Evaluation of myopic corneal diameter with the Orbscan II Topography System

被引:24
作者
Zha, Yi [1 ]
Feng, Wangqiang [1 ]
Han, Xiaohui [1 ]
Cai, Jianqiu [1 ]
机构
[1] Wenzhou Med Coll, Affiliated Hosp 2, Wenzhou, Zhejiang, Peoples R China
关键词
Cornea; Diameter; Orbscan II; Myopia; ANTERIOR-CHAMBER DIAMETER; DEPTH; EYE;
D O I
10.1007/s00417-012-2069-6
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
To assess the myopic corneal diameter with Orbscan II Topography System (Bausch & Lomb, Orbtek Inc., Salt Lake City, UT, USA). Four hundred sixty-two eyes of 231 myopic patients and 129 emmetropic eyes were measured with the Orbscan II system. Eyes were divided into four groups according to the spherical equivalent(SE) as follows: group 1 [emmetropic group, spherical equivalents between -0.50 D and +0.50 D (-0.50 < SE a parts per thousand currency signaEuro parts per thousand+0.50)]; group 2 [low myopia group, spherical equivalent between -0.50 D and -3.00D (-3.00 < SE a parts per thousand currency signaEuro parts per thousand a'0.50)]; group 3 [median myopia group, spherical equivalent between -3.00 and -6.00D (-6.00 < SE a parts per thousand currency signaEuro parts per thousand a'3.00)]; and group 4 [high myopia group, spherical equivalents of -6.00D or less (a parts per thousand currency signa'6.00)]. Manifest refraction results and the Orbscan II corneal topographic maps were reviewed retrospectively. Horizontal corneal diameters (white-to-white [WTW] distance) were measured with the Orbscan II system. Subjects in different groups were matched to be comparable in terms of spherical equivalents. The corneal diameter in all myopic eyes was 11.49 +/- 0.36 mm. There were no significant differences between right and left eyes in the t-test for paired samples (t = -0.119, P = 0.906). Differences among four groups proved to be significant in the ANOVA (F = 4.487, P = 0.004). This article provides a detailed description and analysis of Orbscan II corneal diameter of a normal myopic population. High degree of mirror image symmetry existed in myopic corneal diameter. Spherical equivalents made a difference in corneal diameter.
引用
收藏
页码:537 / 541
页数:5
相关论文
共 20 条
[11]  
Riordan-Eva P, 2001, GEN OPHTHALMOLOGY, P8
[12]  
Rüfer F, 2005, CORNEA, V24, P259
[13]   Myopia in Singapore: taking a public health approach [J].
Seet, B ;
Wong, TY ;
Tan, DTH ;
Saw, SM ;
Balakrishnan, V ;
Lee, LKH ;
Lin, ASM .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2001, 85 (05) :521-526
[14]   Effects of White-to-White Diameter and Anterior Chamber Depth on Implantable Collamer Lens Vault and Visual Outcome [J].
Seo, Je Hyun ;
Kim, Mee Kum ;
Wee, Won Ryang ;
Lee, Jin Hak .
JOURNAL OF REFRACTIVE SURGERY, 2009, 25 (08) :730-738
[15]  
Srivannaboon Sabong, 2005, Journal of the Medical Association of Thailand, V88, P1222
[16]  
Starck T, 2000, PRINCIPLES PRACTICE, p[695, 3618]
[17]  
Wang L, 2002, DEV OPHTHALMOL, V34, P141
[18]   Evaluation of orbscan II corneal topography in individuals with myopia [J].
Wei, RH ;
Lim, L ;
Chan, WK ;
Tan, DTH .
OPHTHALMOLOGY, 2006, 113 (02) :177-183
[19]   Correlation between different measurements within the eye relative to phakic intraocular lens implantation [J].
Werner, L ;
Izak, AM ;
Pandey, SK ;
Apple, DJ ;
Trivedi, RH ;
Schmidbauer, JM .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (09) :1982-1988
[20]  
Zhang H, 2005, CHINESE OPHTHALMOLOG, P89