Development and validation of a hydrophilic interaction liquid chromatography-tandem mass spectrometry method for the quantification of lipid-related extracellular metabolites in Saccharomyces cerevisiae

被引:13
|
作者
Sun, Tao [2 ]
Wetzel, Stephanie J. [2 ]
Johnson, Mitchell E. [2 ]
Surlow, Beth A. [1 ]
Patton-Vogt, Jana [1 ]
机构
[1] Duquesne Univ, Dept Biol Sci, Pittsburgh, PA 15282 USA
[2] Duquesne Univ, Dept Chem & Biochem, Pittsburgh, PA 15282 USA
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2012年 / 897卷
基金
美国国家科学基金会;
关键词
HILIC-MS/MS; Glycerophospholipid metabolites; Metabolomics; Saccharomyces cerevisiae; Metabolic footprinting; FUNCTIONAL GENOMICS; GENE DISRUPTION; BUDDING YEAST; IN-VIVO; METABOLOMICS; PHOSPHATIDYLCHOLINE; GLYCEROPHOSPHOINOSITOL; MUTANTS; SEPARATION; TURNOVER;
D O I
10.1016/j.jchromb.2012.03.034
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A highly sensitive hydrophilic interaction liquid chromatography-tandem mass spectrometry (HILIC-MS/MS) method was developed and validated for the quantification of glycerophosphoinositol (GroPIns), glycerophosphocholine (GroPCho), glycerol 3-phosphate (GroP), inositol, and choline in the extracellular medium of Saccharomyces cerevisiae. The media samples were pretreated with a single two-phase liquid extraction. Chromatographic separation was achieved on a Waters Xbridge HILIC (150 mm x 4.6 mm, 5 mu m) column under isocratic conditions using a mobile phase composed of acetonitrile/water, 70:30 (v/v) with 10 mM ammonium acetate (pH adjusted to 4.5) at a flow-rate of 0.5 mL/min. Using a triple quadrupole tandem mass spectrometer, samples were detected in multiple reaction monitoring (MRM) mode via an electrospray ionization (ESI) source. The calibration curves were linear (r(2) >= 0.995) over the range of 0.5-150 nM, with the lower limit of quantitation validated at 0.5 nM for all analytes. The intra- and inter-day precision (calculated by coefficient of variation, CV%) ranged from 1.24 to 5.88% and 2.46 to 9.77%, respectively, and intra- and inter-day accuracy (calculated by relative error, RE%) was between -8.42 to 8.22% and -9.35 to 6.62%, respectively, at all quality control levels. The extracellular metabolites were stable throughout various storage stability studies. The fully validated method was successfully applied to determine the extracellular levels of phospholipid-related metabolites in S. cerevisiae. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 9
页数:9
相关论文
共 50 条
  • [21] Determination of tiapride in human plasma using hydrophilic interaction liquid chromatography-tandem mass spectrometry
    Ya Moon
    Bok Paek
    Hui-Hyun Kim
    Hye Young Ji
    Hye Won Lee
    Hyoung-Geun Park
    Hye Suk Lee
    Archives of Pharmacal Research, 2004, 27 : 901 - 905
  • [22] Determination of tiapride in human plasma using hydrophilic interaction liquid chromatography-tandem mass spectrometry
    Moon, Y
    Paek, IB
    Kim, HH
    Ji, HY
    Lee, HW
    Park, HG
    Lee, HS
    ARCHIVES OF PHARMACAL RESEARCH, 2004, 27 (09) : 901 - 905
  • [23] Hydrophilic interaction liquid chromatography-tandem mass spectrometry for the determination of levofloxacin in human plasma.
    Ji, Hye Young
    Jeong, Dong Won
    Kim, Young Hoon
    Kim, Hui-Hyun
    Sohn, Dong-Ryul
    Lee, Hye Suk
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2006, 41 (02) : 622 - 627
  • [24] Development and validation of a liquid chromatography-tandem mass spectrometry method to determine intact glucosinolates in bee pollen
    Ares, Ana M.
    Nozal, Maria J.
    Bernal, Jose
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2015, 1000 : 49 - 56
  • [25] Optimization and validation of a hydrophilic interaction liquid chromatography-tandem mass spectrometry method for the determination of 13 top-prescribed pharmaceuticals in influent wastewater
    van Nuijs, Alexander L. N.
    Tarcomnicu, Isabela
    Simons, Ward
    Bervoets, Lieven
    Blust, Ronny
    Jorens, Philippe G.
    Neels, Hugo
    Covaci, Adrian
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 398 (05) : 2211 - 2222
  • [26] A full validated hydrophilic interaction liquid chromatography-tandem mass spectrometric method for the quantification of oxaliplatin in human plasma ultrafiltrates
    Ito, Hajime
    Yamaguchi, Hiroaki
    Fujikawa, Asuka
    Tanaka, Nobuaki
    Furugen, Ayako
    Miyamori, Kazuaki
    Takahashi, Natsuko
    Ogura, Jiro
    Kobayashi, Masaki
    Yamada, Takehiro
    Mano, Nariyasu
    Iseki, Ken
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2012, 71 : 99 - 103
  • [27] A single-run, rapid polarity switching method for simultaneous quantification of cardiovascular disease-related metabolites using liquid chromatography-tandem mass spectrometry
    Tang, Yueming
    Wang, Siming
    Zhang, Wenduo
    Yang, Ruiyue
    Yu, Xue
    Wang, Xinyue
    Mu, Hongna
    Li, Hongxia
    Ji, Fusui
    Chen, Wenxiang
    Dong, Jun
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2021, 461
  • [28] Metabolic profiling workflow for cell extracts by targeted hydrophilic interaction liquid chromatography-tandem mass spectrometry
    Serafimov, Kristian
    Laemmerhofer, Michael
    JOURNAL OF CHROMATOGRAPHY A, 2022, 1684
  • [29] Determination of adenosine and its modifications in urine and plasma from breast cancer patients by hydrophilic interaction liquid chromatography-tandem mass spectrometry
    Zhang, Xiaoxiao
    Hu, Yiqiu
    Hong, Xiujuan
    Wang, Mingwei
    Fang, Zhihao
    Cao, Xiaoji
    Jiang, Kezhi
    Guo, Cheng
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2022, 1209
  • [30] Development and validation of a hydrophilic interaction ultra-high-performance liquid chromatography-tandem mass spectrometry method for rapid simultaneous determination of 19 free amino acids in rat plasma and urine
    Wen, Yongqing
    Yuan, Xuemei
    Qin, Feng
    Zhao, Longshan
    Xiong, Zhili
    BIOMEDICAL CHROMATOGRAPHY, 2019, 33 (01)