Carrier-based dry powder inhalation: Impact of carrier modification on capsule filling processability and in vitro aerodynamic performance

被引:40
作者
Faulhammer, Eva [1 ,2 ]
Wahl, Verena [1 ,2 ]
Zellnitz, Sarah [2 ]
Khinast, Johannes G. [1 ,2 ]
Paudel, Amrit [2 ]
机构
[1] Graz Univ Technol, Inst Proc & Particle Engn, A-8010 Graz, Austria
[2] Res Ctr Pharmaceut Engn, A-8010 Graz, Austria
关键词
Dry powder inhalers (DPI); Powder aerosols; Carrier decantation; Fine particle fraction; Dosator capsule filling; PULMONARY DRUG-DELIVERY; SALBUTAMOL SULFATE; ENGINEERED MANNITOL; MATERIAL ATTRIBUTES; PROCESS PARAMETERS; INHALER; SURFACE; FORMULATIONS; PARTICLES; EXCIPIENT;
D O I
10.1016/j.ijpharm.2015.06.044
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
This study aims to investigate the effect of carrier characteristics and dosator capsule filling operation on the in vitro deposition of mixtures containing salbutamol sulphate (SS) and lactose and mannitol as model carrier materials. The carrier surfaces of lactose and mannitol were modified via wet decantation. The impact of the decantation process on the properties of carriers was investigated by laser diffraction, density and powder flow measurements, N-2 physisorption, small and wide angle X-ray scattering (SWAXS) and scanning electron microscopy (SEM). Differences in carrier type and untreated and decanted materials were identified and the SAXS measurements proved to be a promising technology confirming the successful removal of fines. Adhesive carrier API mixtures with carrier-to-API ratio of 99:1 wt% were prepared, mixture homogeneity was tested and subsequently the mixtures were filled into capsules at different process settings. Finally, the influence of the decantation process on the in vitro performance of the adhesive mixtures was tested with a next generation impactor. For lactose, the decantation decreased the fine particle fraction (FPF) of SS, whereas the FPF of mannitol as a carrier was only affected by the capsule filling process. In summary, the DPI formulation based on untreated lactose, especially by capsule filling using a dosing chamber to powder layer (compression) ratio of 1:2, proved to be superior in terms of the dosing accuracy (RSD < 0.8%) and the in vitro aerodynamic performance (FPF of 12%). (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:231 / 242
页数:12
相关论文
共 34 条
[1]  
[Anonymous], 1982, Small angle x-ray scattering, DOI DOI 10.1002/ACTP.1985.010360520
[2]  
Ashurst I, 2000, Pharm Sci Technol Today, V3, P246, DOI 10.1016/S1461-5347(00)00275-3
[3]   Accuracy of micro powder dosing via a vibratory sieve-chute system [J].
Besenhard, M. O. ;
Faulhammer, E. ;
Fathollahi, S. ;
Reif, G. ;
Calzolari, V. ;
Biserni, S. ;
Ferrari, A. ;
Lawrence, S. M. ;
Llusa, M. ;
Khinast, J. G. .
EUROPEAN JOURNAL OF PHARMACEUTICS AND BIOPHARMACEUTICS, 2015, 94 :264-272
[4]   Influence of carrier surface fines on dry powder inhalation formulations [J].
Boshhiha, Antesar M. ;
Urbanetz, Nora A. .
DRUG DEVELOPMENT AND INDUSTRIAL PHARMACY, 2009, 35 (08) :904-916
[5]   Capabilities and limitations of using powder rheology and permeability to predict dry powder inhaler performance [J].
Cordts, Eike ;
Steckel, Hartwig .
EUROPEAN JOURNAL OF PHARMACEUTICS AND BIOPHARMACEUTICS, 2012, 82 (02) :417-423
[6]   Dry powder platform for pulmonary drug delivery [J].
Daniher, Derek Ivan ;
Zhu, Jesse .
PARTICUOLOGY, 2008, 6 (04) :225-238
[7]   Continued investigation into the influence of loaded dose on the performance of dry powder inhalers: Surface smoothing effects [J].
El-Sabawi, Dina ;
Edge, Stephen ;
Price, Robert ;
Young, Paul M. .
DRUG DEVELOPMENT AND INDUSTRIAL PHARMACY, 2006, 32 (10) :1135-1138
[8]  
Faulhammer E., 2015, DRUG DEV IND PHARM, P1, DOI DOI 10.3109/03639045.2015.1040416
[9]   Low-dose capsule filling of inhalation products: Critical material attributes and process parameters [J].
Faulhammer, Eva ;
Fink, Marlies ;
Llusa, Marcos ;
Lawrence, Simon M. ;
Biserni, Stefano ;
Calzolari, Vittorio ;
Khinast, Johannes G. .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2014, 473 (1-2) :617-626
[10]   The effects of material attributes on capsule fill weight and weight variability in dosator nozzle machines [J].
Faulhammer, Eva ;
Llusa, Marcos ;
Radeke, Charles ;
Scheibelhofer, Otto ;
Lawrence, Simon ;
Biserni, Stefano ;
Calzolari, Vittorio ;
Khinast, J. G. .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2014, 471 (1-2) :332-338