Autologous fibrin sealant reduces the incidence of prolonged air leak and duration of chest tube drainage after lung volume reduction surgery: A prospective randomized blinded study

被引:53
作者
Moser, C. [1 ]
Opitz, I. [1 ]
Zhai, W. [1 ]
Rousson, V. [2 ]
Russi, E. W. [3 ]
Weder, W. [1 ]
Lardinois, D. [1 ]
机构
[1] Univ Zurich Hosp, Div Thorac Surg, CH-8091 Zurich, Switzerland
[2] Univ Zurich Hosp, Dept Biostat, CH-8091 Zurich, Switzerland
[3] Univ Zurich Hosp, Div Pneumol, CH-8091 Zurich, Switzerland
关键词
D O I
10.1016/j.jtcvs.2008.02.079
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Prolonged air leak is reported in up to 50% of patients after lung volume reduction surgery. The effect of an autologous fibrin sealant on the intensity and duration of air leak and on the time to chest drain removal after lung volume reduction surgery was investigated in a randomized prospective clinical trial. Methods: Twenty- five patients underwent bilateral thoracoscopic lung volume reduction surgery. In each patient, an autologous fibrin sealant was applied along the staple lines on one side, whereas no additional measure was taken on the other side. Randomization of treatment was performed at the end of the resection on the first side. Air leak was assessed semiquantitatively by use of a severity score (0 5 no leak; 4 5 continuous severe leak) by two investigators blinded to the treatment. Result: Mean value of the total severity scores for the first 48 hours postoperative was significantly lower in the treated group (4.7 +/- 7.7) than in the control group (16.0 +/- 10.1) (P < .001), independently of the length of the resection. Prolonged air leak and mean duration of drainage were also significantly reduced after application of the sealant (4.5% and 2.8 +/- 1.9 days versus 31.8% and 5.9 +/- 2.9 days) (P = .03 and P < .001). Conclusions: Autologous fibrin sealant for reinforcement of the staple lines after lung volume reduction surgery significantly reduces prolonged air leak and duration of chest tube drainage.
引用
收藏
页码:843 / 849
页数:7
相关论文
共 27 条
[1]   Prospective randomized study evaluating a biodegradable polymeric sealant for sealing intraoperative air leaks that occur during pulmonary resection [J].
Allen, MS ;
Wood, DE ;
Hawkinson, RW ;
Harpole, DH ;
McKenna, RJ ;
Walsh, GL ;
Vallieres, E ;
Miller, DL ;
Nichols, FC ;
Smythe, WR ;
Davis, RD .
ANNALS OF THORACIC SURGERY, 2004, 77 (05) :1792-1801
[2]   Efficiency of fleece-bound seating (TachoSil®) of air leaks in lung surgery:: a prospective randornised trial [J].
Anegg, Udo ;
Matzi, Veronika ;
Smolle, Josef ;
Maier, Alfred ;
Smolle-Juettner, Freyja .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2007, 31 (02) :198-202
[3]   The effect of autologous fibrin sealant (Vivostat®) on morbidity after pulmonary lobectomy:: a prospective randomised, blinded study [J].
Belboul, A ;
Dernevik, L ;
Aljassim, O ;
Skrbic, B ;
Radberg, G ;
Roberts, D .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2004, 26 (06) :1187-1191
[4]   Gain and subsequent loss of lung function after lung volume reduction surgery in cases of severe emphysema with different morphologic patterns [J].
Bloch, KE ;
Georgescu, CL ;
Russi, EW ;
Weder, W .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2002, 123 (05) :845-854
[5]   Predictors and treatment of persistent air leaks [J].
Cerfolio, RJ ;
Bass, CS ;
Pask, AH ;
Katholi, CR .
ANNALS OF THORACIC SURGERY, 2002, 73 (06) :1727-1730
[6]   Results of 150 consecutive bilateral lung volume reduction procedures in patients with severe emphysema [J].
Cooper, JD ;
Patterson, GA ;
Sundaresan, RS ;
Trulock, EP ;
Yusen, RD ;
Pohl, MS ;
Lefrak, SS .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1996, 112 (05) :1319-1329
[7]   Patient and surgical factors influencing air leak after lung volume reduction surgery: Lessons learned from the National Emphysema Treatment Trial [J].
DeCamp, Malcolm M. ;
Blackstone, Eugene H. ;
Naunheim, Keith S. ;
Krasna, Mark J. ;
Wood, Douglas E. ;
Meli, Yvonne M. ;
McKenna, Robert J., Jr. .
ANNALS OF THORACIC SURGERY, 2006, 82 (01) :197-207
[8]   Fibrin glue in pulmonary resection: A prospective, randomized, blinded study [J].
Fabian, T ;
Federico, JA ;
Ponn, RB .
ANNALS OF THORACIC SURGERY, 2003, 75 (05) :1587-1592
[9]  
Fishman A, 2003, NEW ENGL J MED, V348, P2059
[10]   EFFECT OF ROUTINE FIBRIN GLUE USE ON THE DURATION OF AIR LEAKS AFTER LOBECTOMY [J].
FLEISHER, AG ;
EVANS, KG ;
NELEMS, B ;
FINLEY, RJ .
ANNALS OF THORACIC SURGERY, 1990, 49 (01) :133-134