Optimization of the SPME parameters and its online coupling with HPLC for the analysis of tricyclic antidepressants in plasma samples

被引:40
作者
Alves, Claudete
Fernandes, Christian
Santos-Neto, Alvaro Jose
Rodrigues, Jose Carlos
Costa Queiroz, Maria Eugenia
Lancas, Fernando Mauro
机构
[1] Univ Sao Paulo, Inst Quim Sao Carlos, BR-13566590 Sao Carlos, SP, Brazil
[2] Univ Sao Paulo, Fac Filosofia Ciencias & Letras Ribeirao Pret, Dept Quim, BR-14049 Ribeirao Preto, Brazil
关键词
D O I
10.1093/chromsci/44.6.340
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Solid-phase microextraction (SPME)-liquid chromatography (LC) is used to analyze tricyclic antidepressant drugs desipramine, imipramine, nortriptyline, amitriptyline, and clomipramine (internal standard) in plasma samples. Extraction conditions are optimized using a 23 factorial design plus a central point to evaluate the influence of the time, temperature, and matrix pH. A Polydimethylsiloxane-divinylbenzene (60-μm film thickness) fiber is selected after the assessment of different types of coating. The chromatographic separation is realized using a C18 column (150 x 4.6 mm, 5-μm particles), ammonium acetate buffer (0.05 mol/L, pH 5.50)-acetonitrile (55:45 v/v) with 0.1% of triethylamine as mobile phase and UV-vis detection at 214 nm. Among the factorial design conditions evaluated, the best results are obtained at a pH 11.0, temperature of 30°C, and extraction time of 45 min. The proposed method, using a lab-made SPME-LC interface, allowed the determination of tricyclic antidepressants in in plasma at therapeutic concentration levels.
引用
收藏
页码:340 / 346
页数:7
相关论文
共 35 条
  • [1] Response surface methodology for the optimisation of flow-injection analysis with in situ solvent extraction and fluorimetric assay of tricyclic antidepressants
    Acedo-Valenzuela, MI
    Galeano-Díaz, T
    Mora-Díez, N
    Silva-Rodríguez, A
    [J]. TALANTA, 2005, 66 (04) : 952 - 960
  • [2] [Anonymous], STAT EXPT
  • [3] [Anonymous], 2001, GUID IND BIOAN METH
  • [4] Sensitive and rapid method for the simultaneous quantification of five antidepressants with their respective metabolites in plasma using high-performance liquid chromatography with diode-array detection
    Aymard, G
    Livi, P
    Pham, YT
    Diquet, B
    [J]. JOURNAL OF CHROMATOGRAPHY B, 1997, 700 (1-2): : 183 - 189
  • [5] Solid-phase extraction with liquid chromatography and ultraviolet detection for the assay of antidepressant drugs in human plasma
    Bakkali, A
    Corta, E
    Ciria, JI
    Berrueta, LA
    Gallo, B
    Vicente, F
    [J]. TALANTA, 1999, 49 (04) : 773 - 783
  • [6] Box GEP., 1987, EMPIRICAL MODEL BUIL, P1
  • [7] Validation of non-aqueous capillary electrophoresis for simultaneous determination of four tricyclic antidepressants in pharmaceutical formulations and plasma samples
    Cantú, MD
    Hillebrand, S
    Queiroz, MEC
    Lanças, FM
    Carrilho, E
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 799 (01): : 127 - 132
  • [8] Solid-phase microextraction coupled with high-performance liquid chromatography for the analysis of heterocyclic aromatic amines
    Cárdenes, L
    Ayala, JH
    Afonso, AM
    González, V
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2004, 1030 (1-2) : 87 - 93
  • [9] Simultaneous determination of imipramine, desipramine and their 2- and 10-hydroxylated metabolites in human plasma and urine by high-performance liquid chromatography
    Chen, AG
    Wing, YK
    Chiu, H
    Lee, S
    Chen, CN
    Chan, K
    [J]. JOURNAL OF CHROMATOGRAPHY B, 1997, 693 (01): : 153 - 158
  • [10] Solid phase microextraction with liquid chromatography-electrospray ionization-tandem mass spectrometry for analysis of amphetamine and methamphetamine in serum
    Chou, CC
    Lee, MR
    [J]. ANALYTICA CHIMICA ACTA, 2005, 538 (1-2) : 49 - 56