Evaluation of myopic corneal diameter with the Orbscan II Topography System

被引:24
作者
Zha, Yi [1 ]
Feng, Wangqiang [1 ]
Han, Xiaohui [1 ]
Cai, Jianqiu [1 ]
机构
[1] Wenzhou Med Coll, Affiliated Hosp 2, Wenzhou, Zhejiang, Peoples R China
关键词
Cornea; Diameter; Orbscan II; Myopia; ANTERIOR-CHAMBER DIAMETER; DEPTH; EYE;
D O I
10.1007/s00417-012-2069-6
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
To assess the myopic corneal diameter with Orbscan II Topography System (Bausch & Lomb, Orbtek Inc., Salt Lake City, UT, USA). Four hundred sixty-two eyes of 231 myopic patients and 129 emmetropic eyes were measured with the Orbscan II system. Eyes were divided into four groups according to the spherical equivalent(SE) as follows: group 1 [emmetropic group, spherical equivalents between -0.50 D and +0.50 D (-0.50 < SE a parts per thousand currency signaEuro parts per thousand+0.50)]; group 2 [low myopia group, spherical equivalent between -0.50 D and -3.00D (-3.00 < SE a parts per thousand currency signaEuro parts per thousand a'0.50)]; group 3 [median myopia group, spherical equivalent between -3.00 and -6.00D (-6.00 < SE a parts per thousand currency signaEuro parts per thousand a'3.00)]; and group 4 [high myopia group, spherical equivalents of -6.00D or less (a parts per thousand currency signa'6.00)]. Manifest refraction results and the Orbscan II corneal topographic maps were reviewed retrospectively. Horizontal corneal diameters (white-to-white [WTW] distance) were measured with the Orbscan II system. Subjects in different groups were matched to be comparable in terms of spherical equivalents. The corneal diameter in all myopic eyes was 11.49 +/- 0.36 mm. There were no significant differences between right and left eyes in the t-test for paired samples (t = -0.119, P = 0.906). Differences among four groups proved to be significant in the ANOVA (F = 4.487, P = 0.004). This article provides a detailed description and analysis of Orbscan II corneal diameter of a normal myopic population. High degree of mirror image symmetry existed in myopic corneal diameter. Spherical equivalents made a difference in corneal diameter.
引用
收藏
页码:537 / 541
页数:5
相关论文
共 20 条
[1]   Pupil Size, White-to-White Corneal Diameter, and Anterior Chamber Depth in Patients With Myopia [J].
Alfonso, Jose F. ;
Ferrer-Blasco, Teresa ;
Gonzalez-Meijome, Jose M. ;
Garcia-Manjarres, M. ;
Peixoto-de-Matos, Sofia C. ;
Montes-Mico, Robert .
JOURNAL OF REFRACTIVE SURGERY, 2010, 26 (11) :891-898
[2]   Comparison of manual and automated methods to determine horizontal corneal diameter [J].
Baumeister, M ;
Terzi, E ;
Ekici, Y ;
Kohnen, T .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (02) :374-380
[3]  
Duke-Elder S., 1961, SYSTEM OPHTHALMOLOGY, VII, P92
[4]  
Edwards MH, 2004, ANN ACAD MED SINGAP, V33, P34
[5]   White-to-White Corneal Diameter in the Tehran Eye Study [J].
Hashemi, Hassan ;
KhabazKhoob, Mehdi ;
Yazdani, Kamran ;
Mehravaran, Shiva ;
Mohammad, Kazem ;
Fotouhi, Akbar .
CORNEA, 2010, 29 (01) :9-12
[6]   Clinical results using the Holladay 2 intraocular lens power formula [J].
Hoffer, KJ .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2000, 26 (08) :1233-1237
[7]   Relationship between ciliary sulcus diameter and anterior chamber diameter and corneal diameter [J].
Kawamorita, Takushi ;
Uozato, Hiroshi ;
Kamiya, Kazutaka ;
Shimizu, Kimiya .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (04) :617-624
[8]   Evaluation of the relationship between corneal diameter and lens diameter [J].
Khng, Christopher ;
Osher, Robert H. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (03) :475-479
[9]   Internal anterior chamber diameter using optical coherence tomography compared with white-to-white distances using automated measurements [J].
Kohnen, Thomas ;
Thomala, Martin Christian ;
Cichocki, Magdalena ;
Strenger, Anja .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (11) :1809-1813
[10]  
Müller A, 2002, OPTOMETRY VISION SCI, V79, P762, DOI 10.1097/00006324-200212000-00008