Diagnostic Performance of Noninvasive Myocardial Perfusion Imaging Using Single-Photon Emission Computed Tomography, Cardiac Magnetic Resonance, and Positron Emission Tomography Imaging for the Detection of Obstructive Coronary Artery Disease A Meta-Analysis

被引:329
|
作者
Jaarsma, Caroline [1 ,2 ,3 ]
Leiner, Tim [2 ,3 ]
Bekkers, Sebastiaan C. [1 ,3 ]
Crijns, Harry J. [1 ,3 ]
Wildberger, Joachim E. [2 ,3 ]
Nagel, Eike [5 ]
Nelemans, Patricia J. [3 ,4 ]
Schalla, Simon [1 ,3 ]
机构
[1] Maastricht Univ Med Ctr, Dept Cardiol, NL-6202 AZ Maastricht, Netherlands
[2] Maastricht Univ Med Ctr, Dept Radiol, NL-6202 AZ Maastricht, Netherlands
[3] Maastricht Univ Med Ctr, Cardiovasc Res Inst Maastricht, NL-6202 AZ Maastricht, Netherlands
[4] Maastricht Univ Med Ctr, Dept Epidemiol, NL-6202 AZ Maastricht, Netherlands
[5] Kings Coll London, Div Imaging Sci, London WC2R 2LS, England
关键词
cardiovascular magnetic resonance imaging; meta-analysis; perfusion; positron emission tomography; single-photon emission computed tomography; PROGNOSTIC VALUE; ATTENUATION CORRECTION; EXERCISE ECHOCARDIOGRAPHY; STRESS PERFUSION; LOW LIKELIHOOD; FLOW RESERVE; ANGIOGRAPHY; PROGRESSION; GUIDELINES; INFARCTION;
D O I
10.1016/j.jacc.2011.12.040
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives This study aimed to determine the diagnostic accuracy of the 3 most commonly used noninvasive myocardial perfusion imaging modalities, single-photon emission computed tomography (SPECT), cardiac magnetic resonance (CMR), and positron emission tomography (PET) perfusion imaging for the diagnosis of obstructive coronary artery disease (CAD). Additionally, the effect of test and study characteristics was explored. Background Accurate detection of obstructive CAD is important for effective therapy. Noninvasive myocardial perfusion imaging is increasingly being applied to gauge the severity of CAD. Methods Studies published between 1990 and 2010 identified by PubMed search and citation tracking were examined. A study was included if a perfusion imaging modality was used as a diagnostic test for the detection of obstructive CAD and coronary angiography as the reference standard (>= 50% diameter stenosis). Results Of the 3,635 citations, 166 articles (n = 17,901) met the inclusion criteria: 114 SPECT, 37 CMR, and 15 PET articles. There were not enough publications on other perfusion techniques such as perfusion echocardiography and computed tomography to include these modalities into the study. The patient-based analysis per imaging modality demonstrated a pooled sensitivity of 88% (95% confidence interval [CI]: 88% to 89%), 89% (95% CI: 88% to 91%), and 84% (95% CI: 81% to 87%) for SPECT, CMR, and PET, respectively; with a pooled specificity of 61% (95% CI: 59% to 62%), 76% (95% CI: 73% to 78%), and 81% (95% CI: 74% to 87%). This resulted in a pooled diagnostic odds ratio (DOR) of 15.31 (95% CI: 12.66 to 18.52; I-2 63.6%), 26.42 (95% CI: 17.69 to 39.47; I-2 58.3%), and 36.47 (95% CI: 21.48 to 61.92; I-2 0%). Most of the evaluated test and study characteristics did not affect the ranking of diagnostic performances. Conclusions SPECT, CMR, and PET all yielded a high sensitivity, while a broad range of specificity was observed. SPECT is widely available and most extensively validated; PET achieved the highest diagnostic performance; CMR may provide an alternative without ionizing radiation and a similar diagnostic accuracy as PET. We suggest that referring physicians consider these findings in the context of local expertise and infrastructure. (J Am Coll Cardiol 2012;59:1719-28) (C) 2012 by the American College of Cardiology Foundation
引用
收藏
页码:1719 / 1728
页数:10
相关论文
共 50 条
  • [1] Diagnostic performance of myocardial perfusion imaging with conventional and CZT single-photon emission computed tomography in detecting coronary artery disease: A meta-analysis
    Cantoni, Valeria
    Green, Roberta
    Acampa, Wanda
    Zampella, Emilia
    Assante, Roberta
    Nappi, Carmela
    Gaudieri, Valeria
    Mannarino, Teresa
    Cuocolo, Renato
    Di Vaia, Eugenio
    Petretta, Mario
    Cuocolo, Alberto
    JOURNAL OF NUCLEAR CARDIOLOGY, 2021, 28 (02) : 698 - 715
  • [2] Diagnostic performance of myocardial perfusion imaging with conventional and CZT single-photon emission computed tomography in detecting coronary artery disease: A meta-analysis
    Valeria Cantoni
    Roberta Green
    Wanda Acampa
    Emilia Zampella
    Roberta Assante
    Carmela Nappi
    Valeria Gaudieri
    Teresa Mannarino
    Renato Cuocolo
    Eugenio Di Vaia
    Mario Petretta
    Alberto Cuocolo
    Journal of Nuclear Cardiology, 2021, 28 : 698 - 715
  • [3] Diagnostic accuracy of myocardial perfusion imaging with single photon emission computed tomography and positron emission tomography: a comparison with coronary angiography
    Husmann, Lars
    Wiegand, Mischa
    Valenta, Ines
    Gaemperli, Oliver
    Schepis, Tiziano
    Siegrist, Patrick T.
    Namdar, Mehdi
    Wyss, Christophe A.
    Alkadhi, Hatem
    Kaufmann, Philipp A.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2008, 24 (05) : 511 - 518
  • [4] Diagnostic performance of noninvasive imaging using computed tomography, magnetic resonance imaging, and positron emission tomography for the detection of ovarian cancer: a meta-analysis
    Xiaoxiao Li
    Luqin Wang
    Pengfei Guo
    Qiangkun Sun
    Yating Zhang
    Cheng Chen
    Yulong Zhang
    Annals of Nuclear Medicine, 2023, 37 : 541 - 550
  • [5] Diagnostic performance of noninvasive imaging using computed tomography, magnetic resonance imaging, and positron emission tomography for the detection of ovarian cancer: a meta-analysis
    Li, Xiaoxiao
    Wang, Luqin
    Guo, Pengfei
    Sun, Qiangkun
    Zhang, Yating
    Chen, Cheng
    Zhang, Yulong
    ANNALS OF NUCLEAR MEDICINE, 2023, 37 (10) : 541 - 550
  • [6] Diagnostic accuracy of myocardial perfusion imaging with single photon emission computed tomography and positron emission tomography: a comparison with coronary angiography
    Lars Husmann
    Mischa Wiegand
    Ines Valenta
    Oliver Gaemperli
    Tiziano Schepis
    Patrick T. Siegrist
    Mehdi Namdar
    Christophe A. Wyss
    Hatem Alkadhi
    Philipp A. Kaufmann
    The International Journal of Cardiovascular Imaging, 2008, 24 : 511 - 518
  • [7] Diagnostic Accuracy of Cardiac Positron Emission Tomography Versus Single Photon Emission Computed Tomography for Coronary Artery Disease A Bivariate Meta-Analysis
    Parker, Matthew W.
    Iskandar, Aline
    Limone, Brendan
    Perugini, Andrew
    Kim, Hyejin
    Jones, Charles
    Calamari, Brian
    Coleman, Craig I.
    Heller, Gary V.
    CIRCULATION-CARDIOVASCULAR IMAGING, 2012, 5 (06) : 700 - 707
  • [8] Direct Comparison of Cardiovascular Magnetic Resonance and Single-Photon Emission Computed Tomography for Detection of Coronary Artery Disease: A Meta-Analysis
    Chen, Lihua
    Wang, Xiao
    Bao, Jing
    Geng, Chengjun
    Xia, Yunbao
    Wang, Jian
    PLOS ONE, 2014, 9 (02):
  • [9] Comparative effectiveness of positron emission tomography and single-photon emission computed tomography myocardial perfusion imaging for predicting risk in patients with cardiometabolic disease
    Huck, Daniel M.
    Divakaran, Sanjay
    Weber, Brittany
    Brown, Jenifer M.
    Lopez, Diana
    Souza, Ana Carolina do A. H.
    Hainer, Jon
    Blankstein, Ron
    Dorbala, Sharmila
    Di Carli, Marcelo
    JOURNAL OF NUCLEAR CARDIOLOGY, 2024, 40
  • [10] Diagnostic performance of positron emission tomography in the detection of coronary artery disease: A meta-analysis
    Nandalur, Kiran R.
    Dwamena, Ben A.
    Choudhri, Asim F.
    Nandalur, Sirisha R.
    Reddy, Priya
    Carlos, Ruth C.
    ACADEMIC RADIOLOGY, 2008, 15 (04) : 444 - 451