Vertically Integrated Pixel Microbolometers for IR Imaging Using High Resistivity VOx

被引:6
|
作者
Basantani, Hitesh A. [1 ]
Shin, Hang-Beum
Jackson, T. N.
Horn, Mark W. [1 ]
机构
[1] Penn State Univ, Dept Engn Sci & Mech, University Pk, PA 16802 USA
关键词
Vanadium Oxide; High TCR; microbolometer; through film; 1/f noise; Johnson noise;
D O I
10.1117/12.2016292
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Uncooled IR bolometers form an integral part of thermal imaging cameras. Vanadium oxide material currently used for IR imaging has a resistivity between 0.1 and 1 ohm-cm and a temperature coefficient of resistance (TCR) between -1.4%K-1 to -2.4%K-1. Higher TCR materials are desired, however, such materials inevitably have higher resistivity and therefore higher electrical resistance in a lateral resistor configuration. A high resistance leads to an increase in the Johnson-Nyquist noise of the bias-induced current, thereby limiting the performance of bolometers using high resistivity material. In this work, we demonstrate high resistivity, high TCR VOx and propose the use of a vertically integrated resistor configuration an alternate pixel structure design with lower Johnson noise when compared with the conventional lateral pixel design. Biased Target Ion Beam Deposition was used to deposit high resistivity vanadium oxide thin-films (similar to 85 nm thick). Electrical characterization of lateral resistor structures showed resistivities ranging from 2 x 10(3) ohm-cm to 2.1 x 10(4) ohm-cm, TCR varying from -2.6%K-1 to -5%K-1, Johnson noise (pixel resistance of 1.3G Omega) of 4.7 to 6 mu V/root Hz and 1/f noise (normalized Hooge's parameter (alpha/n)) of 5 x 10(-21) to 5 x 10(-18) cm(-3). In contrast, the through-film resistor structures showed significantly higher resistivities at 3 x 10(4) Ohm-cm to 1.55 x 10(5) Ohm-cm, TCR similar to lateral resistive structure between -2.6%K-1 to -5.1%K-1, immeasurably low Johnson noise (pixel resistance of 48K Omega) and normalized Hooge's parameter ranging from to 5 x 10(-21) to 1 x 10(-18) cm(-3). These results indicate the possible use of through-film resistors as an alternative to the conventional lateral-resistor design currently used in uncooled imaging microbolometers.
引用
收藏
页数:5
相关论文
共 50 条
  • [32] An integrated folded-patch chip-size antenna using high-resistivity polycrystalline silicon substrate
    Mendes, PM
    Polyakov, A
    Bartek, M
    Burghartz, JN
    Correia, JH
    ASDAM 2004: THE FIFTH INTERNATIONAL CONFERENCE ON ADVANCED SEMICONDUCTOR DEVICES AND MICROSYSTEMS, 2004, : 311 - 314
  • [33] Atomic force microscopy for high speed imaging using cantilevers with an integrated actuator and sensor
    Manalis, SR
    Minne, SC
    Quate, CF
    APPLIED PHYSICS LETTERS, 1996, 68 (06) : 871 - 873
  • [34] Gamma-ray imaging using a CdZnTe pixel array and a high-resolution, parallel-hole collimator
    Kastis, GA
    Barber, HB
    Barrett, HH
    Balzer, SJ
    Lu, D
    Marks, DG
    Stevenson, G
    Woolfenden, JM
    Appleby, M
    Tueller, J
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2000, 47 (06) : 1923 - 1927
  • [35] High-resolution ultrasound imaging using unified pixel-based and filtered delay multiply and sum beamforming
    Guo, Hao
    Xie, Hui-Wen
    Zhou, Guang-Quan
    Nguyen, Nghia Q.
    Prager, Richard W.
    INTERNATIONAL ULTRASONICS SYMPOSIUM (IEEE IUS 2021), 2021,
  • [36] High-dynamic-range coherent diffractive imaging: ptychography using the mixed-mode pixel array detector
    Giewekemeyer, Klaus
    Philipp, Hugh T.
    Wilke, Robin N.
    Aquila, Andrew
    Osterhoff, Markus
    Tate, Mark W.
    Shanks, Katherine S.
    Zozulya, Alexey V.
    Salditt, Tim
    Gruner, Sol M.
    Mancuso, Adrian P.
    JOURNAL OF SYNCHROTRON RADIATION, 2014, 21 : 1167 - 1174
  • [37] High definition cross-well electrical resistivity imaging using seismoelectric focusing and image-guided inversion
    Sava, P.
    Revil, A.
    Karaoulis, M.
    GEOPHYSICAL JOURNAL INTERNATIONAL, 2014, 198 (02) : 880 - 894
  • [38] High-speed IR monitoring of a turbojet engine gas flow using an uncooled MWIR imaging sensor
    Linares-Herrero, R.
    Archilla-Prat, V.
    Montojo-Supervielle, M. T.
    Gutierrez-Alvarez, R.
    Vergara, G.
    Baldasano-Ramirez, A.
    Mercader, Daniel
    Jimenez, Ana
    THERMOSENSE: THERMAL INFRARED APPLICATIONS XXXIII, 2011, 8013
  • [39] Label-Free Biomedical Imaging Using High-Speed Lock-In Pixel Sensor for Stimulated Raman Scattering
    Mars, Kamel
    Lioe, De Xing
    Kawahito, Shoji
    Yasutomi, Keita
    Kagawa, Keiichiro
    Yamada, Takahiro
    Hashimoto, Mamoru
    SENSORS, 2017, 17 (11):
  • [40] Gamma-ray imaging using a CdZnTe pixel array and a high-resolution, parallel-hole collimator.
    Kastis, GA
    Barber, HB
    Barrett, HH
    Balzer, SJ
    Lu, D
    Marks, DG
    Stevenson, G
    Woolfenden, JM
    Appleby, M
    Tueller, J
    1999 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1999, : 553 - 558