo
    Berbee, Maaike
    Van Limbergen, Evert J.
    Croce, Olivier
    Verhaegen, Frank
    Reniers, Brigitte
    BRACHYTHERAPY, 2024, 23 (05) : 535 - 548
  • [45] Monte Carlo dosimetry for forthcoming clinical trials in x-ray microbeam radiation therapy
    Martinez-Rovira, I.
    Sempau, J.
    Fernandez-Varea, J. M.
    Bravin, A.
    Prezado, Y.
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (15) : 4375 - 4388
  • [46] Current status and new horizons in Monte Carlo simulation of X-ray CT scanners
    Habib Zaidi
    Mohammad Reza Ay
    Medical & Biological Engineering & Computing, 2007, 45 : 809 - 817
  • [47] Dual-energy computed tomography imaging with megavoltage and kilovoltage X-ray spectra
    Jadick, Giavanna
    Schlafly, Geneva
    La Riviere, Patrick J.
    JOURNAL OF MEDICAL IMAGING, 2024, 11 (02)
  • [48] Current status and new horizons in Monte Carlo simulation of X-ray CT scanners
    Zaidi, Habib
    Ay, Mohammad Reza
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2007, 45 (09) : 809 - 817
  • [49] CMOS detector systems for soft X-ray imaging diagnosis
    Wei, Minxi
    Hou, Lifei
    Yang, Guohong
    Liu, Shenye
    Yang, Guohong, 1600, Editorial Office of High Power Laser and Particle Beams (26):
  • [50] Combined FDTD-Monte Carlo analysis and a novel design for ZnO scintillator rods in polycarbonate membrane for X-ray imaging
    Mohammadian-Behbahani, Mohammad-Reza
    Saramad, Shahyar
    Mohammadi, Mohammad
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2017, 853 : 78 - 84