Diagnostic Performance of Noninvasive Myocardial Perfusion Imaging Using Single-Photon Emission Computed Tomography, Cardiac Magnetic Resonance, and Positron Emission Tomography Imaging for the Detection of Obstructive Coronary Artery Disease A Meta-Analysis

被引:329
|
作者
Jaarsma, Caroline [1 ,2 ,3 ]
Leiner, Tim [2 ,3 ]
Bekkers, Sebastiaan C. [1 ,3 ]
Crijns, Harry J. [1 ,3 ]
Wildberger, Joachim E. [2 ,3 ]
Nagel, Eike [5 ]
Nelemans, Patricia J. [3 ,4 ]
Schalla, Simon [1 ,3 ]
机构
[1] Maastricht Univ Med Ctr, Dept Cardiol, NL-6202 AZ Maastricht, Netherlands
[2] Maastricht Univ Med Ctr, Dept Radiol, NL-6202 AZ Maastricht, Netherlands
[3] Maastricht Univ Med Ctr, Cardiovasc Res Inst Maastricht, NL-6202 AZ Maastricht, Netherlands
[4] Maastricht Univ Med Ctr, Dept Epidemiol, NL-6202 AZ Maastricht, Netherlands
[5] Kings Coll London, Div Imaging Sci, London WC2R 2LS, England
关键词
cardiovascular magnetic resonance imaging; meta-analysis; perfusion; positron emission tomography; single-photon emission computed tomography; PROGNOSTIC VALUE; ATTENUATION CORRECTION; EXERCISE ECHOCARDIOGRAPHY; STRESS PERFUSION; LOW LIKELIHOOD; FLOW RESERVE; ANGIOGRAPHY; PROGRESSION; GUIDELINES; INFARCTION;
D O I
10.1016/j.jacc.2011.12.040
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives This study aimed to determine the diagnostic accuracy of the 3 most commonly used noninvasive myocardial perfusion imaging modalities, single-photon emission computed tomography (SPECT), cardiac magnetic resonance (CMR), and positron emission tomography (PET) perfusion imaging for the diagnosis of obstructive coronary artery disease (CAD). Additionally, the effect of test and study characteristics was explored. Background Accurate detection of obstructive CAD is important for effective therapy. Noninvasive myocardial perfusion imaging is increasingly being applied to gauge the severity of CAD. Methods Studies published between 1990 and 2010 identified by PubMed search and citation tracking were examined. A study was included if a perfusion imaging modality was used as a diagnostic test for the detection of obstructive CAD and coronary angiography as the reference standard (>= 50% diameter stenosis). Results Of the 3,635 citations, 166 articles (n = 17,901) met the inclusion criteria: 114 SPECT, 37 CMR, and 15 PET articles. There were not enough publications on other perfusion techniques such as perfusion echocardiography and computed tomography to include these modalities into the study. The patient-based analysis per imaging modality demonstrated a pooled sensitivity of 88% (95% confidence interval [CI]: 88% to 89%), 89% (95% CI: 88% to 91%), and 84% (95% CI: 81% to 87%) for SPECT, CMR, and PET, respectively; with a pooled specificity of 61% (95% CI: 59% to 62%), 76% (95% CI: 73% to 78%), and 81% (95% CI: 74% to 87%). This resulted in a pooled diagnostic odds ratio (DOR) of 15.31 (95% CI: 12.66 to 18.52; I-2 63.6%), 26.42 (95% CI: 17.69 to 39.47; I-2 58.3%), and 36.47 (95% CI: 21.48 to 61.92; I-2 0%). Most of the evaluated test and study characteristics did not affect the ranking of diagnostic performances. Conclusions SPECT, CMR, and PET all yielded a high sensitivity, while a broad range of specificity was observed. SPECT is widely available and most extensively validated; PET achieved the highest diagnostic performance; CMR may provide an alternative without ionizing radiation and a similar diagnostic accuracy as PET. We suggest that referring physicians consider these findings in the context of local expertise and infrastructure. (J Am Coll Cardiol 2012;59:1719-28) (C) 2012 by the American College of Cardiology Foundation
引用
收藏
页码:1719 / 1728
页数:10
相关论文
共 50 条
  • [21] Impact of cardiac hybrid single-photon emission computed tomography/computed tomography imaging on choice of treatment strategy in coronary artery disease
    Pazhenkottil, Aju P.
    Nkoulou, Rene N.
    Ghadri, Jelena-Rima
    Herzog, Bernhard A.
    Kueest, Silke M.
    Husmann, Lars
    Wolfrum, Mathias
    Goetti, Robert
    Buechel, Ronny R.
    Gaemperli, Oliver
    Luescher, Thomas F.
    Kaufmann, Philipp A.
    EUROPEAN HEART JOURNAL, 2011, 32 (22) : 2824 - 2829
  • [22] Phase Analysis Using Gated Myocardial Perfusion Single-Photon Emission Computed Tomography Imaging for Evaluating Cardiac Dyssynchrony
    Matsuo, Shinro
    CIRCULATION JOURNAL, 2012, 76 (08) : 1832 - 1833
  • [23] Single-Photon Emission Computed Tomography Perfusion Imaging Is Using a "Warranty Period" Warranted?
    Kottam, Anupama
    Williams, Kim Allan, Sr.
    CIRCULATION-CARDIOVASCULAR IMAGING, 2010, 3 (05) : 505 - 506
  • [24] Diagnostic performance of myocardial perfusion single-photon emission computed tomography with attenuation correction
    Plachcinska, Anna
    Wlodarczyk, Michal
    Kovacevic-Kusmierek, Katarzyna
    Bienkiewicz, Malgorzata
    Drozdz, Jaroslaw
    Chizynski, Krzysztof
    Kasprzak, Jaroslaw D.
    Peruga, Jan Z.
    Kusmierek, Jacek
    KARDIOLOGIA POLSKA, 2016, 74 (01) : 32 - 39
  • [25] Imaging technology for myocardial perfusion single-photon emission computed tomography 2018 in Japan
    Shibutani, Takayuki
    Okuda, Koichi
    Ichikawa, Hajime
    Kato, Toyohiro
    Miwa, Kenta
    Tsushima, Hiroyuki
    Onoguchi, Masahisa
    Nagaki, Akio
    JAPANESE JOURNAL OF RADIOLOGY, 2020, 38 (03) : 274 - 282
  • [26] MR-IMPACT II: Magnetic Resonance Imaging for Myocardial Perfusion Assessment in Coronary artery disease Trial: perfusion-cardiac magnetic resonance vs. single-photon emission computed tomography for the detection of coronary artery disease: a comparative multicentre, multivendor trial
    Schwitter, Juerg
    Wacker, Christian M.
    Wilke, Norbert
    Al-Saadi, Nidal
    Sauer, Ekkehart
    Huettle, Kalman
    Schoenberg, Stefan O.
    Luchner, Andreas
    Strohm, Oliver
    Ahlstrom, Hakan
    Dill, Thorsten
    Hoebel, Nadja
    Simor, Tamas
    EUROPEAN HEART JOURNAL, 2013, 34 (10) : 775 - 781
  • [27] Procedure guidelines for radionuclide myocardial perfusion imaging with single-photon emission computed tomography
    Arumugam, Parthiban
    Harbinson, Mark
    Reyes, Eliana
    Sabharwal, Nikhant
    Tonge, Christine
    Underwood, Richard
    Kelion, Andrew
    NUCLEAR MEDICINE COMMUNICATIONS, 2013, 34 (08) : 813 - 826
  • [28] Diagnostic imaging for pancreatic cancer - Computed tomography, magnetic resonance imaging, and positron emission tomography
    Saisho, H
    Yamaguchi, T
    PANCREAS, 2004, 28 (03) : 273 - 278
  • [29] Use of cardiac magnetic resonance imaging and single photon emission computed tomography for the diagnosis of stable coronary artery disease in Switzerland
    Jeanne, De Fay de Lavallaz
    Michael, Zellweger J.
    Stefan, Felder
    SWISS MEDICAL WEEKLY, 2019, 149
  • [30] Impact of Positron Emission Tomography Viability Imaging: Guided Revascularizations on Clinical Outcomes in Patients With Myocardial Scar on Single-Photon Emission Computed Tomography Scans
    Park, Jong Sung
    Lee, Jang Hoon
    Hong, Chae Moon
    Park, Bo Eun
    Park, Yoon Jung
    Kim, Hong Nyun
    Kim, Namkyun
    Jang, Se Yong
    Bae, Myung Hwan
    Yang, Dong Heon
    Park, Hun Sik
    Cho, Yongkeun
    JOURNAL OF KOREAN MEDICAL SCIENCE, 2023, 38 (46)