Image quality in low-dose coronary computed tomography angiography with a new high-definition CT scanner

被引:19
作者
Kazakauskaite, Egle [1 ]
Husmann, Lars [1 ]
Stehli, Julia [1 ]
Fuchs, Tobias [1 ]
Fiechter, Michael [1 ,2 ]
Klaeser, Bernd [1 ]
Ghadri, Jelena R. [1 ]
Gebhard, Catherine [1 ]
Gaemperli, Oliver [1 ]
Kaufmann, Philipp A. [1 ,2 ]
机构
[1] Univ Zurich Hosp, CH-8091 Zurich, Switzerland
[2] Univ Zurich, Zurich Ctr Integrat Human Physiol ZIHP, Zurich, Switzerland
基金
瑞士国家科学基金会;
关键词
High-definition computed tomography; Coronary angiography; Image quality; Radiation dose; BODY-MASS INDEX; ARTERY-DISEASE; PROGNOSTIC VALUE; HEART-RATE; 1ST EXPERIENCE; ATHEROSCLEROSIS; FEASIBILITY; POPULATION; PREDICTION; MANAGEMENT;
D O I
10.1007/s10554-012-0100-y
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A new generation of high definition computed tomography (HDCT) 64-slice devices complemented by a new iterative image reconstruction algorithm-adaptive statistical iterative reconstruction, offer substantially higher resolution compared to standard definition CT (SDCT) scanners. As high resolution confers higher noise we have compared image quality and radiation dose of coronary computed tomography angiography (CCTA) from HDCT versus SDCT. Consecutive patients (n = 93) underwent HDCT, and were compared to 93 patients who had previously undergone CCTA with SDCT matched for heart rate (HR), HR variability and body mass index (BMI). Tube voltage and current were adapted to the patient's BMI, using identical protocols in both groups. The image quality of all CCTA scans was evaluated by two independent readers in all coronary segments using a 4-point scale (1, excellent image quality; 2, blurring of the vessel wall; 3, image with artefacts but evaluative; 4, non-evaluative). Effective radiation dose was calculated from DLP multiplied by a conversion factor (0.014 mSv/mGy x cm). The mean image quality score from HDCT versus SDCT was comparable (2.02 +/- A 0.68 vs. 2.00 +/- A 0.76). Mean effective radiation dose did not significantly differ between HDCT (1.7 +/- A 0.6 mSv, range 1.0-3.7 mSv) and SDCT (1.9 +/- A 0.8 mSv, range 0.8-5.5 mSv; P = n.s.). HDCT scanners allow low-dose 64-slice CCTA scanning with higher resolution than SDCT but maintained image quality and equally low radiation dose. Whether this will translate into higher accuracy of HDCT for CAD detection remains to be evaluated.
引用
收藏
页码:471 / 477
页数:7
相关论文
共 28 条
[11]   Low-dose CT Coronary Angiography Using Prospective ECG-Triggering: Impact of Mean Heart Rate and Heart Rate Variability on Image Quality [J].
Herzog, Bernhard A. ;
Husmann, Lars ;
Burkhard, Nina ;
Valenta, Ines ;
Gaemperli, Oliver ;
Tatsugami, Fuminari ;
Wyss, Christophe A. ;
Landmesser, Ulf ;
Kaufmann, Philipp A. .
ACADEMIC RADIOLOGY, 2009, 16 (01) :15-21
[12]   Diagnostic Performance of High-Definition Coronary Computed Tomography Angiography Performed With Multiple Radiation Dose Reduction Strategies [J].
Heydari, Bobak ;
Leipsic, Jonathon ;
Mancini, G. B. John ;
Min, James K. ;
LaBounty, Troy ;
Taylor, C. ;
Freue, Gabriela V. Cohen ;
Heilbron, Brett .
CANADIAN JOURNAL OF CARDIOLOGY, 2011, 27 (05) :606-612
[13]  
Husmann L, 2008, EUR HEART J, V29, P191, DOI 10.1093/eurheartj/ehm613
[14]   Coronary artery motion and cardiac phases: Dependency on heart rate - Implications for CT image reconstruction [J].
Husmann, Lars ;
Leschka, Sebastian ;
Desbiolles, Lotus ;
Schepis, Tiziano ;
Gaemperli, Oliver ;
Seifert, Burkhardt ;
Cattin, Philippe ;
Frauenfelder, Thomas ;
Flohr, Thomas G. ;
Marincek, Borut ;
Kaufmann, Philipp A. ;
Alkadhi, Hatem .
RADIOLOGY, 2007, 245 (02) :567-576
[15]   Low-Dose Coronary CT Angiography With Prospective ECG Triggering: Validation of a Contrast Material Protocol Adapted to Body Mass Index [J].
Husmann, Lars ;
Herzog, Bernhard A. ;
Burkhard, Nina ;
Valenta, Ines ;
Burger, Irene A. ;
Gaemperli, Oliver ;
Kaufmann, Philipp A. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 193 (03) :802-806
[16]   Quantification of obstructive and nonobstructive coronary lesions by 64-slice computed tomography - A comparative study with quantitative coronary angiography and intravascular ultrasound [J].
Leber, AW ;
Knez, A ;
von Ziegler, F ;
Becker, A ;
Nikolaou, K ;
Paul, S ;
Wintersperger, B ;
Reiser, M ;
Becker, CR ;
Steinbeck, G ;
Boekstegers, P .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 46 (01) :147-154
[17]   Prognostic value of multidetector coronary computed tomographic angiography for prediction of all-cause mortality [J].
Min, James K. ;
Shaw, Leslee J. ;
Devereux, Richard B. ;
Okin, Peter M. ;
Weinsaft, Jonathan W. ;
Russo, Donald J. ;
Lippolis, Nicholas J. ;
Berman, Daniel S. ;
Callister, Tracy Q. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 50 (12) :1161-1170
[18]  
Min James K, 2009, J Cardiovasc Comput Tomogr, V3, P246, DOI 10.1016/j.jcct.2009.06.006
[19]   High-resolution spiral computed tomography coronary angiography in patients referred for diagnostic conventional coronary angiography [J].
Mollet, NR ;
Cademartiri, F ;
van Mieghem, CAG ;
Runza, G ;
McFadden, EP ;
Baks, T ;
Serruys, PW ;
Krestin, GP ;
de Feyter, PJ .
CIRCULATION, 2005, 112 (15) :2318-2323
[20]   Use of an automatic exposure control mechanism for dose optimization in multi-detector row CT examinations: Clinical evaluation [J].
Mulkens, TH ;
Bellinck, P ;
Baeyaert, M ;
Ghysen, D ;
Van Dijck, X ;
Mussen, E ;
Venstermans, C ;
Termote, JL .
RADIOLOGY, 2005, 237 (01) :213-223