Evaluating the impact of measurement uncertainty in blood pressure measurement on hypertension diagnosis

被引:10
作者
Rodrigues Filho, Bruno A. [1 ]
Farias, Rafael F. [1 ]
dos Anjos, Wilian [2 ]
机构
[1] Natl Inst Metrol Qual & Technol Inmetro, Dept Legal Metrol, Sao Paulo, Brazil
[2] Weights & Measures Inst Sao Paulo IPEM SP, Dept Sci & Ind Metrol, Sao Paulo, Brazil
基金
巴西圣保罗研究基金会;
关键词
hypertension; measurement error; measurement uncertainty; sphygmomanometer; SPHYGMOMANOMETERS; ACCURACY;
D O I
10.1097/MBP.0000000000000321
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Background and objectiveThe sphygmomanometer is a well-known device used widely for blood pressure (BP)measurement in primary cares to diagnose hypertension. It is also vastly used by patients to monitor BP for medication. Deviations in measurement might affect significantly the diagnosis. For example, a hypertensive patient might be diagnosed as normal and consequently not receive proper treatment or a healthy patient might be diagnosed as hypertensive and may receive treatment for a nonexistent disease. A measurement has two components, the error and the measurement uncertainty, both affecting the interpretation of the results yielded by the sphygmomanometer. As the impact of measurement uncertainty has not been considered properly, the present study aims to evaluate how it influences the misdiagnosis of hypertension.Materials and methodsA theoretical approach is applied, using two samples from the literature, simulating how the measurement uncertainty affects the diagnosis of a sample with known BP for a sphygmomanometer indicating the threshold pressures of diagnosis. We also carried out a study evaluating how the number of measurements taken affects the probability of misdiagnosis.ResultsFor one of the samples, the results show an increase in misdiagnosis of 227% for diastolic pressure and 225% for systolic pressure, considering the threshold of 90 and 140mmHg, for a measurement error of -5mmHg when considering a 5mmHg uncertainty in comparison with when it is disregarded. The probability of a correct diagnosis also converges to over 98% for four measurements taken.ConclusionThe significant impact of misdiagnosis is an indicator of the importance of considering the uncertainties as a component to medical decision. The number of measurements taken also plays a major role in hypertension diagnosis. Copyright (c) 2018 Wolters Kluwer Health, Inc. All rights reserved.
引用
收藏
页码:141 / 147
页数:7
相关论文
共 15 条
  • [1] Type and accuracy of sphygmomanometers in primary care: a cross-sectional observational study
    A'Court, Christine
    Stevens, Richard
    Sanders, Sarah
    Ward, Alison
    McManus, Richard
    Heneghan, Carl
    [J]. BRITISH JOURNAL OF GENERAL PRACTICE, 2011, 61 (590) : e598 - e603
  • [2] Central pressures and central hemodynamic values in white coat hypertensives are closer to those of normotensives than to those of controlled hypertensives for similar age, gender, and 24-h and nocturnal blood pressures
    Almeida, Joana
    Monteiro, Jose
    Silva, Jose A.
    Bertoquini, Susana
    Polonia, Jorge
    [J]. REVISTA PORTUGUESA DE CARDIOLOGIA, 2016, 35 (11) : 559 - 567
  • [3] Calibration accuracy of hospital-based non-invasive blood pressure measuring devices
    de Greeff, A.
    Lorde, I.
    Wilton, A.
    Seed, P.
    Coleman, A. J.
    Shennan, A. H.
    [J]. JOURNAL OF HUMAN HYPERTENSION, 2010, 24 (01) : 58 - 63
  • [4] Accuracy of Sphygmanometers at Pharmacies
    Erdem, Dilek Gurgenyatagi
    Erdem, Emre
    Dilek, Melda
    Aydogdu, Turkan
    Selim, Nevzat
    Demiray, Feride
    Sari, Aysel
    Akpolat, Tekin
    [J]. KIDNEY & BLOOD PRESSURE RESEARCH, 2009, 32 (04) : 231 - 234
  • [5] Fraga CHM, 2017, MORE EFFECTIVE APPRO, VLVIII, P5
  • [6] LeWine H, 2016, NEW GUIDELINES PUBLI
  • [7] How accurate are sphygmomanometers?
    Mion, D
    Pierin, AMG
    [J]. JOURNAL OF HUMAN HYPERTENSION, 1998, 12 (04) : 245 - 248
  • [8] OIML, 2002, R 16 1 NON MECH SPHY
  • [9] OIML, 2002, R 16 2 NON AUT SPHYG
  • [10] OIML, 2012, INT VOC METR BAS GEN