Effect of cannula position in the thoracic aorta with continuous left ventricular support: four-dimensional flow-sensitive magnetic resonance imaging in an in vitro model

被引:21
作者
Benk, Christoph [1 ]
Mauch, Alexander [1 ]
Beyersdorf, Friedhelm [1 ]
Klemm, Rolf [1 ]
Russe, Maximilian [2 ]
Blanke, Philipp [2 ]
Korvink, Jan G. [3 ,4 ]
Markl, Michael [5 ,6 ]
Jung, Bernd [7 ]
机构
[1] Univ Freiburg, Dept Cardiovasc Surg, Ctr Heart, D-79106 Freiburg, Germany
[2] Univ Hosp, Dept Radiol, Freiburg, Germany
[3] Univ Freiburg, IMTEK Dept Microsyst Engn, Lab Simulat, D-79106 Freiburg, Germany
[4] Univ Freiburg, FRIAS Freiburg Inst Adv Studies, D-79106 Freiburg, Germany
[5] Northwestern Univ, Dept Radiol, Feinberg Sch Med, Chicago, IL 60611 USA
[6] Northwestern Univ, Dept Biomed Engn, McCormick Sch Engn, Chicago, IL 60611 USA
[7] Univ Hosp, Dept Radiol, Freiburg, Germany
关键词
LVAD; Three-dimensional flow characteristics; Aortic flow dynamics; LVAD outflow graft; ASSIST DEVICE; IMPLANTATION; INSUFFICIENCY; PULSATILE; LOCATION; HEART;
D O I
10.1093/ejcts/ezt095
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Left ventricular assist devices (LVADs) have become an important treatment option for heart failure patients. However, altered blood flow patterns are suspected to affect perfusion in the aorta or cause structural changes to the aortic root, leading to regurgitation and valve dysfunction or thrombus formation. The purpose of this study was to evaluate flow patterns in a realistic in vitro model system using four-dimensional flow-sensitive magnetic resonance imaging. A magnetic resonance compatible model system was developed consisting of an aorta connected to a VAD simulating the pulsatile flow of the native heart. An LVAD was connected to the aorta model via three different cannula positions. Flow patterns in the entire system as well as flow rates in predefined positions for reduced and zero cardiac output were evaluated. Cannula position influences flow patterns and flow rates in the entire thoracic aorta. For a residual cardiac output, a larger anastomosis and a decreased flow rate of the LAVD result in a higher flow rate and smaller retrograde flow in the ascending aorta when compared with a smaller anastomosis or a cannula position in the descending aorta. Pronounced flow turbulences in the aorta were observed for the cannula position in the descending aorta. In the setting of reduced cardiac output, as commonly observed in patients on LVAD therapy, a large anastomosis to the ascending aorta for the outflow cannula induces the least-adverse flow patterns in the aortic root. Our approach may aid in a better understanding of LVAD-induced flow-pattern changes. Optimization of the cannula position and anastomosis may help to prevent the progression of aortic valve-regurgitation and thrombus formation.
引用
收藏
页码:551 / 558
页数:8
相关论文
共 25 条
[1]   Three-dimensional flow characteristics in ventricular assist devices: Impact of valve design and operating conditions [J].
Benk, Christoph ;
Lorenz, Ramona ;
Beyersdorf, Friedhelm ;
Bock, Jelena ;
Klemm, Rolf ;
Korvink, Jan G. ;
Markl, Michael .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2011, 142 (05) :1019-1026
[2]  
Bock J., 2007, Proceeding of International Society for Magnetic Resonance in Medicine, P3138
[3]   3D MR flow analysis in realistic rapid-prototyping model systems of the thoracic aorta:: Comparison with in vivo data and computational fluid dynamics in identical vessel geometries [J].
Canstein, C. ;
Cachot, P. ;
Faust, A. ;
Stalder, A. F. ;
Bock, J. ;
Frydrychowicz, A. ;
Kueffer, J. ;
Hennig, J. ;
Markl, M. .
MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (03) :535-546
[4]   The Development of Aortic Insufficiency in Left Ventricular Assist Device-Supported Patients [J].
Cowger, Jennifer ;
Pagani, Francis D. ;
Haft, Jonathan W. ;
Romano, Matthew A. ;
Aaronson, Keith D. ;
Kolias, Theodore J. .
CIRCULATION-HEART FAILURE, 2010, 3 (06) :668-674
[5]   In vitro characterization of aortic retrograde and antegrade flow from pulsatile and non-pulsatile ventricular assist devices [J].
DiGiorgi, PL ;
Smith, DL ;
Naka, Y ;
Oz, MC .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2004, 23 (02) :186-192
[6]   Rise of the Machines - Left Ventricular Assist Devices as Permanent Therapy for Advanced Heart Failure [J].
Fang, James C. .
NEW ENGLAND JOURNAL OF MEDICINE, 2009, 361 (23) :2282-2285
[7]   Numerical Simulation of the Flow Field Within the Aortic Arch During Cardiac Assist [J].
Filipovic, Nenad ;
Schima, Heinrich .
ARTIFICIAL ORGANS, 2011, 35 (04) :E73-E83
[8]  
Freed BH, 2011, J INVASIVE CARDIOL, V23, P63
[9]   Less Frequent Opening of the Aortic Valve and a Continuous Flow Pump Are Risk Factors for Postoperative Onset of Aortic Insufficiency in Patients With a Left Ventricular Assist Device [J].
Hatano, Masaru ;
Kinugawa, Koichiro ;
Shiga, Taro ;
Kato, Naoko ;
Endo, Miyoko ;
Hisagi, Motoyuki ;
Nishimura, Takashi ;
Yao, Atsushi ;
Hirata, Yasunobu ;
Kyo, Shunei ;
Ono, Minoru ;
Nagai, Ryozo .
CIRCULATION JOURNAL, 2011, 75 (05) :1147-1155
[10]   Comparison of hemodynamics of intracranial aneurysms between MR fluid dynamics using 3D cine phase-contrast MRI and MR-based computational fluid dynamics [J].
Isoda, Haruo ;
Ohkura, Yasuhide ;
Kosugi, Takashi ;
Hirano, Masaya ;
Alley, Marcus T. ;
Bammer, Roland ;
Pelc, Norbert J. ;
Namba, Hiroki ;
Sakahara, Harumi .
NEURORADIOLOGY, 2010, 52 (10) :913-920