Estimation of Clinical Axial Extension of Class II Caries Lesions with Ultraspeed and Digital Radiographs: An In-vivo Study

被引:14
作者
Bin-Shuwaish, M. [1 ]
Dennison, J. B. [2 ]
Yaman, P. [3 ]
Neiva, G.
机构
[1] King Saud Univ, Coll Dent, Dept Restorat Dent Sci, Riyadh, Saudi Arabia
[2] Univ Michigan, Dept Cariol Restorat Sci & Endodont, Ann Arbor, MI 48109 USA
[3] Univ Michigan, Dept Cariol, Grad Restorat Dent Program, Ann Arbor, MI 48109 USA
关键词
D O I
10.2341/07-167
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This study compared the newly introduced direct digital radiographic (DDR) system (RVG-6000) with conventional bitewing radiographs (D-speed film) to estimate the extension of Class H caries lesions. The patient's discomfort related to placement of each radiographic packet was also evaluated. Fifty-one Class H caries lesions were selected. Affected teeth were radiographed with D-speed film and the RVG-6000 size 2 sensor. Patients were asked to complete a one-page questionnaire regarding discomfort during the radiographic examination. The true caries depth was validated clinically from intra.-operative photographs that captured the cross-sectional views of the lesion at its deepest point. During the operative procedures, the cavitation status was also recorded. A reference device was placed on the occlusal surface of the treatment or the adjacent tooth before taking radiographs and during the operative procedure. The caries lesion extension from the dentino-enamel junction (DEJ) was measured in mm on each radiograph and the results were compared to the true clinical depth. Both radiographs significantly underestimated the clinical depth (p<0.0001), but the RVG-6000 images were significantly closer to the actual depth of the lesion than the D-speed film (p=0.0031). All of the lesions which were diagnosed radiographically to be deeper than I nun into dentin were cavitated. Size, sharp edges of the sensor or both comprised the source(s) of most of the discomfort caused by D-speed film (64%) and RVG-6000 sensor (79%). The results of this study showed that both types of radiographic images tend to underestimate caries depth; however, the RVG-6000 image was more accurate than the D-speed film. This study also provides information about sources of the patient's discomfort associated with these radiographs.
引用
收藏
页码:613 / 621
页数:9
相关论文
共 21 条
[1]   Bitewing examination with four digital receptors [J].
Bahrami, G ;
Hagstrom, C ;
Wenzel, A .
DENTOMAXILLOFACIAL RADIOLOGY, 2003, 32 (05) :317-321
[2]   RADIOGRAPHIC DIAGNOSIS AND CLINICAL TISSUE CHANGES IN RELATION TO TREATMENT OF APPROXIMAL CARIOUS LESIONS [J].
BILLE, J ;
THYLSTRUP, A .
CARIES RESEARCH, 1982, 16 (01) :1-6
[3]  
Chong Michael J, 2003, Pediatr Dent, V25, P341
[4]   RADIOGRAPHIC VERSUS CLINICAL-DIAGNOSIS OF APPROXIMAL CARIOUS LESIONS [J].
DEVRIES, HCB ;
RUIKEN, HMHM ;
KONIG, KG ;
VANTHOF, MA .
CARIES RESEARCH, 1990, 24 (05) :364-370
[5]  
Erten H, 2005, QUINTESSENCE INT, V36, P65
[6]  
Güngör K, 2005, OPER DENT, V30, P58
[7]   SCREENING WITH CONVENTIONAL AND DIGITAL BITE-WING RADIOGRAPHY COMPARED TO CLINICAL EXAMINATION ALONE FOR CARIES DETECTION IN LOW-RISK CHILDREN [J].
HINTZE, H .
CARIES RESEARCH, 1993, 27 (06) :499-504
[8]   IN-VITRO COMPARISON OF D-SPEED AND E-SPEED FILM RADIOGRAPHY, RVG, AND VISUALIX DIGITAL RADIOGRAPHY FOR THE DETECTION OF ENAMEL APPROXIMAL AND DENTINAL OCCLUSAL CARIES LESIONS [J].
HINTZE, H ;
WENZEL, A ;
JONES, C .
CARIES RESEARCH, 1994, 28 (05) :363-367
[9]   Relationship between histological and radiographic caries lesion depth measured in images from four digital radiography systems [J].
Jacobsen, JH ;
Hansen, B ;
Wenzel, A ;
Hintze, H .
CARIES RESEARCH, 2004, 38 (01) :34-38
[10]  
Jessee Stephen A., 1999, General Dentistry, V47, P88