Diagnostic accuracy of CBCT for tooth fractures: A meta-analysis

被引:39
作者
Long, Hu [1 ]
Zhou, Yang [1 ]
Ye, Niansong [1 ]
Liao, Lina [1 ]
Jian, Fan [1 ]
Wang, Yan [1 ]
Lai, Wenli [1 ]
机构
[1] Sichuan Univ, Dept Orthodont, State Key Lab Oral Dis, West China Hosp Stomatol, Chengdu 610041, Peoples R China
基金
中国国家自然科学基金;
关键词
Cone-beam computed tomography; Diagnostic accuracy; Meta-analysis; Root fracture; Systematic review; Tooth fracture; BEAM COMPUTED-TOMOGRAPHY; VERTICAL ROOT FRACTURES; ENDODONTICALLY TREATED TEETH; RADIOGRAPHY; MANAGEMENT; DENTITION;
D O I
10.1016/j.jdent.2013.11.024
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The objective of this meta-analysis was to determine the diagnostic accuracy of cone-beam computed tomography (CBCT) for tooth fractures in vivo. Methods: PubMed, Embase, Web of Science, ProQuest Dissertations & Theses, CNKI and SIGLE were searched from January 1990 to April 2013 for eligible studies. Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) was employed to assess the quality of the included studies. Meta-analyses were performed in MetaDisc 1.4, Stata 12.1 and StatsDirect 2.7.9. Results: Finally, 12 studies were included in this meta-analysis. The pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio and summary receiver operating characteristic were 0.92 (95% CI = 0.89-0.94), 0.85 (95% CI = 0.75-0.92), 5.68 (95% CI = 3.42-9.45), 0.13 (95% CI = 0.09-0.18) and 0.94 (95% CI = 0.90-0.98), respectively. The pooled prevalence of tooth fractures in patients with clinically-suspected but periapical-radiography-undetected tooth fractures was 91% (95% CI = 83%-97%). Positive and negative predictive values were 0.98 and 0.43 (subgroup analysis: 0.98 and 0.28 for endodontically-treated teeth; 0.99 and 0.77 for non-endodontically-treated teeth). Conclusion: We suggest that CBCT has a high diagnostic accuracy for tooth fractures and could be used in clinical settings. We can be very confident with positive test results but should be very cautious with negative test results, especially for endodontically treated teeth. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:240 / 248
页数:9
相关论文
共 47 条
  • [41] A Systematic Review and Meta-analysis of the Diagnostic Accuracy of Frozen Section for Parotid Gland Lesions
    Schmidt, Robert L.
    Hunt, Jason P.
    Hall, Brian J.
    Wilson, Andrew R.
    Layfield, Lester J.
    [J]. AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2011, 136 (05) : 729 - 738
  • [42] Procalcitonin as a diagnostic marker for sepsis: a systematic review and meta-analysis
    Wacker, Christina
    Prkno, Anna
    Brunkhorst, Frank M.
    Schlattmann, Peter
    [J]. LANCET INFECTIOUS DISEASES, 2013, 13 (05) : 426 - 435
  • [43] Properties of the summary receiver operating characteristic (SROC) curve for diagnostic test data
    Walter, SD
    [J]. STATISTICS IN MEDICINE, 2002, 21 (09) : 1237 - 1256
  • [44] Detection of dental root fractures by using cone-beam computed tomography
    Wang, P.
    Yan, X. B.
    Lui, D. G.
    Zhang, W. L.
    Zhang, Y.
    Ma, X. C.
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2011, 40 (05) : 290 - 298
  • [45] QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies
    Whiting, Penny F.
    Rutjes, Anne W. S.
    Westwood, Marie E.
    Mallett, Susan
    Deeks, Jonathan J.
    Reitsma, Johannes B.
    Leeflang, Mariska M. G.
    Sterne, Jonathan A. C.
    Bossuyt, Patrick M. M.
    [J]. ANNALS OF INTERNAL MEDICINE, 2011, 155 (08) : 529 - U104
  • [46] [闫雪冰 Yan Xuebing], 2011, [实用口腔医学杂志, Journal of Practical Stomatology], V27, P46
  • [47] Meta-DiSc: A software for meta-analysis of test accuracy data
    Zamora J.
    Abraira V.
    Muriel A.
    Khan K.
    Coomarasamy A.
    [J]. BMC Medical Research Methodology, 6 (1)