Modifying the size distribution of microbubble contrast agents for high-frequency subharmonic imaging

被引:16
作者
Shekhar, Himanshu [1 ]
Rychak, Joshua J. [2 ,3 ]
Doyley, Marvin M. [1 ]
机构
[1] Univ Rochester, Dept Elect & Comp Engn, Rochester, NY 14627 USA
[2] Targeson Inc, San Diego, CA 92121 USA
[3] Univ Calif San Diego, Dept Bioengn, San Diego, CA 92093 USA
关键词
nonlinear ultrasound imaging; subharmonic imaging; microbubble contrast agents; vasa vasorum imaging; atherosclerosis; PHOSPHOLIPID-ENCAPSULATED MICROBUBBLES; CODED EXCITATION; VASA VASORUM; ULTRASOUND; ATTENUATION; SENSITIVITY; SCATTERING;
D O I
10.1118/1.4813017
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Subharmonic imaging is of interest for high frequency (>10 MHz) nonlinear imaging, because it can specifically detect the response of ultrasound contrast agents (UCA). However, conventional UCA produce a weak subharmonic response at high frequencies, which limits the sensitivity of subharmonic imaging. We hypothesized that modifying the size distribution of the agent can enhance its high-frequency subharmonic response. The overall goal of this study was to investigate size-manipulated populations of the agent to determine the range of sizes that produce the strongest subharmonic response at high frequencies (in this case, 20 MHz). A secondary goal was to assess whether the number or the volume-weighted size distribution better represents the efficacy of the agent for high-frequency subharmonic imaging. Methods: The authors created six distinct agent size distributions from the native distribution of a commercially available UCA (Targestar-P (R)). The median (number-weighted) diameter of the native agent was 1.63 mu m, while the median diameters of the size-manipulated populations ranged from 1.35 to 2.99 mu m. The authors conducted acoustic measurements with native and size-manipulated agent populations to assess their subharmonic response to 20 MHz excitation (pulse duration 1.5 mu s, pressure amplitudes 100-398 kPa). Results: The results showed a considerable difference between the subharmonic response of the agent populations that were investigated. The subharmonic response peaked for the agent population with a median diameter of 2.15 mu m, which demonstrated a subharmonic signal that was 8 dB higher than the native agent. Comparing the subharmonic response of different UCA populations indicated that microbubbles with diameters between 1.3 and 3 mu m are the dominant contributors to the subharmonic response at 20 MHz. Additionally, a better correlation was observed between the subharmonic response of the agent and the number-weighted size-distribution (R-2 = 0.98) than with the volume-weighted size distribution (R-2 = 0.53). Conclusions: Modifying the size distribution of the agent appears to be a viable strategy to improve the sensitivity of high-frequency subharmonic imaging. In addition, when the size distribution of the UCA has not been suitably modified, the number-weighted size distribution is a useful parameter to accurately describe the efficacy of the agent for high-frequency subharmonic imaging. (C) 2013 American Association of Physicists in Medicine.
引用
收藏
页数:10
相关论文
共 50 条
[21]   Concentration requirements for subharmonic quantitative contrast enhanced high frequency ultrasound flow studies [J].
Stapleton, Shawn A. ;
Needles, Andrew ;
Henderson, Emily ;
Foster, F. Stuart .
2007 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1-6, 2007, :1061-+
[22]   Frequency compounded imaging with a high-frequency dual element transducer [J].
Chang, Jin Ho ;
Kim, Hyung Ham ;
Lee, Jungwoo ;
Shung, K. Kirk .
ULTRASONICS, 2010, 50 (4-5) :453-457
[23]   Combined Perfusion and Doppler Imaging Using Plane-Wave Nonlinear Detection and Microbubble Contrast Agents [J].
Tremblay-Darveau, Charles ;
Williams, Ross ;
Milot, Laurent ;
Bruce, Matthew ;
Burns, Peter N. .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2014, 61 (12) :1988-2000
[24]   Microbubble contrast agents - Targeted ultrasound imaging and ultrasound-assisted drug-delivery applications [J].
Klibanov, AL .
INVESTIGATIVE RADIOLOGY, 2006, 41 (03) :354-362
[25]   High and low frequency subharmonic imaging of angiogenesis in a murine breast cancer model [J].
Dahibawkar, Manasi ;
Forsberg, Mark A. ;
Gupta, Aditi ;
Jaffe, Samantha ;
Dulin, Kelly ;
Eisenbrey, John R. ;
Halldorsdottir, Valgerdur G. ;
Forsberg, Anya I. ;
Dave, Jaydev K. ;
Marshall, Andrew ;
Machado, Priscilla ;
Fox, Traci B. ;
Liu, Ji-Bin ;
Forsberg, Flemming .
ULTRASONICS, 2015, 62 :50-55
[26]   Dual-Frequency Subharmonic Ultrasound Contrast Imaging for Non-Invasive Blood Pressure Measurement [J].
Spiekhout, Sander ;
Voorneveld, Jason ;
de Jong, Nico ;
Bosch, Johannes G. .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2025, 51 (05) :870-876
[27]   In vivo high-frequency contrast-enhanced ultrasonography of choroidal melanoma in rabbits: imaging features and histopathologic correlations [J].
Kang, Shin J. ;
Zhang, Qing ;
Patel, Samirkumar R. ;
Berezovsky, Damian ;
Yang, Hua ;
Wang, Yanggan ;
Grossniklaus, Hans E. .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2013, 97 (07) :929-933
[28]   In vivo contrast-enhanced high-frequency ultrasonography of experimental uveal melanoma: imaging features and histopathologic correlations [J].
Grossniklaus, Hans ;
Kang, Shin ;
Zhang, Qing .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
[29]   High-frequency, plane-wave, multi-pulse acoustic contrast agent imaging at 16 MHz [J].
Ketterling, Jeffrey A. ;
Silverman, Ronald H. .
2019 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2019, :2314-2317
[30]   HIGH-FREQUENCY ACOUSTIC IMPEDANCE IMAGING OF CANCER CELLS [J].
Fadhel, Muhannad N. ;
Berndl, Elizabeth S. L. ;
Strohm, Eric M. ;
Kolios, Michael C. .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2015, 41 (10) :2700-2713