Matrix effects in human urine analysis using multi-targeted liquid chromatography-tandem mass spectrometry

被引:30
作者
Schlittenbauer, Linda [1 ]
Seiwert, Bettina [1 ]
Reemtsma, Thorsten [1 ]
机构
[1] UFZ Helmholtz Ctr Environm Res, Dept Analyt Chem, D-04318 Leipzig, Germany
关键词
Emerging contaminant; Human biomonitoring; Screening; SPE; SOLID-PHASE EXTRACTION; SAMPLE PREPARATION; SURFACE-WATER; WHOLE-BLOOD; DRUGS; PHARMACEUTICALS; METABOLITES; SORBENTS;
D O I
10.1016/j.chroma.2015.08.069
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Different sample preparation methods were tested for human urine for the subsequent analysis with a LC-MS/MS multimethod to quantify 65 micropollutants (pesticides, pharmaceuticals, personal care products, industrial chemicals and metabolites) within the general population. Direct injection of diluted urine revealed highly variable and often severe signal suppression for nearly all analytes at relevant concentration levels during electrospray ionization. Urine samples were highly variable in their total organic carbon (500-10,000 mg L-1) and creatinine (0.35-13 mM) content as well as in electrical conductivity (3-19 mS cm(-1)) but these differences did not correlate clearly with the strength of matrix effects. Therefore, matrix removal by solid phase extraction was intended and different mixed-mode sorbents were tested. Results showed poor apparent recoveries likely due to insufficient separation of target analytes and matrix compounds for all tested sorbents. The wide variability and high concentration levels of urine constituents strongly affect electrospray ionization as well as recovery during extraction at the submicrogram per liter level. Especially, the hydrophobic interaction at the hydrophilic-lipophilic-balanced sorbent was affected. It is concluded that the urine matrix is too strong, too diverse and too variable to allow one sample preparation method for the very diverse analytes of a LC-MS/MS multimethod. Instead dedicated methods appear more promising. (C) 2015 Published by Elsevier B.V.
引用
收藏
页码:91 / 99
页数:9
相关论文
共 27 条
[1]   Emerging organic contaminants in vertical subsurface flow constructed wetlands: Influence of media size, loading frequency and use of active aeration [J].
Avila, Cristina ;
Nivala, Jaime ;
Olsson, Linda ;
Kassa, Kinfe ;
Headley, Tom ;
Mueller, Roland A. ;
Maria Bayona, Josep ;
Garcia, Joan .
SCIENCE OF THE TOTAL ENVIRONMENT, 2014, 494 :211-217
[2]   Determination of opiates and cocaine in urine by high pH mobile phase reversed phase UPLC-MS/MS [J].
Berg, Thomas ;
Lundanes, Elsa ;
Christophersen, Asbjorg S. ;
Strand, Dag Helge .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (04) :421-432
[3]   The Human Urine Metabolome [J].
Bouatra, Souhaila ;
Aziat, Farid ;
Mandal, Rupasri ;
Guo, An Chi ;
Wilson, Michael R. ;
Knox, Craig ;
Bjorndahl, Trent C. ;
Krishnamurthy, Ramanarayan ;
Saleem, Fozia ;
Liu, Philip ;
Dame, Zerihun T. ;
Poelzer, Jenna ;
Huynh, Jessica ;
Yallou, Faizath S. ;
Psychogios, Nick ;
Dong, Edison ;
Bogumil, Ralf ;
Roehring, Cornelia ;
Wishart, David S. .
PLOS ONE, 2013, 8 (09)
[4]   Combined use of liquid chromatography-hybrid quadrupole time-of-flight mass spectrometry (LC-QTOF-MS) and high performance liquid chromatography with photodiode array detector (HPLC-DAD) in systematic toxicological analysis [J].
Broecker, Sebastian ;
Pragst, Fritz ;
Bakdash, Abdulsallam ;
Herre, Sieglinde ;
Tsokos, Michael .
FORENSIC SCIENCE INTERNATIONAL, 2011, 212 (1-3) :215-226
[5]   Single solid phase extraction method for the simultaneous analysis of polar and non-polar pesticides in urine samples by gas chromatography and ultra high pressure liquid chromatography coupled to tandem mass spectrometry [J].
Cazorla-Reyes, Rocio ;
Luis Fernandez-Moreno, Jose ;
Romero-Gonzalez, Roberto ;
Garrido Frenich, Antonia ;
Martinez Vidal, Jose Luis .
TALANTA, 2011, 85 (01) :183-196
[6]   Dilute-and-shoot-liquid chromatography-mass spectrometry for urine analysis in doping control and analytical toxicology [J].
Deventer, K. ;
Pozo, O. J. ;
Verstraete, A. G. ;
Van Eenoo, P. .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2014, 55 :1-13
[7]   Preparation of urine samples prior to targeted or untargeted metabolomics mass-spectrometry analysis [J].
Fernandez-Peralbo, M. A. ;
Luque de Castro, M. D. .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2012, 41 :75-85
[8]   Mixed-mode ion-exchange polymeric sorbents: dual-phase materials that improve selectivity and capacity [J].
Fontanals, Nuria ;
Cormack, Peter A. G. ;
Marce, Rosa M. ;
Borrull, Francesc .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2010, 29 (07) :765-779
[9]  
Gracia-Lor E., 2014, ENVIRON SCI POLLUT R, P1
[10]   Anthropogenic organic micro-pollutants and pathogens in the urban water cycle: Assessment, barriers and risk communication (ASKURIS) [J].
Jekel M. ;
Ruhl A.S. ;
Meinel F. ;
Zietzschmann F. ;
Lima S.P. ;
Baur N. ;
Wenzel M. ;
Gnirß R. ;
Sperlich A. ;
Dünnbier U. ;
Böckelmann U. ;
Hummelt D. ;
Van Baar P. ;
Wode F. ;
Petersohn D. ;
Grummt T. ;
Eckhardt A. ;
Schulz W. ;
Heermann A. ;
Reemtsma T. ;
Seiwert B. ;
Schlittenbauer L. ;
Lesjean B. ;
Miehe U. ;
Remy C. ;
Stapf M. ;
Mutz D. .
Environmental Sciences Europe, 2013, 25 (01)