Effects of Graft Thickness and Asymmetry on Visual Gain and Aberrations After Descemet Stripping Automated Endothelial Keratoplasty

被引:58
|
作者
Dickman, Mor M. [1 ]
Cheng, Yanny Y. Y. [1 ]
Berendschot, Tos T. J. M. [1 ]
van den Biggelaar, Frank J. H. M. [1 ]
Nuijts, Rudy M. M. A. [1 ]
机构
[1] Maastricht Univ, Med Ctr, Univ Eye Clin Maastricht, Maastricht, Netherlands
关键词
HIGHER-ORDER ABERRATIONS; ANTERIOR CORNEAL ABERRATIONS; OPTICAL COHERENCE TOMOGRAPHY; POSTERIOR SURFACE; PENETRATING KERATOPLASTY; CONFOCAL MICROSCOPY; LENTICULE THICKNESS; OCULUS PENTACAM; VISION; EYES;
D O I
10.1001/jamaophthalmol.2013.73
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Importance: Understanding the contribution of graft thickness and asymmetry to visual gain and posterior corneal (PC) higher-order aberrations (HOAs) may assist optimizing visual outcomes after Descemet stripping automated endothelial keratoplasty (DSAEK). Objective: To investigate the effects of graft thickness and asymmetry on visual gain and aberrations after DSAEK. Design: Retrospective analysis of an interventional case series of eyes undergoing DSAEK. Visual gain was defined as the difference between preoperative and 6-month postoperative best-corrected visual acuity in logMAR equivalents. Graft thickness was measured by anterior-segment optical coherence tomography. Corneal topography and HOAs were measured by Scheimpflug imaging. Raw posterior corneal (PC) elevation data were exported and fitted against a best-fitted sphere, providing a measure of donor lenticule asymmetry. Correlation analysis was performed among visual gain, graft thickness, graft asymmetry, and PC HOAs. Setting: University Eye Clinic Maastricht. Participants: Seventy-nine eyes with corneal endothelial dysfunction. Exposure: All patients underwent DSEAK. Main Outcomes and Measures: Visual gain, graft thickness, graft asymmetry, and PC HOAs. Results: Mean best-corrected visual acuity improved from 0.63 logMAR equivalents preoperatively to 0.25 logMAR equivalents postoperatively (P < .001). Mean (SD) graft thickness of the series was 97 (25) (range, 39-145) mu m. After excluding patients with vision-limiting comorbidities, visual gain significantly correlated with graft thickness (r = -0.35[P = .02]). This correlation was strongest in patients with pseudophakic bullous keratopathy (r= -0.62 [P = .01]). Graft thickness significantly correlated with graft asymmetry in the 4- and 6-mm zones (r= 0.32 [P = .007] and r= 0.32 [P = .006], respectively), which in turn correlated with all but spherical PC HOAs. Conclusions and Relevance: After DSAEK, visual gain shows a significant correlation with graft thickness in patients without vision-limiting comorbidities. This relationship is strongest in patients with pseudophakic bullous keratopathy. Graft thickness also correlates with graft asymmetry, which in turn correlates with all but spherical PC HOAs. These findings may assist surgeons in choosing DSAEK graft thickness and shape, particularly in eyes without vision-limiting comorbidities. Further randomized trials are needed to investigate the relationship between graft thickness and visual gain after DSAEK.
引用
收藏
页码:737 / 744
页数:8
相关论文
共 50 条
  • [2] Impact of graft thickness on visual gain after Descemet's stripping automated endothelial keratoplasty.
    Sot, Maxime
    Lhuillier, Louis
    Houmad, Naila
    Zaidi, Mohamed
    Ehrhardt, Alix
    Guechi, Oualid
    Agapie, Adina
    Krawczyk, Piotr
    Ouamara, Nadia
    Perone, Jean-Marc
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [3] Graft Thickness, Graft Folds, and Aberrations After Descemet Stripping Endothelial Keratoplasty for Fuchs Dystrophy
    Seery, Loren S.
    Nau, Cherie B.
    McLaren, Jay W.
    Baratz, Keith H.
    Patel, Sanjay V.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2011, 152 (06) : 910 - 916
  • [4] Graft Detachment After Descemet Stripping Automated Endothelial keratoplasty
    Cardascia, Nicola
    La Tegola, Gabriella
    Pastore, Valentina
    Bini, Vito
    Alessio, Giovanni
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [5] Impact of graft thickness on visual acuity after Descemet's stripping endothelial keratoplasty
    Shinton, Anthony J.
    Tsatsos, Michael
    Konstantopoulos, Aris
    Goverdhan, Srini
    Elsahn, Ahmad F.
    Anderson, David F.
    Hossain, Parwez
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2012, 96 (02) : 246 - 249
  • [6] Descemet Membrane Endothelial Keratoplasty as Treatment for Graft Failure After Descemet Stripping Automated Endothelial Keratoplasty
    Weller, Julia M.
    Tourtas, Theofilos
    Kruse, Friedrich E.
    Schloetzer-Schrehardt, Ursula
    Fuchsluger, Thomas
    Bachmann, Bjoern O.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2015, 159 (06) : 1050 - 1057
  • [7] Outcome of Descemet membrane endothelial keratoplasty for graft failure after Descemet stripping automated endothelial keratoplasty
    Agha, Bishr
    Shajari, Mehdi
    Slavik-Lencova, Anna
    Kohnen, Thomas
    Schmack, Ingo
    CLINICAL OPHTHALMOLOGY, 2019, 13 : 553 - 559
  • [8] Outcomes of rebubbling for graft detachment after Descemet's stripping endothelial keratoplasty or Descemet's stripping automated endothelial keratoplasty
    Bhalerao, Sushank A.
    Mohamed, Ashik
    Vaddavalli, Pravin K.
    Murthy, Somasheila, I
    Reddy, Jagadesh C.
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2020, 68 (01) : 48 - 53
  • [9] Refractive outcomes after descemet stripping automated endothelial keratoplasty surgery associated with graft thickness
    Cheung, Natalie
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [10] Effect of Donor Graft Thickness on Clinical Outcomes after Descemet Stripping Automated Endothelial Keratoplasty
    Feizi, Sepehr
    Javadi, Mohammad Ali
    JOURNAL OF OPHTHALMIC & VISION RESEARCH, 2019, 14 (01) : 18 - 26