Modifying the size distribution of microbubble contrast agents for high-frequency subharmonic imaging

被引:16
作者
Shekhar, Himanshu [1 ]
Rychak, Joshua J. [2 ,3 ]
Doyley, Marvin M. [1 ]
机构
[1] Univ Rochester, Dept Elect & Comp Engn, Rochester, NY 14627 USA
[2] Targeson Inc, San Diego, CA 92121 USA
[3] Univ Calif San Diego, Dept Bioengn, San Diego, CA 92093 USA
关键词
nonlinear ultrasound imaging; subharmonic imaging; microbubble contrast agents; vasa vasorum imaging; atherosclerosis; PHOSPHOLIPID-ENCAPSULATED MICROBUBBLES; CODED EXCITATION; VASA VASORUM; ULTRASOUND; ATTENUATION; SENSITIVITY; SCATTERING;
D O I
10.1118/1.4813017
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Subharmonic imaging is of interest for high frequency (>10 MHz) nonlinear imaging, because it can specifically detect the response of ultrasound contrast agents (UCA). However, conventional UCA produce a weak subharmonic response at high frequencies, which limits the sensitivity of subharmonic imaging. We hypothesized that modifying the size distribution of the agent can enhance its high-frequency subharmonic response. The overall goal of this study was to investigate size-manipulated populations of the agent to determine the range of sizes that produce the strongest subharmonic response at high frequencies (in this case, 20 MHz). A secondary goal was to assess whether the number or the volume-weighted size distribution better represents the efficacy of the agent for high-frequency subharmonic imaging. Methods: The authors created six distinct agent size distributions from the native distribution of a commercially available UCA (Targestar-P (R)). The median (number-weighted) diameter of the native agent was 1.63 mu m, while the median diameters of the size-manipulated populations ranged from 1.35 to 2.99 mu m. The authors conducted acoustic measurements with native and size-manipulated agent populations to assess their subharmonic response to 20 MHz excitation (pulse duration 1.5 mu s, pressure amplitudes 100-398 kPa). Results: The results showed a considerable difference between the subharmonic response of the agent populations that were investigated. The subharmonic response peaked for the agent population with a median diameter of 2.15 mu m, which demonstrated a subharmonic signal that was 8 dB higher than the native agent. Comparing the subharmonic response of different UCA populations indicated that microbubbles with diameters between 1.3 and 3 mu m are the dominant contributors to the subharmonic response at 20 MHz. Additionally, a better correlation was observed between the subharmonic response of the agent and the number-weighted size-distribution (R-2 = 0.98) than with the volume-weighted size distribution (R-2 = 0.53). Conclusions: Modifying the size distribution of the agent appears to be a viable strategy to improve the sensitivity of high-frequency subharmonic imaging. In addition, when the size distribution of the UCA has not been suitably modified, the number-weighted size distribution is a useful parameter to accurately describe the efficacy of the agent for high-frequency subharmonic imaging. (C) 2013 American Association of Physicists in Medicine.
引用
收藏
页数:10
相关论文
共 50 条
[31]   Imaging of the Calf Vocal Fold With High-Frequency Ultrasound [J].
Walsh, Conor J. ;
Heaton, James T. ;
Kobler, James B. ;
Szabo, Thomas L. ;
Zeitels, Steven M. .
LARYNGOSCOPE, 2008, 118 (10) :1894-1899
[32]   Manufacture and acoustical characterisation of a high-frequency contrast agent for targeting applications [J].
Moran, CM ;
Ross, JA ;
Cunningham, C ;
Butler, M ;
Anderson, T ;
Newby, D ;
Fox, KAA ;
McDicken, WN .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2006, 32 (03) :421-428
[33]   Synthesis of ultrasound contrast agents: characteristics and size distribution analysis (secondary publication) [J].
Lee, Hak Jong ;
Yoon, Tae-Jong ;
Yoon, Young Il .
ULTRASONOGRAPHY, 2017, 36 (04) :378-384
[34]   A Multifunctional, Reconfigurable Pulse Generator for High-Frequency Ultrasound Imaging [J].
Qiu, Weibao ;
Yu, Yanyan ;
Tsang, Fu Keung ;
Sun, Lei .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2012, 59 (07) :1558-1567
[35]   CORONARY-ARTERY IMAGING WITH INTRAVASCULAR HIGH-FREQUENCY ULTRASOUND [J].
POTKIN, BN ;
BARTORELLI, AL ;
GESSERT, JM ;
NEVILLE, RF ;
ALMAGOR, Y ;
ROBERTS, WC ;
LEON, MB .
CIRCULATION, 1990, 81 (05) :1575-1585
[36]   High-frequency Ultrasound Imaging of Mouse Cervical Lymph Nodes [J].
Walk, Elyse L. ;
McLaughlin, Sarah L. ;
Weed, Scott A. .
JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2015, (101) :1-9
[37]   High-Frequency Ultrasound Imaging Findings for Different Breast Fillers [J].
Chai, Hongli ;
Zhuang, Jun ;
Su, Xueshang ;
Yuan, Li ;
Jia, Ying ;
Hu, Jintian .
AESTHETIC PLASTIC SURGERY, 2025,
[38]   A Practical Method for Extraction of High-Frequency Parameters of Distribution Cables [J].
Sabolic, Dubravko ;
Malaric, Roman ;
Bazant, Alen .
IEEE TRANSACTIONS ON POWER DELIVERY, 2012, 27 (04) :1877-1884
[39]   High-Frequency Energy Distribution of a Plasma Coated Paraboloid Reflector [J].
Shahzad, Muhammad H. ;
Ghaffar, Abdul ;
Naz, Muhammad Y. ;
Bhatti, Haq N. .
PROGRESS IN ELECTROMAGNETICS RESEARCH M, 2020, 92 :11-20
[40]   Plasmon-Resonant Gold Nanostars with Variable Size as Contrast Agents for Imaging Applications [J].
Bibikova O. ;
Popov A. ;
Bykov A. ;
Fales A. ;
Yuan H. ;
Skovorodkin I. ;
Kinnunen M. ;
Vainio S. ;
Vo-Dinh T. ;
Tuchin V.V. ;
Meglinski I. .
IEEE Journal of Selected Topics in Quantum Electronics, 2016, 22 (03) :13-20