Development of a method for metabolomic analysis of human exhaled breath condensate by gas chromatography-mass spectrometry in high resolution mode

被引:31
|
作者
Peralbo-Molina, A. [1 ,2 ]
Calderon-Santiago, M. [1 ,2 ]
Priego-Capote, F. [1 ,2 ]
Jurado-Gamez, B. [2 ]
Luque de Castro, M. D. [1 ,2 ]
机构
[1] Univ Cordoba, Dept Analyt Chem, E-14071 Cordoba, Spain
[2] Univ Cordoba, Reina Sofia Hosp, Inst Biomed Res Maimonides IMIBIC, E-14071 Cordoba, Spain
关键词
Metabolomics; Profiling; Exhaled breath condensate; Gas chromatography; Exhaled breath condensate metabolome; Mass spectrometry; VOLATILE ORGANIC-COMPOUNDS; LUNG-CANCER; CLINICAL-DIAGNOSIS; BIOMARKERS; AIR; COPD;
D O I
10.1016/j.aca.2015.07.008
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Exhaled breath condensate (EBC) is a promising biofluid scarcely used in clinical analysis despite its non-invasive sampling. The main limitation in the analysis of EBC is the lack of standardized protocols to support validation studies. The aim of the present study was to develop an analytical method for analysis of human EBC by GCeTOF/MS in high resolution mode. Thus, sample preparation strategies as liquid-liquid extraction and solid-phase extraction were compared in terms of extraction coverage. Liquid-liquid extraction resulted to be the most suited sample preparation approach providing an average extraction efficiency of 77% for all compounds in a single extraction. Different normalization approaches were also compared to determine which strategy could be successfully used to obtain a normalized profile with the least variability among replicates of the same sample. Normalization to the total useful mass spectrometry signal (MSTUS) proved to be the most suited strategy for the analysis of EBC from healthy individuals (n = 50) reporting a within-day variability below 7% for the 51 identified compounds and a suited data distribution in terms of percentage of metabolites passing the Skewness and Kurtosis test for normality distribution. The composition of EBC was clearly dominated by the presence of fatty acids and derivatives such as methyl esters and amides, and volatile prenol lipids. Therefore, EBC offers the profile of both volatile and non-volatile components as compared to other similar biofluids such as exhaled breath vapor, which only provides the volatile profile. This human biofluid could be an alternative to others such as serum/plasma, urine or sputum to find potential markers with high value for subsequent development of screening models. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:118 / 126
页数:9
相关论文
共 50 条
  • [21] Processing optimization of exhaled breath condensate previous to the analysis by mass spectrometry
    Nunez-Naveira, Laura
    Marinas-Pardo, Luis
    Lema-Costa, Beatriz
    Flores-Calle, Ninoska
    Verea-Hernando, Hector
    Montero-Martinez, Carmen
    EUROPEAN RESPIRATORY JOURNAL, 2012, 40
  • [22] PROTEOMIC ANALYSIS OF EXHALED BREATH CONDENSATE SAMPLES: HIGH REPRODUCIBILITY OF MASS SPECTROMETRIC MEASUREMENTS
    Vaclavkova, Jana
    Kourilova, Pavla
    Vrbkova, Jana
    Holub, Dusan
    Hajduch, Marian
    Dzubak, Petr
    CHEMICKE LISTY, 2020, 114 (07): : 470 - 479
  • [23] Lyophilization with Subsequent Derivatization vs Microextraction by Packed Sorbent (MEPS) in the Analysis of Exhaled Breath Condensate by Gas Chromatography–Mass Spectrometry
    A. I. Revelsky
    A. S. Kozyr’
    A. S. Samokhin
    E. Kh. Anaev
    I. A. Revelsky
    Journal of Analytical Chemistry, 2022, 77 : 1294 - 1299
  • [24] Modelling electronic nose sensor deflections by matching Gas Chromatography-Mass Spectrometry exhaled breath samples
    Brinkman, Paul
    Sinha, Anirban
    Lammers, Ariane
    Van Bragt, Job J. M. H.
    Richards, Levi B.
    Dagelet, Yennece W. F.
    Ibrahim, Mahmoud I. A.
    Neerincx, Anne H.
    Bos, Lieuwe D.
    Sterk, Peter J.
    Maitland-Van der Zee, Anke-Hilse
    EUROPEAN RESPIRATORY JOURNAL, 2019, 54
  • [25] The determination of polycyclic aromatic hydrocarbons in human urine by high-resolution gas chromatography-mass spectrometry
    Cho, Sung-Hee
    Lee, Sun-Kyung
    Kim, Chong Hyeak
    BIOMEDICAL CHROMATOGRAPHY, 2018, 32 (05)
  • [26] Selective quantification of free 3-nitrotyrosine in exhaled breath condensate in asthma using gas chromatography/tandem mass spectrometry
    Lärstad, M
    Söderling, AS
    Caidahl, K
    Olin, AC
    NITRIC OXIDE-BIOLOGY AND CHEMISTRY, 2005, 13 (02): : 134 - 144
  • [27] Enhanced gas chromatography-mass spectrometry method for bacterial polyhydroxyalkanoates analysis
    Tan, Giin-Yu Amy
    Chen, Chia-Lung
    Ge, Liya
    Li, Ling
    Wang, Lin
    Zhao, Lei
    Mo, Yu
    Tan, Swee Ngin
    Wang, Jing-Yuan
    JOURNAL OF BIOSCIENCE AND BIOENGINEERING, 2014, 117 (03) : 379 - 382
  • [28] Quantifying exhaled acetone and isoprene through solid phase microextraction and gas chromatography-mass spectrometry
    Schulz, Eray
    Woollam, Mark
    Vashistha, Sneha
    Agarwal, Mangilal
    ANALYTICA CHIMICA ACTA, 2024, 1301
  • [29] Exhaled breath condensate analysis from intubated newborns by nano-HPLC coupled to high resolution MS
    Kononikhin, A. S.
    Starodubtseva, N. L.
    Chagovets, V. V.
    Ryndin, A. Y.
    Burov, A. A.
    Popov, I. A.
    Bugrova, A. E.
    Dautov, R. A.
    Tokareva, A. O.
    Podurovskaya, Y. L.
    Ionov, O. V.
    Frankevich, V. E.
    Nikolaev, E. N.
    Sukhikh, G. T.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2017, 1047 : 97 - 105
  • [30] Breath analysis using electronic nose and gas chromatography-mass spectrometry: A pilot study on bronchial infections in bronchiectasis
    Fontes de Oliveira, Luciana
    Mallafre-Muro, Celia
    Giner, Jordi
    Perea, Lidia
    Sibila, Oriol
    Pardo, Antonio
    Marco, Santiago
    CLINICA CHIMICA ACTA, 2022, 526 : 6 - 13