Appearance of the Frequency-Doubling Stimulus at Threshold

被引:2
|
作者
Hogg, Ruth Esther [1 ]
Anderson, Andrew John [1 ]
机构
[1] Univ Melbourne, Dept Optometry & Vis Sci, Melbourne, Vic 3010, Australia
关键词
TECHNOLOGY PERIMETRY; PERIPHERAL-VISION; ILLUSION; GLAUCOMA; ADAPTATION; RESOLUTION; RESPONSES;
D O I
10.1167/iovs.08-2866
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. It has been argued that the threshold for detecting frequency-doubling (FD) technology perimeter stimuli differs from the threshold for perceiving spatial structure (pattern) in the same targets. Thresholds for perceiving spatial structure have typically been assessed using orientation-identification experiments. The authors investigated the influence of orientation, edge profile, and psychophysical method on the origin of the reported differences in detection and orientation-identification thresholds for FD gratings. METHODS. Detection and orientation-identification thresholds were determined in 12 observers with the use of FD stimuli (0.25 cyc/deg, 25 Hz) presented centrally and at 15 eccentricity. Edge profile (square- and Gaussian-windowed) and orientation (horizontal, vertical, and oblique) were independently modified. Detection thresholds were also measured for spatially uniform flickering targets (25 Hz). Orientation-identification thresholds using a two-alternative forced choice (2-AFC) and a two-interval forced choice (2-IFC) method were also compared in five experienced observers. RESULTS. Orientation-identification and detection thresholds did not significantly differ under any condition tested. Orientation-identification thresholds obtained with 2-AFC were not significantly different from those obtained with 2-IFC. Thresholds for spatially uniform flicker were significantly lower than for FD stimuli. CONCLUSIONS. The authors found that orientation-identification and detection thresholds for FD gratings did not differ and argue that recent findings to the contrary arise from the inappropriate use of spatially uniform flicker targets as alternatives in 2-IFC experiments. (Invest Ophthalmol Vis Sci. 2009; 50: 1477-1482) DOI:10.1167/iovs.08-2866
引用
收藏
页码:1477 / 1482
页数:6
相关论文
共 50 条
  • [41] SATURATION OF SELF-PREPARED FREQUENCY-DOUBLING FIBERS
    LACERDA, MM
    CARVALHO, ICS
    MARGULIS, W
    LESCHE, B
    ELECTRONICS LETTERS, 1994, 30 (09) : 732 - 733
  • [42] Frequency-doubling perimetry in patients following penetrating keratoplasty
    Nguyen, NX
    Horn, FK
    Seitz, B
    Cursiefen, C
    Küchle, M
    CORNEA, 2004, 23 (05) : 433 - 438
  • [43] FREQUENCY-DOUBLING TACH OPERATES FROM A SINGLE SUPPLY
    FREDERIKSEN, T
    EDN MAGAZINE-ELECTRICAL DESIGN NEWS, 1977, 22 (11): : 208 - 208
  • [44] Laser at 532 nm by intracavity frequency-doubling in BBO
    Xiandan Yuan
    Jinsong Wang
    Yongqi Chen
    Yulong Wu
    Yunfei Qi
    Meijiao Sun
    Qi Wang
    Journal of Semiconductors, 2017, 38 (06) : 88 - 91
  • [45] Laser-diode frequency-doubling is simple and efficient
    Hayasaka, K
    LASER FOCUS WORLD, 2004, 40 (09): : 7 - 7
  • [46] FREQUENCY-DOUBLING FROM A NOVEL ORGANIC-CRYSTAL
    SASAKI, K
    KINOSHITA, T
    HORINOUCHI, S
    YAMAKAWA, S
    TANAKA, N
    OKAMOTO, H
    INTERNATIONAL JOURNAL OF NONLINEAR OPTICAL PHYSICS, 1994, 3 (04): : 479 - 487
  • [47] PREPARATION OF FREQUENCY-DOUBLING FIBERS UNDER UV EXCITATION
    CARVALHO, ICS
    MARGULIS, W
    LESCHE, B
    OPTICS LETTERS, 1991, 16 (19) : 1487 - 1489
  • [48] Impact of cataract on the results of frequency-doubling technology perimetry
    Tanna, AP
    Abraham, C
    Lai, J
    Shen, J
    OPHTHALMOLOGY, 2004, 111 (08) : 1504 - 1507
  • [49] Synthesis, Structure, and Frequency-Doubling Effect of Calcium Cyanurate
    Kalmutzki, Markus
    Stroebele, Markus
    Wackenhut, Frank
    Meixner, Alfred J.
    Meyer, H. -Juergen
    ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2014, 53 (51) : 14260 - 14263
  • [50] Frequency-doubling perimetry in young children - Author reply
    Blumenthal, EZ
    Haddad, A
    Horani, A
    Anteby, I
    OPHTHALMOLOGY, 2005, 112 (01) : 169 - 170