Characterization of Water Sorption, Solubility, and Roughness of Silorane- and Methacrylate-based Composite Resins

被引:22
作者
Giannini, M. [1 ]
Di Francescantonio, M. [2 ]
Pacheco, R. R. [3 ]
Cidreira Boaro, L. C. [4 ]
Braga, R. R. [5 ]
机构
[1] Univ Estadual Campinas, Piracicaba Dent Sch, Dept Restorat Dent, Piracicaba, SP, Brazil
[2] Univ Estadual Campinas, Piracicaba Dent Sch, Dept Restorat Dent, Piracicaba, SP, Brazil
[3] Univ Estadual Campinas, Piracicaba Dent Sch, Dept Dent Mat, Piracicaba, SP, Brazil
[4] Univ Santo Amaro, Sch Dent, Dept Dent, Sao Paulo, Brazil
[5] Univ Sao Paulo, Dept Dent Mat, Sao Paulo, Brazil
基金
巴西圣保罗研究基金会;
关键词
STEP POLISHING SYSTEMS; SURFACE-ROUGHNESS; STAINING SUSCEPTIBILITY; MECHANICAL-PROPERTIES; DENTAL MATERIALS; POLYMERIZATION; GLOSS; TIME; STABILITY; SHRINKAGE;
D O I
10.2341/12-526-L
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: The objective of this study was to evaluate the surface roughness (SR), water sorption (WS), and solubility (SO) of four composite resins after finishing/polishing and after one year of water storage. Materials and Methods: Two low-shrinkage composites (Filtek Silorane [3M ESPE] and Aelite LS [Bisco Inc]) and two composites of conventional formulations (Heliomolar and Tetric N-Ceram [Ivoclar Vivadent]) were tested. Their respective finishing and polishing systems (Sof-Lex Discs, 3M ESPE; Finishing Discs Kit, Bisco Inc; and Astropol F, P, HP, Ivoclar Vivadent) were used according to the manufacturers' instructions. Ten disc-shaped specimens of each composite resin were made for each evaluation. Polished surfaces were analyzed using a profilometer after 24 hours and one year. For the WS and SO, the discs were stored in desiccators until constant mass was achieved. Specimens were then stored in water for seven days or one year, at which time the mass of each specimen was measured. The specimens were dried again and dried specimen mass determined. The WS and SO were calculated from these measurements. Data were analyzed by two-way analysis of variance and Tukey post hoc test (alpha=0.05). Results: Filtek Silorane showed the lowest SR, WS, and SO means. Water storage for one year increased the WS means for all composite resins tested. Conclusions: The silorane-based composite resin results were better than those obtained for methacrylate-based resins. One-year water storage did not change the SR and SO properties in any of the composite resins.
引用
收藏
页码:264 / 272
页数:9
相关论文
共 38 条
  • [1] Attar N, 2008, J CONT DENT PRACTICE, V8, P27
  • [2] Bashetty Kusum, 2010, J Conserv Dent, V13, P34, DOI 10.4103/0972-0707.62637
  • [3] Berger SB, 2011, J ESTHET RESTOR DENT, V23, P34, DOI 10.1111/j.1708-8240.2010.00376.x
  • [4] EFFECT OF DIFFERENT POLISHING SYSTEMS ON THE SURFACE ROUGHNESS OF MICROHYBRID COMPOSITES
    Brusaca Almeida Scheibe, Kristine Guara
    Brusaca Almeida, Karoline Guara
    Medeiros, Igor Studart
    Costa, Jose Ferreira
    Coelho Alves, Claudia Maria
    [J]. JOURNAL OF APPLIED ORAL SCIENCE, 2009, 17 (01) : 21 - 26
  • [5] The effect of polishing techniques and time on the surface characteristics and sealing ability of resin composite restorations after one-year storage
    Cenci, M. S.
    Venturini, D.
    Pereira-Cenci, T.
    Piva, E.
    Demarco, F. F.
    [J]. OPERATIVE DENTISTRY, 2008, 33 (02) : 169 - 176
  • [6] Changes in surface characteristics of dental resin composites after polishing
    Choi, MS
    Lee, YK
    Lim, BS
    Rhee, SH
    Yang, HC
    [J]. JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2005, 16 (04) : 347 - 353
  • [7] Volumetric dimensional change of six direct core materials
    Chutinan, S
    Platt, JA
    Cochran, MA
    Moore, BK
    [J]. DENTAL MATERIALS, 2004, 20 (04) : 345 - 351
  • [8] Stability of silorane dental monomers in aqueous systems
    Eick, J. David
    Smith, Robert E.
    Pinzino, Charles S.
    Kostoryz, Elisabet L.
    [J]. JOURNAL OF DENTISTRY, 2006, 34 (06) : 405 - 410
  • [9] Surface roughness of novel resin composites polished with one-step systems
    Erguecue, Z.
    Tuerkuen, L. S.
    [J]. OPERATIVE DENTISTRY, 2007, 32 (02) : 185 - 192
  • [10] Surface deterioration of dental materials after simulated toothbrushing in relation to brushing time and load
    Heintze, S. D.
    Forjanic, M.
    Ohmiti, K.
    Rousson, V.
    [J]. DENTAL MATERIALS, 2010, 26 (04) : 306 - 319