Assessment of left ventricular systolic function using contrast two-dimensional echocardiography with a high-frequency transducer in the awake murine model of myocardial infarction

被引:10
作者
Suehiro, K
Takuma, S
Shimizu, J
Hozumi, T
Yano, H
Cardinale, C
DiTullio, MR
Wang, J
Smith, CR
Burkhoff, D
Homma, S
机构
[1] Columbia Univ, Dept Med, Div Cardiol, New York, NY 10032 USA
[2] Columbia Univ, Dept Surg, New York, NY 10032 USA
来源
JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION | 2001年 / 65卷 / 11期
关键词
echocardiography; left ventricular function; mouse; myocardial infarction;
D O I
10.1253/jcj.65.979
中图分类号
N09 [自然科学史]; B [哲学、宗教];
学科分类号
01 ; 0101 ; 010108 ; 060207 ; 060305 ; 0712 ;
摘要
The estimation of global left ventricular function using M-mode echocardiography has technical limitations in the murine model of myocardial infarction (MI), but the recent improvements in 2-dimensional (2-D) echocardiography using a high-frequency transducer provide more accessible images. Furthermore, intravenous injection of contrast agent has the additional benefit of enhancing the endocardial border in the murine heart. The present study was designed to evaluate the value of 2-D echocardiography with intravenous injection of contrast agent in the assessment of global systolic function of the murine heart with MI. Two-dimensional and M-mode echocardiography without and with intravenous injection of contrast agent (Optison, 0.1-0.15 ml) were performed in 76 awake mice 2 days before and 2 days after left coronary artery ligation. Fractional shortening (FS) was calculated from the end-diastolic and end-systolic diameters on M-mode echocardiography, and fractional area change (FAC) from the end-diastolic and end-systolic areas on 2-D echocardiography. Both FS and FAC were compared with the areas of hypoperfusion observed in the pathological samples. The use of contrast agent improved the number of hearts that could be evaluated by both the M-mode and 2-D method (M-mode: non-contrast 87% vs contrast 99%, p<0.01; 2-D: non-contrast 26% vs contrast 89%, p<0.001). FAC from the 2-D method correlated better with the region of hypoperfusion in the pathological samples than did FS from the M-mode method (FAC: r=0.84 vs FS: r=0.51). In conclusion, FAC obtained from 2-D contrast echocardiography is useful for noninvasive assessment of global systolic function in infarcted murine hearts and can be used to serially assess systolic function in various models of the murine heart.
引用
收藏
页码:979 / 983
页数:5
相关论文
共 31 条
[21]   DETERMINATION OF LEFT-VENTRICULAR EJECTION FRACTION BY VISUAL ESTIMATION DURING REAL-TIME TWO-DIMENSIONAL ECHOCARDIOGRAPHY [J].
RICH, S ;
SHEIKH, A ;
GALLASTEGUI, J ;
KONDOS, GT ;
MASON, T ;
LAM, W .
AMERICAN HEART JOURNAL, 1982, 104 (03) :603-606
[22]   MOLECULAR AND PHYSIOLOGICAL ALTERATIONS IN MURINE VENTRICULAR DYSFUNCTION [J].
ROCKMAN, HA ;
ONO, S ;
ROSS, RS ;
JONES, LR ;
KARIMI, M ;
BHARGAVA, V ;
ROSS, J ;
CHIEN, KR .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1994, 91 (07) :2694-2698
[23]   Matrix metalloproteinase inhibition attenuates early left ventricular enlargement after experimental myocardial infarction in mice [J].
Rohde, LE ;
Ducharme, A ;
Arroyo, LH ;
Aikawa, M ;
Sukhova, GH ;
Lopez-Anaya, A ;
McClure, KF ;
Mitchell, PG ;
Libby, P ;
Lee, RT .
CIRCULATION, 1999, 99 (23) :3063-3070
[24]   Three-dimensional echocardiographic assessment of left ventricular wall motion abnormalities in mouse myocardial infarction [J].
Scherrer-Crosbie, M ;
Steudel, W ;
Hunziker, PR ;
Liel-Cohen, N ;
Ullrich, R ;
Zapol, WM ;
Picard, MH .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 1999, 12 (10) :834-840
[25]   NONVOLUMETRIC ASSESSMENT OF VENTRICULAR-FUNCTION BY TWO-DIMENSIONAL ECHOCARDIOGRAPHY IN PATIENTS WITH CORONARY-ARTERY DISEASE [J].
SHEA, PM ;
GLOVER, MU ;
HANDLER, JB ;
NELSON, DP ;
VIEWEG, WVR .
JOURNAL OF CLINICAL ULTRASOUND, 1983, 11 (08) :415-420
[26]   Gated magnetic resonance imaging of normal and hypertrophied murine hearts [J].
Siri, FM ;
Jelicks, LA ;
Leinwand, LA ;
Gardin, JM .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 1997, 272 (05) :H2394-H2402
[27]   Real-time, 3-dimensional echocardiography acquires all standard 2-dimensional images from 2 volume sets: A clinical demonstration in 45 patients [J].
Takuma, S ;
Zwas, DR ;
Fard, A ;
Wu, H ;
Chaudhry, H ;
Di Tullio, MR ;
Ota, T ;
Homma, S .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 1999, 12 (01) :1-6
[28]   Transthoracic echocardiography in models of cardiac disease in the mouse [J].
Tanaka, N ;
Dalton, N ;
Mao, L ;
Rockman, HA ;
Peterson, KL ;
Gottshall, KR ;
Hunter, JJ ;
Chien, KR ;
Ross, J .
CIRCULATION, 1996, 94 (05) :1109-1117
[29]   COMPARISON OF TWO-DIMENSIONAL ECHOCARDIOGRAPHY WITH GATED RADIONUCLIDE VENTRICULOGRAPHY IN THE EVALUATION OF GLOBAL AND REGIONAL LEFT-VENTRICULAR FUNCTION IN ACUTE MYOCARDIAL-INFARCTION [J].
VANREET, RE ;
QUINONES, MA ;
POLINER, LR ;
NELSON, JG ;
WAGGONER, AD ;
KANON, D ;
LUBETKIN, SJ ;
PRATT, CM ;
WINTERS, WL .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1984, 3 (02) :243-252
[30]   Evaluation of global and regional left ventricular function using technetium-99m sestamibi ECG-gated single-photon emission tomography [J].
Yang, KTA ;
Chen, HD .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1998, 25 (05) :515-521