Control of Variable Speed Wind Turbines with Doubly Fed Asynchronous Generators for Stand-Alone Applications

被引:21
作者
Arnaltes, Santiago [1 ]
Luis Rodriguez-Amenedo, Jose [1 ]
Montilla-DJesus, Miguel E. [1 ]
机构
[1] Carlos III Univ Madrid, Dept Elect Engn, Ave Univ 30, Madrid 28911, Spain
来源
ENERGIES | 2018年 / 11卷 / 01期
关键词
Doubly-fed induction generator (DFIG); wind turbine; power control; frequency control; POWER-SYSTEM; VOLTAGE; DFIG; CONVERTERS;
D O I
10.3390/en11010026
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper addresses the design and implementation of a novel control of a variable speed wind turbine with doubly fed induction generator for stand-alone applications. In opposition to grid-tied applications, in stand-alone systems the voltage and frequency must be generated by the doubly fed induction generator. Therefore, a voltage and frequency controller is required for supplying the load at constant voltage and frequency. This controller is implemented by orientation of the generator stator flux vector along a synchronous reference axis. In this way, constant voltage and frequency is obtained and the generator will supply the active and reactive power demanded by the load, while the wind turbine will be responsible for achieving power balance in the system. Then, power control is assumed by the pitch actuator controlling the rotational speed of the wind turbine for power balancing. A load shedding mechanism is needed if the load power exceeds the maximum available wind power. Detailed simulation results are presented and discussed to demonstrate the capabilities and contributions of the proposed control scheme.
引用
收藏
页数:16
相关论文
共 24 条
  • [1] Abad G., 2011, DOUBLY FED INDUCTION, V85
  • [2] Terminal voltage build-up and control of a DFIG based stand-alone wind energy conversion system
    Abdoune, Fateh
    Aouzellag, Djamal
    Ghedamsi, Kaci
    [J]. RENEWABLE ENERGY, 2016, 97 : 468 - 480
  • [3] Ackermann T, 2005, WIND POWER IN POWER SYSTEMS, P479, DOI 10.1002/0470012684.ch22
  • [4] Variable-speed wind turbines with doubly-fed induction generators. Part I: Modelling in dynamic simulation tools
    Akhmatov, Vladislav
    [J]. 2002, Multi-Science Publishing Co. Ltd (26)
  • [5] Direct Voltage Control With Slip Angle Estimation to Extend the Range of Supported Asymmetric Loads for Stand-Alone DFIG
    Ataji, Ahmad Bashar
    Miura, Yushi
    Ise, Toshifumi
    Tanaka, Hiroki
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2016, 31 (02) : 1015 - 1025
  • [6] MRAS observer for sensorless control of standalone doubly fed induction generators
    Cárdenas, R
    Peña, R
    Proboste, J
    Asher, G
    Clare, J
    [J]. IEEE TRANSACTIONS ON ENERGY CONVERSION, 2005, 20 (04) : 710 - 718
  • [7] Enhanced Voltage Drop Control by VSC-HVDC Systems for Improving Wind Farm Fault Ridethrough Capability
    Erlich, I.
    Feltes, Ch
    Shewarega, F.
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2014, 29 (01) : 378 - 385
  • [8] Huang JY, 2008, RENEW SUST ENERG REV, V12, P2472, DOI 10.1016/j.rser.2007.06.004
  • [9] Autonomous power system for island or grid-connected wind turbines in distributed generation
    Iwanski, Grzegorz
    Koczara, Wlodzimierz
    [J]. EUROPEAN TRANSACTIONS ON ELECTRICAL POWER, 2008, 18 (07): : 658 - 673
  • [10] Control of variable speed wind turbines in islanded mode of operation
    Kanellos, F. D.
    Hatziargyriou, N. D.
    [J]. IEEE TRANSACTIONS ON ENERGY CONVERSION, 2008, 23 (02) : 535 - 543