Study on cold head structure of a 300 Hz thermoacoustically driven pulse tube cryocooler

被引:8
作者
Yu, G. Y. [1 ]
Wang, X. T. [1 ]
Dai, W. [1 ]
Luo, E. C. [1 ]
机构
[1] Chinese Acad Sci, Key Lab Cryogen, Tech Inst Phys & Chem, Beijing 100190, Peoples R China
基金
中国国家自然科学基金;
关键词
High frequency; Standing wave thermoacoustic heat engine; Pulse tube cryocooler; Cold head structure; REFRIGERATOR; ENGINE;
D O I
10.1016/j.cryogenics.2012.01.010
中图分类号
O414.1 [热力学];
学科分类号
摘要
High reliability, compact size and potentially high thermal efficiency make the high frequency thermoacoustically-driven pulse tube cryocooler quite promising for space use. With continuous efforts, the lowest temperature and the thermal efficiency of the coupled system have been greatly improved. So far, a cold head temperature below 60 K has been achieved on such kind of cryocooler with the operation frequency of around 300 Hz. To further improve the thermal efficiency and expedite its practical application, this work focuses on studying the influence of cold head structure on the system performance. Substantial numerical simulations were firstly carried out, which revealed that the cold head structure would greatly influence the cooling power and the thermal efficiency. To validate the predictions, a lot of experiments have been done. The experiments and calculations are in reasonable agreement. With 500 W heating power input into the engine, a no-load temperature of 63 K and a cooling power of 1.16 W at 80 K have been obtained with parallel-plate cold head, indicating encouraging improvement of the thermal efficiency. (c) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:212 / 215
页数:4
相关论文
共 13 条
  • [1] [Anonymous], 2004, LABV 7 1 US MAN
  • [2] A thermoacoustic Stirling heat engine
    Backhaus, S
    Swift, GW
    [J]. NATURE, 1999, 399 (6734) : 335 - 338
  • [3] A 300 Hz two-stage pulse tube cryocooler that attains 58 K
    Cai, Huikun
    Yang, Luwei
    Luo, Ercang
    Zhou, Yuan
    [J]. CRYOGENICS, 2010, 50 (08) : 469 - 471
  • [4] 300 Hz thermoacoustically driven pulse tube cooler for temperature below 100 K
    Dai, Wei
    Yu, Guoyao
    Zhu, Shanglong
    Luo, Ercang
    [J]. APPLIED PHYSICS LETTERS, 2007, 90 (02)
  • [5] Detailed study of a traveling wave thermoacoustic refrigerator driven by a traveling wave thermoacoustic engine
    Dai, Wei
    Luo, Ercang
    Zhang, Yong
    Ling, Hong
    [J]. JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2006, 119 (05) : 2686 - 2692
  • [6] Godshalk KM, 1996, ADV CRYOG ENG, P1411
  • [7] Development of high efficiency Stirling-type pulse tube cryocoolers
    Hu, J. Y.
    Dai, W.
    Luo, E. C.
    Wang, X. T.
    Huang, Y.
    [J]. CRYOGENICS, 2010, 50 (09) : 603 - 607
  • [8] Radebaugh R., 1986, ADV CRYOGEN ENG, V31, P779
  • [9] Radebaugh Ray, 2005, ADV CRYOGEN ENG, V51, P1919
  • [10] Swift GW, 2017, Thermoacoustics: a unifying perspective for some engines and refrigerators