Accuracy of plasma sTREM-1 for sepsis diagnosis in systemic inflammatory patients: a systematic review and meta-analysis

被引:81
|
作者
Wu, Youping [1 ]
Wang, Fei [1 ]
Fan, Xiaohua [1 ]
Bao, Rui [1 ]
Bo, Lulong [1 ]
Li, Jinbao [1 ]
Deng, Xiaoming [1 ]
机构
[1] Second Mil Med Univ, Changhai Hosp, Dept Anesthesiol & Intens Care, Shanghai 200433, Peoples R China
来源
CRITICAL CARE | 2012年 / 16卷 / 06期
关键词
SOLUBLE TRIGGERING RECEPTOR; C-REACTIVE PROTEIN; MYELOID CELLS-1; RESPONSE SYNDROME; NONINFECTIOUS INFLAMMATION; PROSPECTIVE COHORT; SEPTIC SHOCK; TREM-1; EXPRESSION; PROCALCITONIN;
D O I
10.1186/cc11884
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction: Early diagnosis of sepsis is vital to the clinical course and outcome of septic patients. Recently, soluble triggering receptor expressed on myeloid cells-1 (sTREM-1) appears to be a potential marker of infection. The objective of this systematic review and meta-analysis was to evaluate the accuracy of plasma sTREM-1 for sepsis diagnosis in systemic inflammatory patients. Methods: A systematic literature search of PubMed, Embase and Cochrane Central Register of Controlled Trials was performed using specific search terms (up to 15 October 2012). Studies were included if they assessed the accuracy of plasma sTREM-1 for sepsis diagnosis in adult patients with systemic inflammatory response syndrome (SIRS) and provided sufficient information to construct a 2 X 2 contingency table. Results: Eleven studies with a total of 1,795 patients were included. The pooled sensitivity and specificity was 79% (95% confidence interval (CI), 65 to 89) and 80% (95% CI, 69 to 88), respectively. The positive likelihood ratio, negative likelihood ratio and diagnostic odds ratio were 4.0 (95% CI, 2.4 to 6.9), 0.26 (95% CI, 0.14 to 0.48), and 16 (95% CI, 5 to 46), respectively. The area under the curve of the summary receiver operator characteristic was 0.87 (95% CI, 0.84 to 0.89). Meta-regression analysis suggested that patient sample size and assay method were the main sources of heterogeneity. Publication bias was suggested by an asymmetrical funnel plot (P = 0.02). Conclusions: The present meta-analysis showed that plasma sTREM-1 had a moderate diagnostic performance in differentiating sepsis from SIRS. Accordingly, plasma sTREM-1 as a single marker was not sufficient for sepsis diagnosis in systemic inflammatory patients.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Accuracy of Presepsin in Sepsis Diagnosis: A Systematic Review and Meta-Analysis
    Wu, Jiayuan
    Hu, Liren
    Zhang, Gaohua
    Wu, Fenping
    He, Taiping
    PLOS ONE, 2015, 10 (07):
  • [2] Diagnostic and prognostic predictive values of circulating sTREM-1 in sepsis: A meta-analysis
    Qin, Qin
    Liang, Lianjing
    Xia, Yiqin
    INFECTION GENETICS AND EVOLUTION, 2021, 96
  • [3] Role of sTREM-1 in predicting mortality of infection: a systematic review and meta-analysis
    Su, Longxiang
    Liu, Dan
    Chai, Wenzhao
    Liu, Dawei
    Long, Yun
    BMJ OPEN, 2016, 6 (05):
  • [4] Biomarkers for diagnosis of sepsis in patients with systemic inflammatory response syndrome: a systematic review and meta-analysis
    Liu, Yong
    Hou, Jun-huan
    Li, Qing
    Chen, Kui-jun
    Wang, Shu-Nan
    Wang, Jian-min
    SPRINGERPLUS, 2016, 5
  • [5] Accuracy of circulating microRNAs in diagnosis of sepsis: a systematic review and meta-analysis
    Shen, Xiaomin
    Zhang, Jiajie
    Huang, Yicheng
    Tong, Jiepeng
    Zhang, Li
    Zhang, Zhijuan
    Yu, Wei
    Qiu, Yunqing
    JOURNAL OF INTENSIVE CARE, 2020, 8 (01)
  • [6] Accuracy of serum procalcitonin for the diagnosis of sepsis in neonates and children with systemic inflammatory syndrome: a meta-analysis
    Pontrelli, Giuseppe
    De Crescenzo, Franco
    Buzzetti, Roberto
    Jenkner, Alessandro
    Balduzzi, Sara
    Carducci, Francesca Calo
    Amodio, Donato
    De Luca, Maia
    Chiurchiu, Sara
    Davies, Elin Haf
    Copponi, Giorgia
    Simonetti, Alessandra
    Ferretti, Elena
    Di Franco, Valeria
    Rasi, Virginia
    Della Corte, Martina
    Gramatica, Luca
    Ciabattini, Marco
    Livadiotti, Susanna
    Rossi, Paolo
    BMC INFECTIOUS DISEASES, 2017, 17
  • [7] Diagnostic value of serum soluble triggering expressed receptor on myeloid cells 1 (sTREM-1) in suspected sepsis: a meta-analysis
    Chang, Wei
    Peng, Fei
    Meng, Shan-Shan
    Xu, Jing-Yuan
    Yang, Yi
    BMC IMMUNOLOGY, 2020, 21 (01)
  • [8] Accuracy of presepsin in neonatal sepsis: systematic review and meta-analysis
    Parri, Niccolo
    Trippella, Giulia
    Lisi, Catiuscia
    De Martino, Maurizio
    Galli, Luisa
    Chiappini, Elena
    EXPERT REVIEW OF ANTI-INFECTIVE THERAPY, 2019, 17 (04) : 223 - 232
  • [9] The accuracy of presepsin for the diagnosis of sepsis from SIRS: a systematic review and meta-analysis
    Zheng, Zhongjun
    Jiang, Libing
    Ye, Ligang
    Gao, Yuzhi
    Tang, Luping
    Zhang, Mao
    ANNALS OF INTENSIVE CARE, 2015, 5 : 1 - 13
  • [10] Diagnostic accuracy of sTREM-1 to identify infection in critically ill patients with systemic inflammatory response syndrome
    Latour-Perez, Jaime
    Alcala-Lopez, Adoracion
    Garcia-Garcia, Miguel-Angel
    Sanchez-Hernandez, Jose F.
    Abad-Terrado, Carmen
    Viedma-Contreras, Jose A.
    Masia, Mar
    Gonzalez-Tejera, Matilde
    Arizo-Leon, David
    Broch Porcar, Maria-Jesus
    Bonilla-Rovira, Fernando
    Gutierrez, Felix
    CLINICAL BIOCHEMISTRY, 2010, 43 (09) : 720 - 724