Volume flow rate of common carotid artery measured by Doppler method and Color Velocity Imaging Quantification (CVI-Q)

被引:20
作者
Likittanasombut, P
Reynolds, P
Meads, D
Tegeler, C
机构
[1] Wake Forest Univ, Bowman Gray Sch Med, Dept Neurol, Winston Salem, NC 27157 USA
[2] Thammasat Univ, Fac Med, Dept Med, Dept Neurol, Pathum Thani, Thailand
关键词
ultrasound; volume flow rate; catatid stenosis;
D O I
10.1177/1051228405001523
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background. Common carotid artery (CCA) volume flow rate (VFR) is clinically useful for study of cerebrovascular disease. Color Velocity Imaging Quantification (CVI-Q; Philips Ultrasound International, Irvine, CA), previously reported as accurate and reliable, tracks the flow lumen over the cardiac cycle, as well as mean spatial velocity, which is multiplied by vessel area to obtain VFR. VFR can also be obtained by Doppler sampling for mean velocity, and vessel area based on static B-mode lumen diameter. We compared CCA VFR by CVI-Q and Doppler method (DM), since knowledge of how they compare is crucial when both are used clinically. Method. We prospectively studied patients having clinical carotid duplex exams and healthy controls. All had CCA VFR measured by both methods in the same exam session. Results. Thirty-four studies were reviewed. CCA VFR by CVI-Q in those without]CA stenosis was 337 96 mL/m, and by DM 359 +/- 130 mL/m; P =.33. There was no difference between methods for 50-75% or 75-95% ICA stenosis. In 7 patients with ICA occlusion, and 3 with 95-99% stenosis, VFR was higher by DM than by CVI-Q (Occlusion: 125 vs 58 mL/m, P =.007; 95-99%:152 vs 63 mL/m, P =.038). There was no statistically significant difference between methods for measurement of the ratio of VFR between right and left CCA. Conclusion. In patients with 0-95% ICA stenosis, VFR by CVI-Q and DM showed no difference. For 95-100% ICA stenosis the methods differ; with higher VFR by DM. Side-to-side VFR ratios remain constant, irrespective of VFR method, and can still provide clinically useful information.
引用
收藏
页码:34 / 38
页数:5
相关论文
共 7 条
  • [1] Eicke B M, 1993, J Neuroimaging, V3, P89
  • [2] ULTRASONIC QUANTITATIVE FLOW VOLUMETRY OF THE CAROTID ARTERIES - INITIAL EXPERIENCE WITH A COLOR-FLOW M-MODE SYSTEM
    EICKE, BM
    TEGELER, CH
    [J]. CEREBROVASCULAR DISEASES, 1995, 5 (02) : 145 - 149
  • [3] Eicke BM, 1996, NEUROSONOLOGY, P101
  • [4] CAROTID HIGH-LOW FLOW RATIO MOST ACCURATELY PREDICTS SIGNIFICANT STENOSIS
    MEYD, CJ
    ABUSHAKRA, S
    BLEECKER, ML
    [J]. ARCHIVES OF NEUROLOGY, 1992, 49 (08) : 864 - 869
  • [5] Extracranial internal carotid artery occlusion: The role of common carotid artery volume flow
    Tan, TY
    Schminke, U
    Lien, LM
    Eicke, BM
    Tegeler, CH
    [J]. JOURNAL OF NEUROIMAGING, 2002, 12 (02) : 144 - 147
  • [6] Tegeler CH, 1999, CEREBROVASCULAR DISO, P83
  • [7] WESTKOFF HP, 1993, J ULTRAS MED, V12, pS2