Detection of simulated interstitial lung disease and catheters with selenium, storage phosphor, and film-based radiography

被引:34
作者
Bernhardt, TM
Otto, D
Reichel, G
Ludwig, K
Seifert, S
Kropf, S
Rapp-Bernhardt, U
机构
[1] Otto von Guericke Univ, Dept Diagnost Radiol, D-39120 Magdeburg, Germany
[2] Otto von Guericke Univ, Dept Biometr & Med Informat, D-39120 Magdeburg, Germany
关键词
lung; radiography; phantoms; comparative studies; digital; selenium detector; storage phosphor; receiver operating characteristic (ROC) curve;
D O I
10.1148/radiology.213.2.r99nv20445
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate the diagnostic performance of storage phosphor and digital selenium radiography (DSR) with asymmetric and symmetric screen-film systems at different, speeds in the detection of simulated interstitial lung disease and catheters. MATERIALS AND METHODS: Patterns of simulated interstitial lung disease and catheters were superimposed over an anthropomorphic chest phantom. Hard-copy images were generated at DSR (200-, 400-, and 600-speed), storage phosphor radiography (200- and 400-speed), and asymmetric (400-speed) and symmetric (200- and 400-speed) screen-film imaging. Surface doses were measured, and receiver operating characteristic analyses were performed. RESULTS: No statistically significant differences were found between the detector systems with the same speeds for each interstitial pattern. Significantly poorer results were found at 600-speed DSR than at 200-speed DSR. Detection of catheters and nodules over high-attenuation areas was significantly worse with the symmetric screen-film system than with the other detectors. The surface dose with the DSR system, without a grid, was about 50% less than that of the other detector systems, with grids, tit the same speed. CONCLUSION: No significant difference was found in the diagnostic performance at DSR, storage phosphor radiography, and film-based radiography for simulated interstitial lung disease at corresponding speeds; there was a reduction in the surface dose of about 50% with the 400-speed DSR system.
引用
收藏
页码:445 / 454
页数:10
相关论文
共 22 条
  • [1] TECHNICAL EVALUATION OF A DIGITAL CHEST RADIOGRAPHY SYSTEM THAT USES A SELENIUM DETECTOR
    CHOTAS, HG
    FLOYD, CE
    RAVIN, CE
    [J]. RADIOLOGY, 1995, 195 (01) : 264 - 270
  • [2] DENCKER E, 1997, ROFO S, V166, P82
  • [3] SELENIUM-BASED DIGITAL RADIOGRAPHY OF THE CHEST - RADIOLOGISTS PREFERENCE COMPARED WITH FILM-SCREEN RADIOGRAPHS
    FLOYD, CE
    BAKER, JA
    CHOTAS, HG
    DELONG, DM
    RAVIN, CE
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (06) : 1353 - 1358
  • [4] Digital thoracic radiography using a selenium detector: Prospective comparison with conventional radiography
    Freund, M
    Reuter, M
    Palmie, S
    Harder, E
    Hutzelmann, A
    Heller, M
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1997, 166 (02): : 101 - 107
  • [5] DETECTION OF CENTRAL VENOUS CATHETERS WHEN USING STORAGE PHOSPHOR RADIOGRAPHY IN INTENSIVE-CARE RADIOLOGY
    GALANSKI, M
    PROKOP, M
    THORNS, E
    OESTMANN, JW
    REICHELT, S
    HAUBITZ, B
    MILBRADT, H
    GRASER, A
    VERNER, L
    SCHAEFER, C
    [J]. FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1992, 156 (01): : 68 - 72
  • [6] VALUE OF THE ASYMMETRIC FILM-SCREEN SYSTEM INSIGHT HC IN CHEST IMAGING
    HAUSSLER, MD
    LENZEN, H
    RECKELS, C
    PETERS, PE
    [J]. FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1994, 160 (03): : 266 - 270
  • [7] DIGITAL CHEST IMAGING WITH A SELENIUM DETECTOR - COMPARISON WITH CONVENTIONAL RADIOGRAPHY FOR VISUALIZATION OF SPECIFIC ANATOMIC REGIONS OF THE CHEST
    HEESEWIJK, HPM
    NEITZEL, U
    VANDERGRAAF, Y
    DEVALOIS, JC
    FELDBERG, MAM
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (03) : 535 - 540
  • [8] Kehler M, 1996, ACTA RADIOL, V37, P332
  • [9] KEHLER M, 1991, ACTA RADIOL, V32, P18
  • [10] INTERPRETATION OF SUBTLE INTERSTITIAL LUNG ABNORMALITIES - CONVENTIONAL VERSUS FILM-DIGITIZED RADIOGRAPHY
    KIDO, S
    IKEZOE, J
    TAKEUCHI, N
    KONDOH, H
    JOHKOH, T
    KOHNO, N
    TOMIYAMA, N
    YAMAGAMI, H
    NAITO, H
    ARISAWA, J
    KOZUKA, T
    [J]. RADIOLOGY, 1994, 192 (01) : 171 - 176